In biochemistry , ABTS ( 2,2'-azino-bis(3-ethylbenzothiazoline-6-sulfonic acid) ) is a chemical compound used to observe the reaction kinetics of specific enzymes . A common use for it is in the enzyme-linked immunosorbent assay (ELISA) to detect the binding of molecules to each other.
79-438: It is commonly used as a substrate with hydrogen peroxide for a peroxidase enzyme (such as horseradish peroxidase ) or alone with blue multicopper oxidase enzymes (such as laccase or bilirubin oxidase ). Its use allows the reaction kinetics of peroxidases themselves to be followed. In this way it also can be used to indirectly follow the reaction kinetics of any hydrogen peroxide -producing enzyme, or to simply quantify
158-406: A ceramic material) (3) oscillates the cantilever (1). The sharp tip (4) is fixed to the free end of the cantilever (1). The detector (5) records the deflection and motion of the cantilever (1). The sample (6) is mounted on the sample stage (8). An xyz drive (7) permits to displace the sample (6) and the sample stage (8) in x, y, and z directions with respect to the tip apex (4). Although Fig. 3 shows
237-421: A constant amplitude of the cantilever oscillation as long as there is no drift or interaction with the surface. The interaction of forces acting on the cantilever when the tip comes close to the surface, van der Waals forces , dipole–dipole interactions , electrostatic forces , etc. cause the amplitude of the cantilever's oscillation to change (usually decrease) as the tip gets closer to the sample. This amplitude
316-451: A constant probe-sample interaction (see § Topographic image for more). The surface topography is commonly displayed as a pseudocolor plot. Although the initial publication about atomic force microscopy by Binnig, Quate and Gerber in 1986 speculated about the possibility of achieving atomic resolution, profound experimental challenges needed to be overcome before atomic resolution of defects and step edges in ambient (liquid) conditions
395-425: A few picometers. The van der Waals forces , which are strongest from 1 nm to 10 nm above the surface, or any other long-range force that extends above the surface acts to decrease the resonance frequency of the cantilever. This decrease in resonant frequency combined with the feedback loop system maintains a constant oscillation amplitude or frequency by adjusting the average tip-to-sample distance. Measuring
474-412: A given metabolic pathway in clinical DDI studies. Metabolism by the same cytochrome P450 isozyme can result in several clinically significant drug-drug interactions. Atomic force microscopy Atomic force microscopy ( AFM ) or scanning force microscopy ( SFM ) is a very-high-resolution type of scanning probe microscopy (SPM), with demonstrated resolution on the order of fractions of
553-404: A hardness of cells, and to evaluate interactions between a specific cell and its neighboring cells in a competitive culture system. AFM can also be used to indent cells, to study how they regulate the stiffness or shape of the cell membrane or wall. In some variations, electric potentials can also be scanned using conducting cantilevers. In more advanced versions, currents can be passed through
632-409: A material stuck on the tip of the cantilever, and from another hand the surface of particles either free or occupied by the same material. From the adhesion force distribution curve, a mean value of the forces has been derived. It allowed to make a cartography of the surface of the particles, covered or not by the material. AFM has also been used for mechanically unfolding proteins. In such experiments,
711-496: A nanometer, more than 1000 times better than the optical diffraction limit . Atomic force microscopy (AFM) is a type of SPM, with demonstrated resolution on the order of fractions of a nanometer, more than 1000 times better than the optical diffraction limit . The information is gathered by "feeling" or "touching" the surface with a mechanical probe. Piezoelectric elements that facilitate tiny but accurate and precise movements on (electronic) command enable precise scanning. Despite
790-431: A property termed enzyme promiscuity . An enzyme may have many native substrates and broad specificity (e.g. oxidation by cytochrome p450s ) or it may have a single native substrate with a set of similar non-native substrates that it can catalyse at some lower rate. The substrates that a given enzyme may react with in vitro , in a laboratory setting, may not necessarily reflect the physiological, endogenous substrates of
869-406: A quantitative manner from phase images, however, is often not feasible. In non-contact atomic force microscopy mode, the tip of the cantilever does not contact the sample surface. The cantilever is instead oscillated at either its resonant frequency (frequency modulation) or just above (amplitude modulation) where the amplitude of oscillation is typically a few nanometers (<10 nm) down to
SECTION 10
