The roentgen or röntgen ( / ˈ r ɛ n t ɡ ə n , - dʒ ə n , ˈ r ʌ n t -/ ; symbol R ) is a legacy unit of measurement for the exposure of X-rays and gamma rays , and is defined as the electric charge freed by such radiation in a specified volume of air divided by the mass of that air ( statcoulomb per kilogram). In 1928, it was adopted as the first international measurement quantity for ionizing radiation to be defined for radiation protection , as it was then the most easily replicated method of measuring air ionization by using ion chambers . It is named after the German physicist Wilhelm Röntgen , who discovered X-rays and was awarded the first Nobel Prize in Physics for the discovery.
35-1097: (Redirected from Röntgen ) Röntgen or Roentgen may refer to: Roentgen (unit) , unit of measurement for ionizing radiation, named after Wilhelm Röntgen Wilhelm Röntgen (1845–1923), German physicist, discoverer of X-rays Abraham Roentgen (1711–1793), German cabinetmaker David Roentgen (1743–1807), German cabinetmaker, son of Abraham Roentgen Gerhard Moritz Roentgen (1795–1852), Dutch and German entrepreneur and engineer Engelbert Röntgen (1829–1897), German-Dutch violinist Heinrich Röntgen (1787–1813), German explorer Julius Röntgen (1855–1932), German-Dutch composer of classical music, son of Engelbert Röntgen Kevin Roentgen , musician, singer with American rock band Orson Roentgen (album) , by Japanese singer Hyde See also [ edit ] Röntgen rays , alternative name for X-rays Roentgenium , chemical element, Atomic Number 111 (previously unununium) Astronomical Roentgen Telescope Topics referred to by
70-413: A "free air" ion chamber to measure air kerma. IAEA safety report 16 states "The quantity air kerma should be used for calibrating the reference photon radiation fields and reference instruments. Radiation protection monitoring instruments should be calibrated in terms of dose equivalent quantities. Area dosimeters or dose ratemeters should be calibrated in terms of the ambient dose equivalent, H*(10), or
105-537: A recommendation that the definition be given in every document where the roentgen is used. The roentgen has its roots in the Villard unit defined in 1908 by the American Roentgen Ray Society as "the quantity of radiation which liberates by ionisation one esu of electricity per cm of air under normal conditions of temperature and pressure." Using 1 esu ≈ 3.33564 × 10 C and
140-401: A variable relationship to the amount of energy absorbed dose per unit mass in the target material, as different materials have different absorption characteristics. As the science of radiation dosimetry developed, this was seen as a serious shortcoming. In 1940, Louis Harold Gray , who had been studying the effect of neutron damage on human tissue, together with William Valentine Mayneord and
175-580: A wide range of matter. When measuring absorbed dose in a human due to external exposure, the SI unit the gray , or the related non-SI rad are used. From these can be developed the dose equivalents to consider biological effects from differing radiation types and target materials. These are equivalent dose , and effective dose for which the SI unit sievert or the non-SI rem are used. The following table shows radiation quantities in SI and non-SI units: Kerma (physics) In radiation physics , kerma
210-431: Is an acronym for "kinetic energy released per unit mass" (alternately, "kinetic energy released in matter", "kinetic energy released in material", or "kinetic energy released in materials" ), defined as the sum of the initial kinetic energies of all the charged particles liberated by uncharged ionizing radiation (i.e., indirectly ionizing radiation such as photons and neutrons ) in a sample of matter , divided by
245-467: Is avoided, produce in 1 cc of atmospheric air at 0 °C and 76 cm of mercury pressure such a degree of conductivity that 1 esu of charge is measured at saturation current." The stated 1 cc of air would have a mass of 1.293 mg at the conditions given, so in 1937 the ICR rewrote this definition in terms of this mass of air instead of volume, temperature and pressure. The 1937 definition
280-410: Is because ionization energy is not accounted for. While kerma approximately equals absorbed dose at low energies, kerma is much higher than absorbed dose at higher energies, because some energy escapes from the absorbing volume in the form of bremsstrahlung (X-rays) or fast-moving electrons, and is not counted as absorbed dose. Photon energy is transferred to matter in a two-step process. First, energy
