Repeatability or test–retest reliability is the closeness of the agreement between the results of successive measurements of the same measure , when carried out under the same conditions of measurement. In other words, the measurements are taken by a single person or instrument on the same item, under the same conditions, and in a short period of time. A less-than-perfect test–retest reliability causes test–retest variability . Such variability can be caused by, for example, intra-individual variability and inter-observer variability . A measurement may be said to be repeatable when this variation is smaller than a predetermined acceptance criterion.

#928071

30-457: Test–retest variability is practically used, for example, in medical monitoring of conditions. In these situations, there is often a predetermined "critical difference", and for differences in monitored values that are smaller than this critical difference, the possibility of variability as a sole cause of the difference may be considered in addition to, for example, changes in diseases or treatments. The following conditions need to be fulfilled in

60-404: A central ICU monitoring station, where a single staff member can observe and respond to several bedside monitors simultaneously. Ambulatory telemetry can also be achieved by portable, battery-operated models which are carried by the patient and which transmit their data via a wireless data connection. Digital monitoring has created the possibility, which is being fully developed, of integrating

90-415: A critical difference of 40%. In a clinical laboratory, a delta check is a laboratory quality control method that compares a current test result with previous test results of the same person, and detects whether there is a substantial difference, as can be defined as a critical difference as per previous section, or defined by other pre-defined criteria. If the difference exceeds the pre-defined criteria,

120-428: A monitor to a distant monitoring station is known as telemetry or biotelemetry . Monitoring can be classified by the target of interest, including: Monitoring of vital parameters can include several of the ones mentioned above, and most commonly include at least blood pressure and heart rate , and preferably also pulse oximetry and respiratory rate . Multimodal monitors that simultaneously measure and display

150-525: A patient has a hemoglobin level of 100 g/L, the analytical variation ( CV a ) is 1.8% and the intra-individual variability CV i is 2.2%, then the critical difference is 8.1 g/L. Thus, for changes of less than 8 g/L since a previous test, the possibility that the change is completely caused by test-retest variability may need to be considered in addition to considering effects of, for example, diseases or treatments. Critical differences for other tests include early morning urinary albumin concentration, with

180-594: A patient's blood pressure , while another would measure pulse oximetry , another the ECG. Later analog models had a second or third channel displayed on the same screen, usually to monitor respiration movements and blood pressure . These machines were widely used and saved many lives, but they had several restrictions, including sensitivity to electrical interference , base level fluctuations and absence of numeric readouts and alarms. Several models of multi-parameter monitors are networkable, i.e., they can send their output to

210-412: A probability of 95%. The standard deviation under repeatability conditions is part of precision and accuracy . An attribute agreement analysis is designed to simultaneously evaluate the impact of repeatability and reproducibility on accuracy. It allows the analyst to examine the responses from multiple reviewers as they look at several scenarios multiple times. It produces statistics that evaluate

240-591: Is a medical device used for monitoring. It can consist of one or more sensors , processing components, display devices (which are sometimes in themselves called "monitors"), as well as communication links for displaying or recording the results elsewhere through a monitoring network. Sensors of medical monitors include biosensors and mechanical sensors. For example, photodiode is used in pulse oximetry, Pressure sensor used in Non Invasive blood pressure measurement. The translating component of medical monitors

270-403: Is equipped with sub-systems for the purpose of maintaining balance and self healing functions. Intervention without sufficient data might damage those healing sub systems. Monitoring medicine fills the gap to prevent diagnosis errors and can assist in future medical research by analyzing all data of many patients. The development cycle in medicine is extremely long, up to 20 years, because of

300-455: Is quite probably true for many physical measurements. However, this argument is often inappropriate for psychological measurement, because it is often impossible to consider the second administration of a test a parallel measure to the first. The second administration of a psychological test might yield systematically different scores than the first administration due to the following reasons: Medical monitoring In medicine, monitoring

