The Macagua Dam , officially known as Antonio José de Sucre , is an embankment dam with concrete gravity sections on the Caroní River in Ciudad Guayana , Bolívar State , Venezuela . It is 10 kilometres (6.2 mi) upstream from the confluence of the Caroni and Orinoco Rivers , 81 km (50 mi) downstream of the Guri Dam and 22 kilometres (14 mi) downstream of the Caruachi Dam . The dam's main purpose is hydroelectric power generation and it was later named after Antonio José de Sucre .
20-441: The Macagua Dam is a 69-metre (226 ft) tall and 3,537-metre (11,604 ft) long embankment dam with concrete gravity sections for each of the three different power stations. The dam supplies water to three power stations with a generation capacity of 3,167.5 megawatts (4,247,700 hp). Macagua I 8°18′02″N 62°39′52″W / 8.30056°N 62.66444°W / 8.30056; -62.66444 ( Macagua I )
40-505: A new turbine design. Francis turbines are primarily used for producing electricity. The power output of the electric generators generally ranges from just a few kilowatts up to 1000 MW, though mini-hydro installations may be lower. The best performance is seen when the head height is between 100–300 metres (330–980 ft). Penstock diameters are between 1 and 10 m (3.3 and 32.8 ft). The speeds of different turbine units range from 70 to 1000 rpm . A wicket gate around
60-554: A reservoir is filled by the turbine (acting as a pump) driven by the generator acting as a large electrical motor during periods of low power demand, and then reversed and used to generate power during peak demand. These pump storage reservoirs act as large energy storage sources to store "excess" electrical energy in the form of water in elevated reservoirs. This is one of a few methods that allow temporary excess electrical capacity to be stored for later utilization. Jean-Victor Poncelet Too Many Requests If you report this error to
80-436: A wide range of heads and flows. This versatility, along with their high efficiency, has made them the most widely used turbine in the world. Francis type units cover a head range from 40 to 600 m (130 to 2,000 ft), and their connected generator output power varies from just a few kilowatts up to 1000 MW. Large Francis turbines are individually designed for each site to operate with the given water flow and water head at
100-513: Is a type of water turbine . It is an inward-flow reaction turbine that combines radial and axial flow concepts. Francis turbines are the most common water turbine in use today, and can achieve over 95% efficiency. The process of arriving at the modern Francis runner design took from 1848 to approximately 1920. It became known as the Francis turbine around 1920, being named after British-American engineer James B. Francis who in 1848 created
120-404: Is a type of reaction turbine, a category of turbine in which the working fluid comes to the turbine under immense pressure and the energy is extracted by the turbine blades from the working fluid. A part of the energy is given up by the fluid because of pressure changes occurring on the blades of the turbine, quantified by the expression of degree of reaction , while the remaining part of the energy
140-476: Is equal to that at the inlet to the draft tube. Using the Euler turbine equation, E / m = e = V w1 U 1 , where e is the energy transfer to the rotor per unit mass of the fluid. From the inlet velocity triangle, and Therefore The loss of kinetic energy per unit mass at the outlet is V f2 /2 . Therefore, neglecting friction, the blade efficiency becomes i.e. Degree of reaction can be defined as
160-445: Is extracted by the volute casing of the turbine. At the exit, water acts on the spinning cup-shaped runner features, leaving at low velocity and low swirl with very little kinetic or potential energy left. The turbine's exit tube is shaped to help decelerate the water flow and recover the pressure. Usually the flow velocity (velocity perpendicular to the tangential direction) remains constant throughout, i.e. V f1 = V f2 and
180-455: Is necessary, as these are major parameters affecting power production. Draft tube : The draft tube is a conduit that connects the runner exit to the tail race where the water is discharged from the turbine. Its primary function is to reduce the velocity of discharged water to minimize the loss of kinetic energy at the outlet. This permits the turbine to be set above the tail water without appreciable drop of available head. The Francis turbine
200-406: The design of high-efficiency turbines to precisely match a site's water flow and pressure ( water head ). A Francis turbine consists of the following main parts: Spiral casing : The spiral casing around the runner of the turbine is known as the volute casing or scroll case. Throughout its length, it has numerous openings at regular intervals to allow the working fluid to impinge on the blades of
