Misplaced Pages

Murphree Area

Article snapshot taken from Wikipedia with creative commons attribution-sharealike license. Give it a read and then ask your questions in the chat. We can research this topic together.

Murphree Area is an historic residence hall complex on the northern edge of the University of Florida campus in Gainesville, Florida . The complex is adjacent to University Avenue, one of the major public roads that serve the university and define its boundaries. It was the university's first residence area and the last one to become co-ed . The Murphree Area complex is named for Albert A. Murphree , the second president of the university, who served from 1909 to 1927. It consists of the following five residence buildings, all built between 1905 and 1939:

#438561

64-594: Buckman Hall and Thomas Hall were the first two university buildings to be built, and were dedicated on September 27, 1906. Buckman Hall was named for Henry Holland Buckman , the member of the Florida Legislature who wrote the Buckman Act, which created the modern University of Florida in 1905. Thomas Hall was named for Gainesville mayor William Reuben Thomas who supported the donation of 517 acres (2.09 km) of land and $ 40,000 from Gainesville to

128-407: A laser pointer ) usually takes the form of a button and only closes the circuit when the button is depressed. A regular on‑off switch (such as on a flashlight ) has a constant on-off feature. Dual-action switches incorporate both of these features. When a strongly inductive load such as an electric motor is switched off, the current cannot drop instantaneously to zero; a spark will jump across

192-512: A library , a dining room , and a kitchen in the center sections, and an agricultural laboratory in the south section. Both buildings had hardwood floors and potbellied stoves (for which the university provided wood for students to burn). In 1906, students paid $ 2.50 in rent to live in the halls. The collections of the Florida Museum of Natural History were for a time displayed at Thomas Hall. In 1911, final plans were made for

256-460: A multiway switching system for control of lamps by more than two switches. In building wiring, light switches are installed at convenient locations to control lighting and occasionally other circuits. By use of multiple-pole switches, multiway switching control of a lamp can be obtained from two or more places, such as the ends of a corridor or stairwell. A wireless light switch allows remote control of lamps for convenience; some lamps include

320-500: A radio controlled overhead crane may have a large multi-circuit rotary switch to transfer hard-wired control signals from the local manual controls in the cab to the outputs of the remote control receiver. A toggle switch or tumbler switch is a class of electrical switches that are manually actuated by a mechanical lever , handle, or rocking mechanism. Toggle switches are available in many different styles and sizes, and are used in numerous applications. Many are designed to provide

384-417: A sail switch ensures that air flow is adequate in a duct. Pressure switches respond to fluid pressure. The mercury switch consists of a drop of mercury inside a glass bulb with two or more contacts. The two contacts pass through the glass, and are connected by the mercury when the bulb is tilted to make the mercury roll on to them. This type of switch performs much better than the ball tilt switch, as

448-582: A sensing element to sense the position of a machine part, liquid level, pressure, or temperature, such as a thermostat . Many specialized forms exist, such as the toggle switch , rotary switch , mercury switch , push-button switch, reversing switch , relay , and circuit breaker . A common use is control of lighting, where multiple switches may be wired into one circuit to allow convenient control of light fixtures. Switches in high-powered circuits must have special construction to prevent destructive arcing when they are opened. The most familiar form of switch

512-636: A 15- amp service. In 2000, a $ 2.5 million four-year electrical upgrade project began with the aim of providing at least one 20-amp circuit per student. The project required total rewiring of the halls—from transformers to each outlet and switch —and the installation of a new 23,000-volt primary distribution switch. In 2002, a $ 500,000 project to landscape the university’s historic area (the Murphree Area courtyard and University Avenue area) began when Florida alumni Herb and Catherine Yardley of Fort Lauderdale gave $ 250,000 to be matched by

576-468: A cam. It has an array of terminals, arranged in a circle around the rotor, each of which serves as a contact for the "spoke" through which any one of a number of different electrical circuits can be connected to the rotor. The switch is layered to allow the use of multiple poles, each layer is equivalent to one pole. Usually such a switch has a detent mechanism so it "clicks" from one active position to another rather than stalls in an intermediate position. Thus