330-486: Is responsible for converting the signals from the sensors to a format that can be shown on the display device or transferred to an external display or recording device. Physiological data are displayed continuously on a CRT , LED or LCD screen as data channels along the time axis. They may be accompanied by numerical readouts of computed parameters on the original data, such as maximum, minimum and average values, pulse and respiratory frequencies, and so on. Besides

SECTION 10

#1732793805929

360-432: Is the observation of a disease, condition or one or several medical parameters over time. It can be performed by continuously measuring certain parameters by using a medical monitor (for example, by continuously measuring vital signs by a bedside monitor), and/or by repeatedly performing medical tests (such as blood glucose monitoring with a glucose meter in people with diabetes mellitus ). Transmitting data from

390-430: The ability of the appraisers to agree with themselves (repeatability), with each other ( reproducibility ), and with a known master or correct value (overall accuracy) for each characteristic – over and over again. Because the same test is administered twice and every test is parallel with itself, differences between scores on the test and scores on the retest should be due solely to measurement error. This sort of argument

420-510: The anaesthetist throughout anaesthesia A. Induction and maintenance of anaesthesia 1. Pulse oximeter 2. Non-invasive blood pressure monitoring 3. Inspired and expired oxygen, carbon dioxide, nitrous oxide and vapour 4. Airway pressure 5. A nerve stimulator whenever a muscle relaxant is used 6. Temperature (pre-op) and for any procedure >30 min anaesthesia duration B. Recovery from anaesthesia 1. Pulse oximeter 2. Non-invasive blood pressure monitor 3. Electrocardiograph 4. Capnograph if

450-469: The charts. Medical monitor's embedded software can take care of the data coding according to these standards and send messages to the medical records application, which decodes them and incorporates the data into the adequate fields. Long-distance connectivity can avail for telemedicine , which involves provision of clinical health care at a distance. A medical monitor can also have the function to produce an alarm (such as using audible signals) to alert

480-429: The clinical status of an individual. For example, the parameter of oxygen saturation is usually monitored to detect changes in respiratory capability of an individual. When monitoring a clinical parameters, differences between test results (or values of a continuously monitored parameter after a time interval) can reflect either (or both) an actual change in the status of the condition or a test-retest variability of

510-562: The cutoffs are used, and hence, different cutoffs are often used at different departments even in the same hospital. The development of new techniques for monitoring is an advanced and developing field in smart medicine , biomedical-aided integrative medicine , alternative medicine , self-tailored preventive medicine and predictive medicine that emphasizes monitoring of comprehensive medical data of patients, people at risk and healthy people using advanced, smart, minimally invasive biomedical devices , biosensors , lab-on-a-chip (in

540-436: The enormous damage medications can cause, researchers are working to fulfill the need for a comprehensive further study and personal continuous clinical monitoring of health conditions while keeping legacy medical intervention as a last resort. In many medical problems, drugs offer temporary relief of symptoms while the root of a medical problem remains unknown without enough data of all our biological systems . Our body

570-482: The establishment of repeatability: Repeatability methods were developed by Bland and Altman (1986). If the correlation between separate administrations of the test is high (e.g. 0.7 or higher as in this Cronbach's alpha-internal consistency-table ), then it has good test–retest reliability. The repeatability coefficient is a precision measure which represents the value below which the absolute difference between two repeated test results may be expected to lie with

600-478: The future nanomedicine devices like nanorobots ) and advanced computerized medical diagnosis and early warning tools over a short clinical interview and drug prescription . As biomedical research , nanotechnology and nutrigenomics advances, realizing the human body's self-healing capabilities and the growing awareness of the limitations of medical intervention by chemical drugs -only approach of old school medical treatment, new researches that shows

630-755: The need for U.S. Food and Drug Administration (FDA) approvals, therefore many of monitoring medicine solutions are not available today in conventional medicine. Minimum acceptable monitoring 1. Clinical observation (one-to-one) 2. Pulse oximetry 3. Non-invasive blood pressure 4. ECG 5. Core temperature 6. End-tidal carbon dioxide (if tracheal tube or supraglottic airway device in situ) Additional monitoring which should be immediately available 1. Blood/capillary glucose 2. Nerve stimulator Additional monitoring which should be available 1. Urine output 2. Invasive pressure monitoring (arterial line, central venous pressure) 3. Cardiac output monitoring 4. Access to haematological and biochemical investigations Presence of