220-436: The guide and stay vanes is to convert the pressure energy of the fluid into kinetic energy. It also serves to direct the flow at design angles to the runner blades. Runner blades : Runner blades are the heart of any turbine. These are the centers where the fluid strikes and the tangential force of the impact produces torque causing the shaft of the turbine to rotate. Close attention to design of blade angles at inlet and outlet
SECTION 10
#1732791691269240-460: The highest possible efficiency, typically over 90% (to 99% ). In contrast to the Pelton turbine , the Francis turbine operates at its best completely filled with water at all times. The turbine and the outlet channel may be placed lower than the lake or sea level outside, reducing the tendency for cavitation . In addition to electrical production , they may also be used for pumped storage , where
260-607: The outside of the turbine's rotating runner controls the rate of water flow through the turbine for different power production rates. Francis turbines are usually mounted with a vertical shaft, to isolate water from the generator. This also facilitates installation and maintenance. Water wheels of different types have been used for more than 1,000 years to power mills of all types, but they were relatively inefficient. Nineteenth-century efficiency improvements of water turbines allowed them to replace nearly all water wheel applications and compete with steam engines wherever water power
280-433: The ratio of pressure energy change in the blades to total energy change of the fluid. This means that it is a ratio indicating the fraction of total change in fluid pressure energy occurring in the blades of the turbine. The rest of the changes occur in the stator blades of the turbines and the volute casing as it has a varying cross-sectional area. For example, if the degree of reaction is given as 50%, that means that half of
300-400: The runner. These openings convert the pressure energy of the fluid into kinetic energy just before the fluid impinges on the blades. This maintains a constant velocity despite the fact that numerous openings have been provided for the fluid to enter the blades, as the cross-sectional area of this casing decreases uniformly along the circumference. Guide and stay vanes : The primary function of
320-606: The same principles. S. B. Howd obtained a US patent in 1838 for a similar design. In 1848 James B. Francis , while working as head engineer of the Locks and Canals company in the water wheel-powered textile factory city of Lowell, Massachusetts , improved on these designs to create more efficient turbines. He applied scientific principles and testing methods to produce a very efficient turbine design. More importantly, his mathematical and graphical calculation methods improved turbine design and engineering. His analytical methods allowed
340-883: The total energy change of the fluid is taking place in the rotor blades and the other half is occurring in the stator blades. If the degree of reaction is zero it means that the energy changes due to the rotor blades is zero, leading to a different turbine design called the Pelton Turbine . The second equality above holds, since discharge is radial in a Francis turbine. Now, putting in the value of 'e' from above and using V 1 2 − V f 2 2 = V f 1 2 cot α 2 {\displaystyle V_{1}^{2}-V_{f2}^{2}=V_{f1}^{2}\cot \alpha _{2}} (as V f 2 = V f 1 {\displaystyle V_{f2}=V_{f1}} ) Francis turbines may be designed for
360-520: Was available. After electric generators were developed in the late 1800s, turbines were a natural source of generator power where potential hydropower sources existed. In 1826 the French engineer Benoit Fourneyron developed a high-efficiency (80%) outward-flow water turbine. Water was directed tangentially through the turbine runner, causing it to spin. Another French engineer, Jean-Victor Poncelet , designed an inward-flow turbine in about 1820 that used
380-780: Was constructed from 1956 to 1961 and it contains 6 x 64 megawatts (86,000 hp) Francis turbine -generators for an installed capacity of 384 megawatts (515,000 hp). Currently, Macagua I is undergoing a refurbishment in order to increase the capacity of each generator from 64 MW to 79.5 megawatts (106,600 hp). The first generator was complete in 2010, the second is expected to be completed in 2011 and another each year thereafter. Macagua II 8°18′14″N 62°40′04″W / 8.30389°N 62.66778°W / 8.30389; -62.66778 ( Macagua II ) contains 12 x 216 megawatts (290,000 hp) Francis turbine-generators for an installed capacity of 1,592 megawatts (2,135,000 hp). Macagua II began operation in 1996 and
400-496: Was inaugurated in January 1997. Macagua III 8°18′09″N 62°40′46″W / 8.30250°N 62.67944°W / 8.30250; -62.67944 ( Macagua III ) contains 2 x 88 megawatts (118,000 hp) Kaplan turbine -generators for an installed capacity of 176 megawatts (236,000 hp). Macagua II began operation in 1996 and was inaugurated in January 1997. Francis turbine The Francis turbine
#268731