In electrical engineering , electrical safety testing is essential to make sure electrical products and installations are safe. To meet this goal, governments and various technical bodies have developed electrical safety standards . All countries have their own electrical safety standards that must be complied with. To meet to these standards, electrical products and installations must pass electrical safety tests.
38-456: Some types of electrical safety tests include: Electrical safety tests are described in various national and international standards. A dielectric voltage withstand test (also known as a hipot test) is done by applying a voltage higher than operating voltage to the device or installation under test. In this test, the electric insulation of a product or installation is put under a voltage stress much higher than its normal operating voltage. If
76-733: A bridge circuit . The cathode-ray oscilloscope works by amplifying the voltage and using it to deflect an electron beam from a straight path, so that the deflection of the beam is proportional to the voltage. A common voltage for flashlight batteries is 1.5 volts (DC). A common voltage for automobile batteries is 12 volts (DC). Common voltages supplied by power companies to consumers are 110 to 120 volts (AC) and 220 to 240 volts (AC). The voltage in electric power transmission lines used to distribute electricity from power stations can be several hundred times greater than consumer voltages, typically 110 to 1200 kV (AC). The voltage used in overhead lines to power railway locomotives
114-430: A generator ). On a macroscopic scale, a potential difference can be caused by electrochemical processes (e.g., cells and batteries), the pressure-induced piezoelectric effect , and the thermoelectric effect . Since it is the difference in electric potential, it is a physical scalar quantity . A voltmeter can be used to measure the voltage between two points in a system. Often a common reference potential such as
152-505: A static electric field , it corresponds to the work needed per unit of charge to move a positive test charge from the first point to the second point. In the International System of Units (SI), the derived unit for voltage is the volt (V) . The voltage between points can be caused by the build-up of electric charge (e.g., a capacitor ), and from an electromotive force (e.g., electromagnetic induction in
190-402: A system a robust and reliable approach to isolation is needed such that multiple and un-related insulation system failures would need to occur before an operator or patient is put at risk. To achieve this, two independent measures of protection are required or a single measure of physical isolation such as creepage /clearance or solid insulation deemed equivalent." In addition to the insulation of
228-429: A test to check that the connections are connected in the right sequence RCD testing: on modern electrical systems RCD's and RCBO's are regularly fitted, these devices react to electricity leaking from the circuit. Leakage may happen when a person touches live parts, which can cause electricity to passes through their body instead of the normal circuit return path. No one means of protection should be totally necessary to
266-402: A test to check the wiring is correct Earth continuity test: this test is to make sure the earthing system is properly connected Live testing Earth fault loop impedance testing: this test is to check that if a fault did occur, that the system meets requirements to cause a disconnection of the supply within the time limit specified by standards Insulation resistance testing Polarity test:
304-423: A well-defined voltage between nodes in the circuit, since the electric force is not a conservative force in those cases. However, at lower frequencies when the electric and magnetic fields are not rapidly changing, this can be neglected (see electrostatic approximation ). The electric potential can be generalized to electrodynamics, so that differences in electric potential between points are well-defined even in
342-468: Is a well-defined voltage across the inductor's terminals. This is the reason that measurements with a voltmeter across an inductor are often reasonably independent of the placement of the test leads. The volt (symbol: V ) is the derived unit for electric potential , voltage, and electromotive force . The volt is named in honour of the Italian physicist Alessandro Volta (1745โ1827), who invented
380-548: Is affected by thermodynamics. The quantity measured by a voltmeter is the negative of the difference of the electrochemical potential of electrons ( Fermi level ) divided by the electron charge and commonly referred to as the voltage difference, while the pure unadjusted electrostatic potential (not measurable with a voltmeter) is sometimes called Galvani potential . The terms "voltage" and "electric potential" are ambiguous in that, in practice, they can refer to either of these in different contexts. The term electromotive force
418-427: Is between 12 kV and 50 kV (AC) or between 0.75 kV and 3 kV (DC). Inside a conductive material, the energy of an electron is affected not only by the average electric potential but also by the specific thermal and atomic environment that it is in. When a voltmeter is connected between two different types of metal, it measures not the electrostatic potential difference, but instead something else that
SECTION 10
#1732782948139456-530: Is the intensity of the electric field. In this case, the voltage increase from point A to point B is equal to the work done per unit charge, against the electric field, to move the charge from A to B without causing any acceleration. Mathematically, this is expressed as the line integral of the electric field along that path. In electrostatics, this line integral is independent of the path taken. Under this definition, any circuit where there are time-varying magnetic fields, such as AC circuits , will not have