#1732783285579948-633: A single atom) has also been achieved by AFM. In manipulation, the forces between tip and sample can also be used to change the properties of the sample in a controlled way. Examples of this include atomic manipulation, scanning probe lithography and local stimulation of cells. Simultaneous with the acquisition of topographical images, other properties of the sample can be measured locally and displayed as an image, often with similarly high resolution. Examples of such properties are mechanical properties like stiffness or adhesion strength and electrical properties such as conductivity or surface potential. In fact,
1027-442: A substrate is called 'fluorogenic' if it gives rise to a fluorescent product when acted on by an enzyme. For example, curd formation ( rennet coagulation) is a reaction that occurs upon adding the enzyme rennin to milk. In this reaction, the substrate is a milk protein (e.g., casein ) and the enzyme is rennin. The products are two polypeptides that have been formed by the cleavage of the larger peptide substrate. Another example
1106-451: Is a topographic image. In other words, the topographic image is a trace of the tip of the probe regulated so that the df is constant and it may also be considered to be a plot of a constant-height surface of the df. Therefore, the topographic image of the AFM is not the exact surface morphology itself, but actually the image influenced by the bond-order between the probe and the sample, however,
1185-436: Is also frequently used by the food industry and agricultural researchers to measure the antioxidant capacities of foods. In this assay, ABTS is converted to its radical cation by addition of sodium persulfate . This radical cation is blue in color and absorbs light at 415, 645, 734 and 815 nm. The ABTS radical cation is reactive towards most antioxidants including phenolics , thiols and Vitamin C . During this reaction,
1264-433: Is chosen because the enzyme facilitates the reaction with hydrogen peroxide, turning it into a green and soluble end-product. Its new absorbance maximum of 420 nm light (ε = 3.6 × 10 M cm) can easily be followed with a spectrophotometer , a common laboratory instrument. It is sometimes used as part of a glucose estimating reagent when finding glucose concentrations of solutions such as blood serum . ABTS
1343-410: Is commonly achieved with a small piezo element in the cantilever holder, but other possibilities include an AC magnetic field (with magnetic cantilevers), piezoelectric cantilevers, or periodic heating with a modulated laser beam. The amplitude of this oscillation usually varies from several nm to 200 nm. In tapping mode, the frequency and amplitude of the driving signal are kept constant, leading to
1422-404: Is gentle enough even for the visualization of supported lipid bilayers or adsorbed single polymer molecules (for instance, 0.4 nm thick chains of synthetic polyelectrolytes ) under liquid medium. With proper scanning parameters, the conformation of single molecules can remain unchanged for hours, and even single molecular motors can be imaged while moving. When operating in tapping mode,
1501-442: Is needed. By applying a small dither to the tip, the stiffness (force gradient) of the bond can be measured as well. Force spectroscopy is used in biophysics to measure the mechanical properties of living material (such as tissue or cells) or detect structures of different stiffness buried into the bulk of the sample using the stiffness tomography. Another application was to measure the interaction forces between from one hand
1580-751: Is not an endogenous, in vivo substrate for FAAH. In another example, the N -acyl taurines (NATs) are observed to increase dramatically in FAAH-disrupted animals, but are actually poor in vitro FAAH substrates. Sensitive substrates also known as sensitive index substrates are drugs that demonstrate an increase in AUC of ≥5-fold with strong index inhibitors of a given metabolic pathway in clinical drug-drug interaction (DDI) studies. Moderate sensitive substrates are drugs that demonstrate an increase in AUC of ≥2 to <5-fold with strong index inhibitors of
1659-427: Is the chemical decomposition of hydrogen peroxide carried out by the enzyme catalase . As enzymes are catalysts , they are not changed by the reactions they carry out. The substrate(s), however, is/are converted to product(s). Here, hydrogen peroxide is converted to water and oxygen gas. While the first (binding) and third (unbinding) steps are, in general, reversible , the middle step may be irreversible (as in
SECTION 20
#17327832855791738-422: Is used as the parameter that goes into the electronic servo that controls the height of the cantilever above the sample. The servo adjusts the height to maintain a set cantilever oscillation amplitude as the cantilever is scanned over the sample. A tapping AFM image is therefore produced by imaging the force of the intermittent contacts of the tip with the sample surface. Although the peak forces applied during