SECTION 20

#1732793805929

660-538: The patient has a tracheal tube or supraglottic airway device in situ, or is deeply sedated 5. Temperature C. Additional monitoring 1. Some patients will require additional monitoring: e.g. intravascular pressures, cardiac output. 2. Depth of anaesthesia monitors recommended when patients are anaesthetised with total intravenous techniques. D. Regional techniques & sedation for operative procedures 1. Pulse oximeter 2. Non-invasive blood pressure monitoring 3. Electrocardiograph 4. End-tidal carbon dioxide monitor if

690-469: The patient is sedated. Display device A display device is an output device for presentation of information in visual or tactile form (the latter used for example in tactile electronic displays for blind people). When the input information that is supplied has an electrical signal the display is called an electronic display . Common applications for electronic visual displays are television sets or computer monitors . These are

720-513: The physiological data from the patient monitoring networks into the emerging hospital electronic health record and digital charting systems, using appropriate health care standards which have been developed for this purpose by organizations such as IEEE and HL7 . This newer method of charting patient data reduces the likelihood of human documentation error and will eventually reduce overall paper consumption. In addition, automated ECG interpretation incorporates diagnostic codes automatically into

750-554: The relevant vital parameters are commonly integrated into the bedside monitors in critical care units , and the anesthetic machines in operating rooms . These allow for continuous monitoring of a patient, with medical staff being continuously informed of the changes in general condition of a patient. Some monitors can even warn of pending fatal cardiac conditions before visible signs are noticeable to clinical staff, such as atrial fibrillation or premature ventricular contraction (PVC). A medical monitor or physiological monitor

780-421: The result is reported only after manual confirmation by laboratory personnel, in order to exclude a laboratory error as a cause of the difference. In order to flag samples as deviating from previously, the exact cutoff values are chosen to give a balance between sensitivity and the risk of being overwhelmed by false-positive flags. This balance, in turn, depends on the different kinds of clinical situations where

810-447: The staff when certain criteria are set, such as when some parameter exceeds of falls the level limits. An entirely new scope is opened with mobile carried monitors, even such in sub-skin carriage. This class of monitors delivers information gathered in body-area networking ( BAN ) to e.g. smart phones and implemented autonomous agents . Monitoring of clinical parameters is primarily intended to detect changes (or absence of changes) in

840-707: The technologies used to create the various displays in use today. Some displays can show only digits or alphanumeric characters. They are called segment displays , because they are composed of several segments that switch on and off to give appearance of desired glyph . The segments are usually single LEDs or liquid crystals . They are mostly used in digital watches and pocket calculators . Common types are seven-segment displays which are used for numerals only, and alphanumeric fourteen-segment displays and sixteen-segment displays which can display numerals and Roman alphabet letters. Cathode-ray tubes were also formerly widely used. 2-dimensional displays that cover

870-476: The test method. In practice, the possibility that a difference is due to test-retest variability can almost certainly be excluded if the difference is larger than a predefined "critical difference". This "critical difference" (CD) is calculated as: C D = K × C V a 2 + C V i 2 {\displaystyle CD=K\times {\sqrt {CV_{a}^{2}+CV_{i}^{2}}}} , where: For example, if

900-657: The tracings of physiological parameters along time (X axis), digital medical displays have automated numeric readouts of the peak and/or average parameters displayed on the screen. Modern medical display devices commonly use digital signal processing (DSP), which has the advantages of miniaturization , portability , and multi-parameter displays that can track many different vital signs at once. Old analog patient displays, in contrast, were based on oscilloscopes , and had one channel only, usually reserved for electrocardiographic monitoring ( ECG ). Therefore, medical monitors tended to be highly specialized. One monitor would track