640-431: A contact that can be connected to either of two other contacts, a triple-throw has a contact which can be connected to one of three other contacts, etc. In a switch where the contacts remain in one state unless actuated, such as a push-button switch, the contacts can either be normally open (abbreviated " n.o. " or " no ") until closed by operation of the switch, or normally closed (" n.c. " or " nc ") and opened by

704-414: A cost of $ 75,250 per building. Both buildings were designed for student housing but have served many uses, and in their early history were used to house the entire university. Buckman Hall contained a six-bed infirmary , gymnasium , and an apartment for a professor (the "officer-in-charge"). Thomas Hall contained administration offices in the north section, classrooms , laboratories , an auditorium ,

SECTION 10

#1732794458439

768-445: A flat metal blade, hinged at one end, with an insulating handle for operation, and a fixed contact. When the switch is closed, current flows through the hinged pivot and blade and through the fixed contact. Such switches are usually not enclosed. The knife and contacts are typically formed of copper , steel , or brass , depending on the application. Fixed contacts may be backed up with a spring. Several parallel blades can be operated at

832-562: A given switch design. In electronics, switches are classified according to the arrangement of their contacts. A pair of contacts is said to be " closed " when current can flow from one to the other. When the contacts are separated by an insulating air gap , they are said to be " open ", and no current can flow between them at normal voltages. The terms " make " for closure of contacts and " break " for opening of contacts are also widely used. The terms pole and throw are also used to describe switch contact variations. The number of " poles "

896-700: A heating process. A switch that is operated by another electrical circuit is called a relay . Large switches may be remotely operated by a motor drive mechanism. Some switches are used to isolate electric power from a system, providing a visible point of isolation that can be padlocked if necessary to prevent accidental operation of a machine during maintenance, or to prevent electric shock. An ideal switch would have no voltage drop when closed, and would have no limits on voltage or current rating. It would have zero rise time and fall time during state changes, and would change state without "bouncing" between on and off positions. Practical switches fall short of this ideal; as

960-447: A mechanism that springs it into another position when released by an operator. The momentary push-button switch is a type of biased switch. The most common type is a "push-to-make" (or normally-open or NO) switch, which makes contact when the button is pressed and breaks when the button is released. Each key of a computer keyboard, for example, is a normally-open "push-to-make" switch. A "push-to-break" (or normally-closed or NC) switch, on

1024-588: A member for the 18th district of the Florida Senate . Buckman is known for being the author of the Buckman Act, a 1905 law that reorganized higher education into three institutions, segregated by race and gender , as follows: The Buckman Act also created the Florida Board of Control , the state-wide governing body for Florida's universities and colleges, and the predecessor of today's Florida Board of Governors . The gender separation aspect of

1088-436: A pair of contacts is touching current can pass between them, while when the contacts are separated no current can flow. Switches are made in many different configurations; they may have multiple sets of contacts controlled by the same knob or actuator, and the contacts may operate simultaneously, sequentially, or alternately. A switch may be operated manually, for example, a light switch or a keyboard button, or may function as

1152-499: A residence hall, opening in 1914. In 1940, Thomas Hall was linked to Fletcher and Sledd Halls, forming a "UF" shape that can be seen from the air. From 1940 to 1949, the interiors of Buckman and Thomas Halls were renovated, and the wood structures were replaced by steel and concrete , at a cost estimated to be between $ 37,000 and $ 54,000. In 1974, Thomas Hall was added to the National Register of Historic Places , with

1216-513: A rotary switch provides greater pole and throw capabilities than simpler switches do. Other types use a cam mechanism to operate multiple independent sets of contacts. Rotary switches were used as channel selectors on television receivers until the early 1970s, as range selectors on electrical metering equipment, as band selectors on multi-band radios and other similar purposes. In industry, rotary switches are used for control of measuring instruments, switchgear , or in control circuits. For example,