1817-433: Is vibrated or oscillated at a given frequency. AFM operation is usually described as one of three modes, according to the nature of the tip motion: contact mode, also called static mode (as opposed to the other two modes, which are called dynamic modes); tapping mode, also called intermittent contact, AC mode, or vibrating mode, or, after the detection mechanism, amplitude modulation AFM; and non-contact mode, or, again after
1896-409: The phase of oscillation can be used to discriminate between different types of materials on the surface. Amplitude modulation can be operated either in the non-contact or in the intermittent contact regime. In dynamic contact mode, the cantilever is oscillated such that the separation distance between the cantilever tip and the sample surface is modulated. Amplitude modulation has also been used in
1975-433: The AFM tip is extended towards and retracted from the surface as the deflection of the cantilever is monitored as a function of piezoelectric displacement. These measurements have been used to measure nanoscale contacts, atomic bonding , Van der Waals forces , and Casimir forces , dissolution forces in liquids and single molecule stretching and rupture forces. AFM has also been used to measure, in an aqueous environment,
2054-422: The amount of hydrogen peroxide in a sample. The formal reduction potentials for ABTS are high enough for it to act as an electron donor for the reduction of oxo species such as molecular oxygen and hydrogen peroxide, particularly at the less-extreme pH values encountered in biological catalysis. Under these conditions, the sulfonate groups are fully deprotonated and the mediator exists as a dianion. This compound
2133-433: The antioxidant capacity of food products. For example, polyphenol compounds, which widely exist in fruit, can quench free radicals inside human body, thus prevent oxidative damage by free radicals. The antioxidant potency of plant extract or food product has been measured by ABTS assay. One example with detailed method is the antioxidant activity analysis of Hibiscus products. Substrate (biochemistry) In chemistry ,
2212-440: The beam (by creating a vacuum) and staining the sample are not necessary. There are several types of scanning microscopy including SPM (which includes AFM, scanning tunneling microscopy (STM) and near-field scanning optical microscope (SNOM/NSOM), STED microscopy (STED), and scanning electron microscopy and electrochemical AFM , EC-AFM). Although SNOM and STED use visible , infrared or even terahertz light to illuminate
2291-515: The blue ABTS radical cation is converted back to its colorless neutral form. The reaction may be monitored spectrophotometrically. This assay is often referred to as the Trolox equivalent antioxidant capacity (TEAC) assay. The reactivity of the various antioxidants tested are compared to that of Trolox , which is a water-soluble analog of vitamin E . Based on the special chemical properties of formed free radicals, ABTS assay has been used to determine
2370-410: The case of more than one substrate, these may bind in a particular order to the active site, before reacting together to produce products. A substrate is called 'chromogenic' if it gives rise to a coloured product when acted on by an enzyme. In histological enzyme localization studies, the colored product of enzyme action can be viewed under a microscope, in thin sections of biological tissues. Similarly,
2449-399: The case of rigid samples, contact and non-contact images may look the same. However, if a few monolayers of adsorbed fluid are lying on the surface of a rigid sample, the images may look quite different. An AFM operating in contact mode will penetrate the liquid layer to image the underlying surface, whereas in non-contact mode an AFM will oscillate above the adsorbed fluid layer to image both
ABTS - Misplaced Pages Continue
2528-414: The concavity and convexity accompanied with a scan of the sample along x–y direction (without height regulation in z-direction). As a result, the frequency shift arises. The image in which the values of the frequency obtained by a raster scan along the x–y direction of the sample surface are plotted against the x–y coordination of each measurement point is called a constant-height image. On the other hand,
2607-413: The contacting part of the oscillation can be much higher than typically used in contact mode, tapping mode generally lessens the damage done to the surface and the tip compared to the amount done in contact mode. This can be explained by the short duration of the applied force, and because the lateral forces between tip and sample are significantly lower in tapping mode over contact mode. Tapping mode imaging
2686-505: The deflection (displacement with respect to the equilibrium position) of the cantilever and converts it into an electrical signal. The intensity of this signal will be proportional to the displacement of the cantilever. Various methods of detection can be used, e.g. interferometry, optical levers, the piezoelectric method, and STM-based detectors (see section "AFM cantilever deflection measurement"). This section applies specifically to imaging in § Contact mode . For other imaging modes,