315-414: Is complete." The distinction of physical dose from dose caused confusion, some of which may have led Cantrill and Parker report that the roentgen had become shorthand for 83 ergs per gram (0.0083 Gy ) of tissue. They named this derivative quantity the roentgen equivalent physical (rep) to distinguish it from the ICR roentgen. The introduction of the roentgen measurement unit, which relied upon measuring
350-667: Is different from Wikidata All article disambiguation pages All disambiguation pages Roentgen (unit) However, although this was a major step forward in standardising radiation measurement, the roentgen has the disadvantage that it is only a measure of air ionisation, and not a direct measure of radiation absorption in other materials, such as different forms of human tissue . For instance, one roentgen deposits 0.00877 grays (0.877 rads ) of absorbed dose in dry air, or 0.0096 Gy (0.96 rad) in soft tissue. One roentgen of X-rays may deposit anywhere from 0.01 to 0.04 Gy (1.0 to 4.0 rad) in bone depending on
385-757: Is larger than absorbed dose because some highly energetic secondary electrons and X-rays escape the region of interest before depositing their energy. The escaping energy is counted in kerma, but not in absorbed dose. For low-energy X-rays, this is usually a negligible distinction. This can be understood when one looks at the components of kerma. There are two independent contributions to the total kerma, collision kerma k col {\displaystyle k_{\text{col}}} and radiative kerma k rad {\displaystyle k_{\text{rad}}} – thus, K = k col + k rad {\displaystyle K=k_{\text{col}}+k_{\text{rad}}} . Collision kerma results in
SECTION 10
#1732773102822420-424: Is transferred to charged particles in the medium through various photon interactions (e.g. photoelectric effect , Compton scattering , pair production , and photodisintegration ). Next, these secondary charged particles transfer their energy to the medium through atomic excitation and ionizations. For low-energy photons, kerma is numerically approximately the same as absorbed dose. For higher-energy photons, kerma
455-537: The International Commission on Radiological Protection (ICRP) soon followed with a limit of 0.2 roentgen per day in 1934. In 1950, the ICRP reduced their recommended limit to 0.3 roentgen per week for whole-body exposure. The International Commission on Radiation Units and Measurements (ICRU) took over the definition of the roentgen in 1950, defining it as "the quantity of X or γ-radiation such that
490-584: The gray , becquerel , and sievert for this purpose and required that the curie, rad, rem and roentgen be phased out by 31 December 1985. Today the roentgen is rarely used, and the International Committee for Weights and Measures (CIPM) never accepted the use of the roentgen. From 1977 to 1998, the US NIST's translations of the SI brochure stated that the CIPM temporarily accepted the use of
525-417: The mass of the sample. It is defined by the quotient K = d E tr / d m {\displaystyle K=\operatorname {d} \!E_{\text{tr}}/\operatorname {d} \!m} . The SI unit of kerma is the gray (Gy) (or joule per kilogram ), the same as the unit of absorbed dose . However, kerma can be different from absorbed dose, depending on the energies involved. This
560-619: The "Commission for the System of Units", renamed in 1964 as the "Consultative Committee for Units" (CCU), was responsible for overseeing the development of the International System of Units (SI). At the same time it was becoming increasingly obvious that the definition of the roentgen was unsound, and in 1962 it was redefined. The CCU decided to define the SI unit of absorbed radiation in terms of energy per unit mass, which in MKS units
595-574: The ICRP began to publish their recommendations in terms of rem, and the roentgen fell into disuse. The medical imaging community still has a need for ionization measurements, but they gradually converted to using C/kg as legacy equipment was replaced. The ICRU recommended redefining the roentgen to be exactly 2.58 × 10 C/kg in 1971. In 1971 the European Economic Community , in Directive 71/354/EEC , catalogued
630-598: The ICRU recommended the rad , equal to 100 erg/g, as the new unit of measure of absorbed radiation. The rad was expressed in coherent cgs units. In the late 1950s the General Conference on Weights and Measures (CGPM) invited the ICRU to join other scientific bodies to work with the International Committee for Weights and Measures (CIPM) in the development of a system of units that could be used consistently over many disciplines. This body, initially known as