1280-535: A series of non-conductive blades spanning the distance between switch contacts, and as the arc rises, its length increases as it forms ridges rising into the spaces between the blades, until the arc is too long to stay sustained and is extinguished. A puffer may be used to blow a sudden high velocity burst of gas across the switch contacts, which rapidly extends the length of the arc to extinguish it quickly. Extremely large switches often have switch contacts surrounded by something other than air to more rapidly extinguish

1344-438: A state where a quarter of the load's rated power (or worse if the load is not purely resistive) is briefly dropped in the switch. For this reason, power switches intended to interrupt a load current have spring mechanisms to make sure the transition between on and off is as short as possible regardless of the speed at which the user moves the rocker. Power switches usually come in two types. A momentary on‑off switch (such as on

SECTION 20

#1732794458439

1408-545: A sufficient amount of wetting current is a crucial step in designing systems that use delicate switches with small contact pressure as sensor inputs. Failing to do this might result in switches remaining electrically "open" due to contact oxidation. The moving part that applies the operating force to the contacts is called the actuator , and may be a toggle or dolly , a rocker , a push-button or any type of mechanical linkage (see photo). A switch normally maintains its set position once operated. A biased switch contains

1472-404: A toggle mechanism or not. Similarly, a switch where a definitive click is heard, is called a "positive on-off switch". A very common use of this type of switch is to switch lights or other electrical equipment on or off. Multiple toggle switches may be mechanically interlocked to prevent forbidden combinations. In some contexts, particularly computing , a toggle switch, or the action of toggling,

1536-400: Is a common problem with mechanical switches, relays and battery contacts , which arises as the result of electrical contact resistance (ECR) phenomena at interfaces. Switch and relay contacts are usually made of springy metals. When the contacts strike together, their momentum and elasticity act together to cause them to bounce apart one or more times before making steady contact. The result

1600-436: Is a manually operated electromechanical device with one or more sets of electrical contacts , which are connected to external circuits. Each set of contacts can be in one of two states: either "closed" meaning the contacts are touching and electricity can flow between them, or "open", meaning the contacts are separated and the switch is nonconducting. The mechanism actuating the transition between these two states (open or closed)

1664-487: Is a rapidly pulsed electric current instead of a clean transition from zero to full current. The effect is usually unimportant in power circuits, but causes problems in some analogue and logic circuits that respond fast enough to misinterpret the on‑off pulses as a data stream. In the design of micro-contacts, controlling surface structure ( surface roughness ) and minimizing the formation of passivated layers on metallic surfaces are instrumental in inhibiting chatter. In

1728-627: Is a student organization that represents residents of the area to the Inter-Residence Hall Association and the University of Florida Department of Housing and Residence Life . The organization is one of 12 area governments (abbreviated as AGs) that represent individual areas of residence halls. MAC is one of the oldest AGs, organizing sometime before 1958. MAC stems back to the first institutions organized to represent student residents, individual committees representing

1792-419: Is also very hot and is capable of eroding the metal surfaces of the switch contacts (the same true for vacuum switches). Electric current arcing causes significant degradation of the contacts and also significant electromagnetic interference (EMI), requiring the use of arc suppression methods. Where the voltage is sufficiently high, an arc can also form as the switch is closed and the contacts approach. If

1856-575: Is part of the Cross Florida Barge Canal project, also named in honor of Buckman. Switch In electrical engineering , a switch is an electrical component that can disconnect or connect the conducting path in an electrical circuit , interrupting the electric current or diverting it from one conductor to another. The most common type of switch is an electromechanical device consisting of one or more sets of movable electrical contacts connected to external circuits. When

1920-468: Is the number of electrically separate switches which are controlled by a single physical actuator. For example, a " 2-pole " switch has two separate, parallel sets of contacts that open and close in unison via the same mechanism. The number of " throws " is the number of separate wiring path choices other than "open" that the switch can adopt for each pole. A single-throw switch has one pair of contacts that can either be closed or open. A double-throw switch has