2765-415: The deflection even when scanning in constant force mode, with feedback. This reveals the small tracking error of the feedback, and can sometimes reveal features that the feedback was not able to adjust for. The AFM signals, such as sample height or cantilever deflection, are recorded on a computer during the x–y scan. They are plotted in a pseudocolor image, in which each pixel represents an x–y position on
2844-404: The deflection of the cantilever is recorded as a function of the sample x–y position. As long as the tip is in contact with the sample, the deflection then corresponds to surface topography. This method is now less commonly used because the forces between tip and sample are not controlled, which can lead to forces high enough to damage the tip or the sample. It is, however, common practice to record
2923-409: The detection mechanism, frequency modulation AFM. Despite the nomenclature, repulsive contact can occur or be avoided both in amplitude modulation AFM and frequency modulation AFM, depending on the settings. In contact mode, the tip is "dragged" across the surface of the sample and the contours of the surface are measured either using the deflection of the cantilever directly or, more commonly, using
3002-420: The detector. The first one (using z-Feedback loop), said to be "constant XX mode" ( XX is something which kept by z-Feedback loop). Topographic image formation mode is based on abovementioned "constant XX mode", z-Feedback loop controls the relative distance between the probe and the sample through outputting control signals to keep constant one of frequency, vibration and phase which typically corresponds to
3081-417: The df may be kept constant by moving the probe upward and downward (See (3) of FIG.5) in z-direction using a negative feedback (by using z-feedback loop) while the raster scan of the sample surface along the x–y direction. The image in which the amounts of the negative feedback (the moving distance of the probe upward and downward in z-direction) are plotted against the x–y coordination of each measurement point
3160-407: The dispersion force due to polymer adsorbed on the substrate. Forces of the order of a few piconewtons can now be routinely measured with a vertical distance resolution of better than 0.1 nanometers. Force spectroscopy can be performed with either static or dynamic modes. In dynamic modes, information about the cantilever vibration is monitored in addition to the static deflection. Problems with
3239-458: The distance along the z axis between the probe support (2 in fig. 3) and the sample support (8 in fig 3). As long as the tip remains in contact with the sample, and the sample is scanned in the x–y plane, height variations in the sample will change the deflection of the cantilever. The feedback then adjusts the height of the probe support so that the deflection is restored to a user-defined value (the setpoint). A properly adjusted feedback loop adjusts
ABTS - Misplaced Pages Continue
3318-471: The drive attached to the sample, the drive can also be attached to the tip, or independent drives can be attached to both, since it is the relative displacement of the sample and tip that needs to be controlled. Controllers and plotter are not shown in Fig. 3. According to the configuration described above, the interaction between tip and sample, which can be an atomic-scale phenomenon, is transduced into changes of
3397-432: The enzyme's reactions in vivo . That is to say that enzymes do not necessarily perform all the reactions in the body that may be possible in the laboratory. For example, while fatty acid amide hydrolase (FAAH) can hydrolyze the endocannabinoids 2-arachidonoylglycerol (2-AG) and anandamide at comparable rates in vitro , genetic or pharmacological disruption of FAAH elevates anandamide but not 2-AG, suggesting that 2-AG
3476-399: The feedback signal required to keep the cantilever at a constant position. Because the measurement of a static signal is prone to noise and drift, low stiffness cantilevers (i.e. cantilevers with a low spring constant, k) are used to achieve a large enough deflection signal while keeping the interaction force low. Close to the surface of the sample, attractive forces can be quite strong, causing
3555-613: The field of solid state physics include (a) the identification of atoms at a surface, (b) the evaluation of interactions between a specific atom and its neighboring atoms, and (c) the study of changes in physical properties arising from changes in an atomic arrangement through atomic manipulation. In molecular biology, AFM can be used to study the structure and mechanical properties of protein complexes and assemblies. For example, AFM has been used to image microtubules and measure their stiffness. In cellular biology, AFM can be used to attempt to distinguish cancer cells and normal cells based on
