FR-4 (or FR4 ) is a NEMA grade designation for glass-reinforced epoxy laminate material. FR-4 is a composite material composed of woven fiberglass cloth with an epoxy resin binder that is flame resistant ( self-extinguishing ).
8-422: "FR" stands for "flame retardant", and does not denote that the material complies with the standard UL94V-0 unless testing is performed to UL 94, Vertical Flame testing in Section 8 at a compliant lab. The designation FR-4 was created by NEMA in 1968. FR-4 glass epoxy is a popular and versatile high-pressure thermoset plastic laminate grade with good strength to weight ratios. With near zero water absorption, FR-4
16-487: Is a common material for printed circuit boards (PCBs). A thin layer of copper foil is typically laminated to one or both sides of an FR-4 glass epoxy panel. These are commonly referred to as copper clad laminates. The copper thickness or copper weight can vary and so is specified separately. FR-4 is also used in the construction of relays , switches , standoffs , busbars , washers , arc shields, transformers and screw terminal strips. UL 94 UL 94,
24-413: Is along the y-axis, and the z-axis is referred to as the through-plane direction. The values shown below are an example of a certain manufacturer's material. Another manufacturer's material will usually have slightly different values. Checking the actual values, for any particular material, from the manufacturer's datasheet, can be very important, for example in high frequency applications. where: FR-4
32-480: Is most commonly used as an electrical insulator possessing considerable mechanical strength. The material is known to retain its high mechanical values and electrical insulating qualities in both dry and humid conditions. These attributes, along with good fabrication characteristics, lend utility to this grade for a wide variety of electrical and mechanical applications. Grade designations for glass epoxy laminates are: G-10 , G-11, FR-4, FR-5 and FR-6 . Of these, FR-4
40-493: Is sometimes erroneously associated with UL 94, but it (and some other flammability tests) is described by UL 1581 (Reference Standard for Electrical Wires, Cables, and Flexible Cords). From lowest (Least flame-retardant) to highest (Most flame-retardant): Tests are generally conducted on a 5 × 1 ⁄ 2 in (127 × 12.7 mm) specimen of the minimum approved thickness. For 5VA and 5VB ratings, tests are performed on both bar and plaque specimens, and
48-530: Is the grade most widely in use today. G-10, the predecessor to FR-4, lacks FR-4's self-extinguishing flammability characteristics. Hence, FR-4 has since replaced G-10 in most applications. FR-4 epoxy resin systems typically employ bromine , a halogen, to facilitate flame-resistant properties in FR-4 glass epoxy laminates. Some applications where thermal destruction of the material is a desirable trait will still use G-10 non flame resistant . Which materials fall into
56-506: The "FR-4" category is defined in the NEMA LI 1-1998 standard. Typical physical and electrical properties of FR-4 are as follows. The abbreviations LW (lengthwise, warp yarn direction) and CW (crosswise, fill yarn direction) refer to the conventional perpendicular fiber orientations in the XY plane of the board (in-plane). In terms of Cartesian coordinates , lengthwise is along the x-axis, crosswise
64-648: The Standard for Safety of Flammability of Plastic Materials for Parts in Devices and Appliances testing, is a plastics flammability standard released by Underwriters Laboratories of the United States. The standard determines the material's tendency to either extinguish or spread the flame once the specimen has been ignited. UL-94 is now harmonized with IEC 60695-11-10 and 60695-11-20 and ISO 9772 and 9773 . The VW-1 (vertical wire burn) rating