1984-513: Is understood in the different sense of a mechanical or software switch that alternates between two states each time it is activated, regardless of mechanical construction. For example, the caps lock key on a computer causes all letters to be generated in capitals after it is pressed once; pressing it again reverts to lower-case letters. Switches can be designed to respond to any type of mechanical stimulus: for example, vibration (the trembler switch), tilt, air pressure, fluid level (a float switch ),

Murphree Area - Misplaced Pages Continue

2048-423: Is usually (there are other types of actions) either an " alternate action " (flip the switch for continuous "on" or "off") or " momentary " (push for "on" and release for "off") type. A switch may be directly manipulated by a human as a control signal to a system, such as a computer keyboard button, or to control power flow in a circuit, such as a light switch . Automatically operated switches can be used to control

2112-485: The Hammond organ , multiple wires are pressed together under the piano keys of the manuals. Their bouncing and non-synchronous closing of the switches is known as Hammond Click and compositions exist that use and emphasize this feature. Some electronic organs have a switchable replica of this sound effect. The effects of contact bounce can be eliminated by: All of these methods are referred to as 'debouncing'. When

2176-436: The contact resistance , and wetting current of a mechanical switch. Sometimes the contacts are plated with noble metals , for their excellent conductivity and resistance to corrosion. They may be designed to wipe against each other to clean off any contamination. Nonmetallic conductors, such as conductive plastic, are sometimes used. To prevent the formation of insulating oxides, a minimum wetting current may be specified for

2240-420: The electronics industry such as " single-pole, single-throw " (SPST) (the simplest type, "on or off") or " single-pole, double-throw " (SPDT), connecting either of two terminals to the common terminal. In electrical power wiring (i.e., house and building wiring by electricians ), names generally involve the suffix "-way" ; however, these terms differ between British English and American English (i.e.,

2304-405: The liquid metal connection is unaffected by dirt, debris and oxidation, it wets the contacts ensuring a very low resistance bounce-free connection, and movement and vibration do not produce a poor contact. These types can be used for precision works. It can also be used where arcing is dangerous (such as in the presence of explosive vapour) as the entire unit is sealed. Knife switches consist of

2368-554: The university's housing department . Among these are a number of traditional events that are held every year. This includes the annual Halloween event, Haunted Thomas. Henry Holland Buckman Henry Holland Buckman (1858–1914) was an attorney from Duval County, Florida . He served as a Democratic member of the Florida House of Representatives . He served on the Judiciary Committee. He also served as

2432-533: The Buckman Act was later reversed by the Florida Legislature in 1947, when Florida State University and the University of Florida began to enroll both men and women. The legislature was compelled to expand the available capacity of both institutions to make room for the World War II veterans who wished to use the G.I. Bill to pursue university educations. The racial segregation aspect of the Buckman Act

2496-551: The arc. A DPDT switch has six connections, but since polarity reversal is a very common usage of DPDT switches, some variations of the DPDT switch are internally wired specifically for polarity reversal. These crossover switches only have four terminals rather than six. Two of the terminals are inputs and two are outputs. When connected to a battery or other DC source, the 4-way switch selects from either normal or reversed polarity. Such switches can also be used as intermediate switches in

2560-461: The arc. For example, the switch contacts may operate in a vacuum, immersed in mineral oil , or in sulfur hexafluoride . In AC power service, the current periodically passes through zero; this effect makes it harder to sustain an arc on opening. Manufacturers may rate switches with lower voltage or current rating when used in DC ;circuits. When a switch is designed to switch significant power,

2624-470: The campus through his shouting and cursing at his kitchen crew, the banging of pots and pans, the hissing of steam, and the loud crackling of fire and pans as lunch was prepared—the same sounds heard when the steam heating system in the Murphree Area halls is turned on every fall. Increased electrical demands of students put heavy burdens on Thomas Hall, draining power and causing circuit overloads and thrown breakers , with four to six residents sharing

Murphree Area - Misplaced Pages Continue

2688-621: The construction of four additional buildings: an agriculture building (Floyd Hall), the University Commons Building (Cafeteria), the language hall (Anderson Hall), and the College of Education building (Peabody Hall). When these facilities were completed in fall 1913 (after a delay in funding for the Language Hall and Education Building), parts of Thomas Hall were left vacant, and Thomas Hall was renovated for use as