3634-456: The first few subsections below. In three of the most common nano-scale microscopy techniques, atomic force microscopy (AFM), scanning tunneling microscopy (STM), and transmission electron microscopy (TEM), a substrate is required for sample mounting. Substrates are often thin and relatively free of chemical features or defects. Typically silver, gold, or silicon wafers are used due to their ease of manufacturing and lack of interference in
3713-422: The frequency modulation mode allows for the use of very stiff cantilevers. Stiff cantilevers provide stability very close to the surface and, as a result, this technique was the first AFM technique to provide true atomic resolution in ultra-high vacuum conditions. In amplitude modulation, changes in the oscillation amplitude or phase provide the feedback signal for imaging. In amplitude modulation, changes in
3792-402: The intensity of a value as a hue. Usually, the correspondence between the intensity of a value and a hue is shown as a color scale in the explanatory notes accompanying the image. Operation mode of image forming of the AFM are generally classified into two groups from the viewpoint whether it uses z-Feedback loop (not shown) to maintain the tip-sample distance to keep signal intensity exported by
3871-480: The liquid and surface. Schemes for dynamic mode operation include frequency modulation where a phase-locked loop is used to track the cantilever's resonance frequency and the more common amplitude modulation with a servo loop in place to keep the cantilever excitation to a defined amplitude. In frequency modulation, changes in the oscillation frequency provide information about tip-sample interactions. Frequency can be measured with very high sensitivity and thus
3950-406: The majority of SPM techniques are extensions of AFM that use this modality. The major difference between atomic force microscopy and competing technologies such as optical microscopy and electron microscopy is that AFM does not use lenses or beam irradiation. Therefore, it does not suffer from a limitation in spatial resolution due to diffraction and aberration, and preparing a space for guiding
4029-553: The microscopy data. Samples are deposited onto the substrate in fine layers where it can act as a solid support of reliable thickness and malleability. Smoothness of the substrate is especially important for these types of microscopy because they are sensitive to very small changes in sample height. Various other substrates are used in specific cases to accommodate a wide variety of samples. Thermally-insulating substrates are required for AFM of graphite flakes for instance, and conductive substrates are required for TEM. In some contexts,
SECTION 50
#17327832855794108-514: The motion of cantilever (for instance, voltage is applied to the Z-piezoelectric element and it moves the sample up and down towards the Z direction. When the distance between the probe and the sample is brought to the range where atomic force may be detected, while a cantilever is excited in its natural eigenfrequency ( f 0 ), the resonance frequency f of the cantilever may shift from its original resonance frequency. In other words, in
4187-399: The motion of cantilever, which is a macro-scale phenomenon. Several different aspects of the cantilever motion can be used to quantify the interaction between the tip and sample, most commonly the value of the deflection, the amplitude of an imposed oscillation of the cantilever, or the shift in resonance frequency of the cantilever (see section Imaging Modes). The detector (5) of AFM measures
4266-547: The name, the Atomic Force Microscope does not use the Nuclear force . The AFM has three major abilities: force measurement, topographic imaging, and manipulation. In force measurement, AFMs can be used to measure the forces between the probe and the sample as a function of their mutual separation. This can be applied to perform force spectroscopy , to measure the mechanical properties of the sample, such as
4345-469: The non-contact regime to image with atomic resolution by using very stiff cantilevers and small amplitudes in an ultra-high vacuum environment. Image formation is a plotting method that produces a color mapping through changing the x–y position of the tip while scanning and recording the measured variable, i.e. the intensity of control signal, to each x–y coordinate. The color mapping shows the measured value corresponding to each coordinate. The image expresses
4424-432: The phase of the cantilever's oscillation with respect to the driving signal can be recorded as well. This signal channel contains information about the energy dissipated by the cantilever in each oscillation cycle. Samples that contain regions of varying stiffness or with different adhesion properties can give a contrast in this channel that is not visible in the topographic image. Extracting the sample's material properties in