494-450: Is the sum of the voltage between A and B and the voltage between B and C . The various voltages in a circuit can be computed using Kirchhoff's circuit laws . When talking about alternating current (AC) there is a difference between instantaneous voltage and average voltage. Instantaneous voltages can be added for direct current (DC) and AC, but average voltages can be meaningfully added only when they apply to signals that all have
532-478: Is the voltage that can be directly measured with a voltmeter. The Galvani potential that exists in structures with junctions of dissimilar materials is also work per charge but cannot be measured with a voltmeter in the external circuit (see ยง Galvani potential vs. electrochemical potential ). Voltage is defined so that negatively charged objects are pulled towards higher voltages, while positively charged objects are pulled towards lower voltages. Therefore,
570-646: Is worn. To do this test, you need to have an insulation resistance tester, which may be a small hand held battery powered device, up to a larger luggage sized tool able to achieve higher test voltages. Variables to choose before starting an electrical resistance test is the test voltage, test duration, and test points. Acceptable values of insulation resistance vary depending on circuit purpose, industry, and country. Typically, standards will dictate acceptable values. An insulation resistance test can be used for simple go/no-go testing, or for periodic condition assessment, where routine insulation resistance tests are performed, with
608-403: The conventional current in a wire or resistor always flows from higher voltage to lower voltage. Historically, voltage has been referred to using terms like "tension" and "pressure". Even today, the term "tension" is still used, for example within the phrase " high tension " (HT) which is commonly used in thermionic valve ( vacuum tube ) based and automotive electronics. In electrostatics ,
646-480: The ground of the system is used as one of the points. In this case, voltage is often mentioned at a point without completely mentioning the other measurement point. A voltage can be associated with either a source of energy or the loss, dissipation, or storage of energy. The SI unit of work per unit charge is the joule per coulomb , where 1 volt = 1 joule (of work) per 1 coulomb of charge. The old SI definition for volt used power and current ; starting in 1990,
684-533: The quantum Hall and Josephson effect were used, and in 2019 physical constants were given defined values for the definition of all SI units. Voltage is denoted symbolically by Δ V {\displaystyle \Delta V} , simplified V , especially in English -speaking countries. Internationally, the symbol U is standardized. It is used, for instance, in the context of Ohm's or Kirchhoff's circuit laws . The electrochemical potential
722-430: The voltaic pile , possibly the first chemical battery . A simple analogy for an electric circuit is water flowing in a closed circuit of pipework , driven by a mechanical pump . This can be called a "water circuit". The potential difference between two points corresponds to the pressure difference between two points. If the pump creates a pressure difference between two points, then water flowing from one point to
760-413: The circuit are not negligible, then their effects can be modelled by adding mutual inductance elements. In the case of a physical inductor though, the ideal lumped representation is often accurate. This is because the external fields of inductors are generally negligible, especially if the inductor has a closed magnetic path . If external fields are negligible, we find that is path-independent, and there
798-516: The connection to earth can also be measured. A leakage current test detects current that does not flow back through the circuit. This test may be used as part of testing GFCI or RCD operation. Visual inspection A survey without touching anything, and looking at the electrical installation or product before starting any electrical testing. A visual inspection seeks to identify damaged insulation, disconnected wires, incorrect installation, and any other visual issues. Dead testing Continuity test:
SECTION 20
#1732782948139836-505: The device being powered the additional main points the organizations have set forward with the implementation of the MOPP standards are: Example Clearance Example showing the differences between the isolation and creepage requirements for MOOP and MOPP. Voltage Voltage , also known as (electrical) potential difference , electric pressure , or electric tension is the difference in electric potential between two points. In
874-431: The device with respect to a common reference point (or ground ). The voltage drop is the difference between the two readings. Two points in an electric circuit that are connected by an ideal conductor without resistance and not within a changing magnetic field have a voltage of zero. Any two points with the same potential may be connected by a conductor and no current will flow between them. The voltage between A and C
912-740: The device's safety, so that the failure of one should not make the device immediately dangerous. MOP practices are further divided into MOOP and MOPP. A concept introduced in the standard for medical electrical equipment IEC 60601-1 . Electrical safety standard set forward by standards organizations across the globe such as the American National Standards Institute (ANSI) , Canadian Standards Association , and European Commission in IEC60601-1. MOPP safety standards aim to set basic safety requirements for medical electrical equipment. "With hazardous voltages present in