2752-409: The current decreases to a steady-state value. A switch designed for an incandescent lamp load can withstand this inrush current. Wetting current is the minimum current needing to flow through a mechanical switch while it is operated to break through any film of oxidation that may have been deposited on the switch contacts. The film of oxidation occurs often in areas with high humidity . Providing

2816-455: The five halls of the area, organized in 1949. Fletcher Hall , in the Murphree Area, was the location of the founding of the first residence hall association at the University of Florida. This organization went on to be the origin of the current Inter-Residence Hall Association . The organization, along with resident assistants , runs event programming in the Murphree Area (typically open to all students across campus), using funding given by

2880-407: The highest voltages. The disadvantages of the knife switch are the slow opening speed and the proximity of the operator to exposed live parts. Metal-enclosed safety disconnect switches are used for isolation of circuits in industrial power distribution. Sometimes spring-loaded auxiliary blades are fitted which momentarily carry the full current during opening, then quickly part to rapidly extinguish

2944-438: The motions of machines, for example, to indicate that a garage door has reached its full open position or that a machine tool is in a position to accept another workpiece. Switches may be operated by process variables such as pressure, temperature, flow, current, voltage, and force, acting as sensors in a process and used to automatically control a system. For example, a thermostat is a temperature-operated switch used to control

3008-413: The opening contacts. Switches for inductive loads must be rated to handle these cases. The spark will cause electromagnetic interference if not suppressed; a snubber network of a resistor and capacitor in series will quell the spark. When turned on, an incandescent lamp draws a large inrush current of about ten times the steady-state current; as the filament heats up, its resistance rises and

3072-448: The other hand, breaks contact when the button is pressed and makes contact when it is released. An example of a push-to-break switch is a button used to release a door held closed by an electromagnet . The interior lamp of a household refrigerator is controlled by a switch that is held open when the door is closed. A rotary switch operates with a twisting motion of the operating handle with at least two positions. One or more positions of

3136-424: The power being switched is sufficiently large, the electron flow across opening switch contacts is sufficient to ionize the air molecules across the tiny gap between the contacts as the switch is opened, forming a gas plasma , also known as an electric arc . The plasma is of low resistance and is able to sustain power flow, even with the separation distance between the switch contacts steadily increasing. The plasma

3200-453: The register reading A press release issued when Thomas Hall was added to register told the story of the campus legend of "Old Steve," the ghost who haunts Murphree Area, the last all-male residence area (it was designated co-ed in 1972). According to the legend, "Old Steve" was the original head cook on campus who worked in the kitchen in the center of Thomas Hall, beneath the classrooms and library. The legend states that Old Steve disrupted

3264-482: The result of roughness and oxide films, they exhibit contact resistance , limits on the current and voltage they can handle, finite switching time, etc. The ideal switch is often used in circuit analysis as it greatly simplifies the system of equations to be solved, but this can lead to a less accurate solution. Theoretical treatment of the effects of non-ideal properties is required in the design of large networks of switches, as for example used in telephone exchanges. In

SECTION 50

#1732794458439

3328-581: The same time by one handle. The parts may be mounted on an insulating base with terminals for wiring, or may be directly bolted to an insulated switch board in a large assembly. Since the electrical contacts are exposed, the switch is used only where people cannot accidentally come in contact with the switch or where the voltage is so low as to not present a hazard. Knife switches are made in many sizes from miniature switches to large devices used to carry thousands of amperes. In electrical transmission and distribution, gang-operated switches are used in circuits up to

3392-636: The simplest case, a switch has two conductive pieces, often metal , called contacts , connected to an external circuit, that touch to complete (make) the circuit, and separate to open (break) the circuit. The contact material is chosen for its resistance to corrosion, because most metals form insulating oxides that would prevent the switch from working. Contact materials are also chosen on the basis of electrical conductivity , hardness (resistance to abrasive wear), mechanical strength, low cost and low toxicity. The formation of oxide layers at contact surface, as well as surface roughness and contact pressure, determine