4503-450: The process is similar, except that "deflection" should be replaced by the appropriate feedback variable. When using the AFM to image a sample, the tip is brought into contact with the sample, and the sample is raster scanned along an x–y grid (fig 4). Most commonly, an electronic feedback loop is employed to keep the probe-sample force constant during scanning. This feedback loop has the cantilever deflection as input, and its output controls
4582-432: The range where atomic force may be detected, a frequency shift ( df = f – f 0 ) will also be observed. When the distance between the probe and the sample is in the non-contact region, the frequency shift increases in negative direction as the distance between the probe and the sample gets smaller. When the sample has concavity and convexity, the distance between the tip-apex and the sample varies in accordance with
4661-413: The reaction of interest, but they frequently bind the reagents with some affinity to allow sticking to the substrate. The substrate is exposed to different reagents sequentially and washed in between to remove excess. A substrate is critical in this technique because the first layer needs a place to bind to such that it is not lost when exposed to the second or third set of reagents. In biochemistry ,
4740-476: The rennin and catalase reactions just mentioned) or reversible (e.g. many reactions in the glycolysis metabolic pathway). By increasing the substrate concentration, the rate of reaction will increase due to the likelihood that the number of enzyme-substrate complexes will increase; this occurs until the enzyme concentration becomes the limiting factor . Although enzymes are typically highly specific, some are able to perform catalysis on more than one substrate,
4819-604: The resulting data collection. Silicon substrates are also commonly used because of their cost-effective nature and relatively little data interference in X-ray collection. Single-crystal substrates are useful in powder diffraction because they are distinguishable from the sample of interest in diffraction patterns by differentiating by phase. In atomic layer deposition , the substrate acts as an initial surface on which reagents can combine to precisely build up chemical structures. A wide variety of substrates are used depending on
SECTION 60
#17327832855794898-402: The sample's Young's modulus , a measure of stiffness. For imaging, the reaction of the probe to the forces that the sample imposes on it can be used to form an image of the three-dimensional shape (topography) of a sample surface at a high resolution. This is achieved by raster scanning the position of the sample with respect to the tip and recording the height of the probe that corresponds to
4977-431: The sample, and the color represents the recorded signal. The AFM was invented by IBM scientists in 1985. The precursor to the AFM, the scanning tunneling microscope (STM), was developed by Gerd Binnig and Heinrich Rohrer in the early 1980s at IBM Research – Zurich , a development that earned them the 1986 Nobel Prize for Physics . Binnig invented the atomic force microscope and the first experimental implementation
5056-406: The sample, their resolution is not constrained by the diffraction limit. Fig. 3 shows an AFM, which typically consists of the following features. Numbers in parentheses correspond to numbered features in Fig. 3. Coordinate directions are defined by the coordinate system (0). The small spring-like cantilever (1) is carried by the support (2). Optionally, a piezoelectric element (typically made of
5135-431: The substrate is a molecule upon which an enzyme acts. Enzymes catalyze chemical reactions involving the substrate(s). In the case of a single substrate, the substrate bonds with the enzyme active site , and an enzyme-substrate complex is formed. The substrate is transformed into one or more products , which are then released from the active site. The active site is then free to accept another substrate molecule. In
5214-464: The substrate is the chemical of interest that is being modified. In biochemistry , an enzyme substrate is the material upon which an enzyme acts. When referring to Le Chatelier's principle , the substrate is the reagent whose concentration is changed. In the latter sense, it may refer to a surface on which other chemical reactions are performed or play a supporting role in a variety of spectroscopic and microscopic techniques, as discussed in
5293-463: The support-sample separation continuously during the scanning motion, such that the deflection remains approximately constant. In this situation, the feedback output equals the sample surface topography to within a small error. Historically, a different operation method has been used, in which the sample-probe support distance is kept constant and not controlled by a feedback ( servo mechanism ). In this mode, usually referred to as "constant-height mode",
5372-433: The surface presents a major problem for contact mode in ambient conditions. Dynamic contact mode (also called intermittent contact, AC mode or tapping mode) was developed to bypass this problem. Nowadays, tapping mode is the most frequently used AFM mode when operating in ambient conditions or in liquids. In tapping mode , the cantilever is driven to oscillate up and down at or near its resonance frequency. This oscillation