950-446: The electric field in the region exterior to each component is conservative, and voltages between nodes in the circuit are well-defined, where as long as the path of integration does not pass through the inside of any component. The above is the same formula used in electrostatics. This integral, with the path of integration being along the test leads, is what a voltmeter will actually measure. If uncontained magnetic fields throughout
988-428: The electric field, rather than to differences in electric potential. In this case, the voltage rise along some path P {\displaystyle {\mathcal {P}}} from r A {\displaystyle \mathbf {r} _{A}} to r B {\displaystyle \mathbf {r} _{B}} is given by: However, in this case the "voltage" between two points depends on
1026-426: The hipot test is done for type testing purposes, a much larger voltage may be applied. An insulation resistance test (IR test) measures the electrical resistance of insulation by applying a voltage between two locations, and measuring the resultant current flow. Proper safety precautions must be taken when doing this test, such as exclusion zones, making sure no wires are exposed, and personal protective equipment
1064-403: The insulation resistance test as a required test for electrical installations and electrical products. This test may be referred to as "meggering', after the company Megger was one of the first companies to commercialize an insulation resistance test meter. These days, many other brands are widely available. An earth continuity test checks if a metal part is connected to earth. The resistance of
1102-407: The other will be able to do work, such as driving a turbine . Similarly, work can be done by an electric current driven by the potential difference provided by a battery . For example, the voltage provided by a sufficiently-charged automobile battery can "push" a large current through the windings of an automobile's starter motor . If the pump is not working, it produces no pressure difference, and
1140-424: The path taken. In circuit analysis and electrical engineering , lumped element models are used to represent and analyze circuits. These elements are idealized and self-contained circuit elements used to model physical components. When using a lumped element model, it is assumed that the effects of changing magnetic fields produced by the circuit are suitably contained to each element. Under these assumptions,
1178-430: The points across which the voltage is measured. When using a voltmeter to measure voltage, one electrical lead of the voltmeter must be connected to the first point, one to the second point. A common use of the term "voltage" is in describing the voltage dropped across an electrical device (such as a resistor). The voltage drop across the device can be understood as the difference between measurements at each terminal of
Electrical safety testing - Misplaced Pages Continue
1216-414: The presence of time-varying fields. However, unlike in electrostatics, the electric field can no longer be expressed only in terms of the electric potential. Furthermore, the potential is no longer uniquely determined up to a constant, and can take significantly different forms depending on the choice of gauge . In this general case, some authors use the word "voltage" to refer to the line integral of
1254-419: The results tracked over time. By tracking the insulation resistance of a circuit over time, preventative maintenance may be able to be planned before equipment failure. Insulation resistance is dependent on temperature and humidity variations, therefore the temperature and humidity should be recorded when testing and compensation applied to the measured value given. Many standards and safety agencies have specified
1292-415: The same frequency and phase. Instruments for measuring voltages include the voltmeter , the potentiometer , and the oscilloscope . Analog voltmeters , such as moving-coil instruments, work by measuring the current through a fixed resistor, which, according to Ohm's law , is proportional to the voltage across the resistor. The potentiometer works by balancing the unknown voltage against a known voltage in
1330-401: The turbine will not rotate. Likewise, if the automobile's battery is very weak or "dead" (or "flat"), then it will not turn the starter motor. The hydraulic analogy is a useful way of understanding many electrical concepts. In such a system, the work done to move water is equal to the " pressure drop" (compare p.d.) multiplied by the volume of water moved. Similarly, in an electrical circuit,
1368-548: The voltage increase from point r A {\displaystyle \mathbf {r} _{A}} to some point r B {\displaystyle \mathbf {r} _{B}} is given by the change in electrostatic potential V {\textstyle V} from r A {\displaystyle \mathbf {r} _{A}} to r B {\displaystyle \mathbf {r} _{B}} . By definition, this is: where E {\displaystyle \mathbf {E} }
1406-465: The work done to move electrons or other charge carriers is equal to "electrical pressure difference" multiplied by the quantity of electrical charges moved. In relation to "flow", the larger the "pressure difference" between two points (potential difference or water pressure difference), the greater the flow between them (electric current or water flow). (See " electric power ".) Specifying a voltage measurement requires explicit or implicit specification of
1444-617: Was first used by Volta in a letter to Giovanni Aldini in 1798, and first appeared in a published paper in 1801 in Annales de chimie et de physique . Volta meant by this a force that was not an electrostatic force, specifically, an electrochemical force. The term was taken up by Michael Faraday in connection with electromagnetic induction in the 1820s. However, a clear definition of voltage and method of measuring it had not been developed at this time. Volta distinguished electromotive force (emf) from tension (potential difference):