3456-449: The simultaneous actuation of multiple sets of electrical contacts , or the control of large amounts of electric current or mains voltages. The word "toggle" is a reference to a kind of mechanism or joint consisting of two arms, which are almost in line with each other, connected with an elbow-like pivot. However, the phrase "toggle switch" is applied to a switch with a short handle and a positive snap-action, whether it actually contains

3520-437: The speed at which the switch control is operated by the user. Movement of the switch control lever applies tension to a spring until a tipping point is reached, and the contacts suddenly snap open or closed as the spring tension is released. As the power being switched increases, other methods are used to minimize or prevent arc formation. A plasma is hot and will rise due to convection air currents. The arc can be quenched with

3584-698: The state so that the Florida Legislature would build the university in Gainesville rather than in Lake City . The buildings are constructed of brick , have three and a half floors, and are late Gothic Revival - Tudorbethan in style . The buildings were designed by architect William Augustus Edwards of the firm of Edwards and Walters, then based in Columbia, South Carolina , and were built by Jacksonville -based contractor W.T. Hadlow at

3648-413: The switch action. A switch with both types of contact is called a changeover switch or double-throw switch . These may be " make-before-break " (" MBB " or shorting) which momentarily connects both circuits, or may be " break-before-make " (" BBM " or non-shorting) which interrupts one circuit before closing the other. These terms have given rise to abbreviations for the types of switch which are used in

3712-415: The switch may be momentary (biased with a spring), requiring the operator to hold the switch in the position. Other positions may have a detent to hold the position when released. A rotary switch may have multiple levels or "decks" in order to allow it to control multiple circuits. One form of rotary switch consists of a spindle or "rotor" that has a contact arm or "spoke" which projects from its surface like

3776-451: The terms two way and three way are used with different meanings). Form A Switches with larger numbers of poles or throws can be described by replacing the "S" or "D" with a number (e.g. 3PST, SP4T, etc.) or in some cases the letter "T" (for "triple") or "Q" (for "quadruple"). In the rest of this article the terms SPST , SPDT and intermediate will be used to avoid the ambiguity. Contact bounce (also called chatter )

3840-420: The transitional state of the switch as well as the ability to withstand continuous operating currents must be considered. When a switch is in the on state, its resistance is near zero and very little power is dropped in the contacts; when a switch is in the off state, its resistance is extremely high and even less power is dropped in the contacts. However, when the switch is flicked, the resistance must pass through

3904-407: The turning of a key ( key switch ), linear or rotary movement (a limit switch or microswitch ), or presence of a magnetic field (the reed switch ). Many switches are operated automatically by changes in some environmental condition or by motion of machinery. A limit switch is used, for example, in machine tools to interlock operation with the proper position of tools. In heating or cooling systems

SECTION 60

#1732794458439

3968-399: The university. Landscape architecture students at the university assisted in the design, which includes proposed sidewalks , landscaping plants and design, walls, and seating areas. Thomas Hall is co-ed by section and occupied by 170 residents. The Murphree Area is represented to UF's student government by the Murphree Area constituent seat. The Murphree Area Council (abbreviated as MAC)

4032-466: The voltage potential is sufficient to exceed the breakdown voltage of the air separating the contacts, an arc forms which is sustained until the switch closes completely and the switch surfaces make contact. In either case, the standard method for minimizing arc formation and preventing contact damage is to use a fast-moving switch mechanism, typically using a spring-operated tipping-point mechanism to assure quick motion of switch contacts, regardless of

4096-707: Was undone by the McLaurin v. Oklahoma State Regents and Brown v. Board of Education decisions of the U.S. Supreme Court . Buckman was also instrumental in establishing a state road system in Florida and developing the St. Johns River channel. Buckman Hall at the University of Florida , and the Buckman Bridge in Jacksonville, Florida are both named for Representative Buckman. The Henry H. Buckman Lock

#438561