5451-420: The technique include no direct measurement of the tip-sample separation and the common need for low-stiffness cantilevers, which tend to "snap" to the surface. These problems are not insurmountable. An AFM that directly measures the tip-sample separation has been developed. The snap-in can be reduced by measuring in liquids or by using stiffer cantilevers, but in the latter case a more sensitive deflection sensor
5530-433: The term substrate is highly context-dependent. Broadly speaking, it can refer either to a chemical species being observed in a chemical reaction , or to a surface on which other chemical reactions or microscopy are performed. In the former sense, a reagent is added to the substrate to generate a product through a chemical reaction. The term is used in a similar sense in synthetic and organic chemistry , where
5609-522: The tip is brought into proximity of a sample surface, forces between the tip and the sample lead to a deflection of the cantilever according to Hooke's law . Depending on the situation, forces that are measured in AFM include mechanical contact force, van der Waals forces , capillary forces , chemical bonding , electrostatic forces , magnetic forces (see magnetic force microscope , MFM), Casimir forces , solvation forces , etc. Along with force, additional quantities may simultaneously be measured through
5688-405: The tip to "snap-in" to the surface. Thus, contact mode AFM is almost always done at a depth where the overall force is repulsive, that is, in firm "contact" with the solid surface. In ambient conditions, most samples develop a liquid meniscus layer. Because of this, keeping the probe tip close enough to the sample for short-range forces to become detectable while preventing the tip from sticking to
5767-422: The tip to probe the electrical conductivity or transport of the underlying surface, but this is a challenging task with few research groups reporting consistent data (as of 2004). The AFM consists of a cantilever with a sharp tip (probe) at its end that is used to scan the specimen surface. The cantilever is typically silicon or silicon nitride with a tip radius of curvature on the order of nanometers. When
5846-419: The tip-to-sample distance at each (x,y) data point allows the scanning software to construct a topographic image of the sample surface. Non-contact mode AFM does not suffer from tip or sample degradation effects that are sometimes observed after taking numerous scans with contact AFM. This makes non-contact AFM preferable to contact AFM for measuring soft samples, e.g. biological samples and organic thin film. In
5925-412: The topographic image of the AFM is considered to reflect the geographical shape of the surface more than the topographic image of a scanning tunnel microscope. Besides imaging, AFM can be used for force spectroscopy , the direct measurement of tip-sample interaction forces as a function of the gap between the tip and sample. The result of this measurement is called a force-distance curve. For this method,
6004-401: The use of specialized types of probes (see scanning thermal microscopy , scanning joule expansion microscopy , photothermal microspectroscopy , etc.). The AFM can be operated in a number of modes, depending on the application. In general, possible imaging modes are divided into static (also called contact ) modes and a variety of dynamic (non-contact or "tapping") modes where the cantilever
6083-436: The word substrate can be used to refer to the sample itself, rather than the solid support on which it is placed. Various spectroscopic techniques also require samples to be mounted on substrates, such as powder diffraction . This type of diffraction, which involves directing high-powered X-rays at powder samples to deduce crystal structures, is often performed with an amorphous substrate such that it does not interfere with
6162-422: Was demonstrated in 1993 by Ohnesorge and Binnig. True atomic resolution of the silicon 7x7 surface—the atomic images of this surface obtained by STM had convinced the scientific community of the spectacular spatial resolution of scanning tunneling microscopy—had to wait a little longer before it was shown by Giessibl. Subatomic resolution (i.e. the ability to resolve structural details within the electron density of
6241-558: Was made by Binnig, Quate and Gerber in 1986. The first commercially available atomic force microscope was introduced in 1989. The AFM is one of the foremost tools for imaging, measuring, and manipulating matter at the nanoscale . The AFM has been applied to problems in a wide range of disciplines of the natural sciences, including solid-state physics , semiconductor science and technology, molecular engineering , polymer chemistry and physics , surface chemistry , molecular biology , cell biology , and medicine . Applications in