665-452: The NIST. Although a convenient quantity to measure with an air ion chamber, the roentgen had the disadvantage that it was not a direct measure of either the intensity of X-rays or their absorption, but rather was a measurement of the ionising effect of X-rays in a specific circumstance; which was dry air at 0 °C and 1 standard atmosphere of pressure. Because of this the roentgen had
700-462: The SI. The US NIST clarified in 1998 that it was providing its own interpretations of the SI system, whereby it accepted the roentgen for use in the US with the SI, while recognizing that the CIPM did not. By then, the limitation to x and γ radiation had been dropped. NIST recommends defining the roentgen in every document where this unit is used. The continued use of the roentgen is strongly discouraged by
735-429: The air density of ~1.293 kg/m at 0 °C and 101 kPa, this converts to 2.58 × 10 C/kg, which is the modern value given by NIST. 1 esu / cm × 3.33564 × 10 C / esu × 1,000,000 cm / m ÷ 1.293 kg / m = 2.58 × 10 C / kg This definition
SECTION 20
#1732773102822770-421: The associated corpuscular emission per 0.001293 gram of air produces, in air, ions carrying 1 electrostatic unit of quantity of electricity of either sign." The 3 MeV cap was no longer part of the definition, but the degraded usefulness of this unit at high beam energies was mentioned in the accompanying text. In the meantime, the new concept of roentgen equivalent man (rem) had been developed. Starting in 1957,
805-400: The beam energy. As the science of radiation dosimetry developed, it was realised that the ionising effect, and hence tissue damage, was linked to the energy absorbed, not just radiation exposure. Consequently new radiometric units for radiation protection were defined which took this into account. In 1953 the International Commission on Radiation Units and Measurements (ICRU) recommended
840-537: The ionisation of air, replaced earlier less accurate practices that relied on timed exposure, film exposure, or fluorescence. This led the way to setting exposure limits, and the National Council on Radiation Protection and Measurements of the United States established the first formal dose limit in 1931 as 0.1 roentgen per day. The International X-ray and Radium Protection Committee , now known as
875-462: The modern units, absorbed dose for energy absorption and the equivalent dose ( sievert ) for stochastic effect, are overwhelmingly used, and the roentgen is rarely used. The International Committee for Weights and Measures (CIPM) has never accepted the use of the roentgen. The roentgen has been redefined over the years. It was last defined by the U.S.'s National Institute of Standards and Technology (NIST) in 1998 as 2.58 × 10 C /kg , with
910-430: The production of electrons that dissipate their energy as ionization and excitation due to the interaction between the charged particle and the atomic electrons. Radiative kerma results in the production of radiative photons due to the interaction between the charged particle and atomic nuclei (mostly via Bremsstrahlung radiation), but can also include photons produced by annihilation of positrons in flight. Frequently,
945-429: The quantity k col {\displaystyle k_{\text{col}}} is of interest, and is usually expressed as where g is the average fraction of energy transferred to electrons that is lost through bremsstrahlung. Air kerma is of importance in the practical calibration of instruments for photon measurement, where it is used for the traceable calibration of gamma instrument metrology facilities using
980-512: The rad, equal to 100 erg/g, as the unit of measure of the new radiation quantity absorbed dose . The rad was expressed in coherent cgs units . In 1975 the unit gray was named as the SI unit of absorbed dose. One gray is equal to 1 J/kg (i.e. 100 rad). Additionally, a new quantity, kerma , was defined for air ionisation as the exposure for instrument calibration, and from this the absorbed dose can be calculated using known coefficients for specific target materials. Today, for radiation protection,
1015-405: The radiobiologist John Read, published a paper in which a unit of measure, dubbed the " gram roentgen " (symbol: gr) defined as "that amount of neutron radiation which produces an increment in energy in unit volume of tissue equal to the increment of energy produced in unit volume of water by one roentgen of radiation" was proposed. This unit was found to be equivalent to 88 ergs in air. In 1953
1050-447: The roentgen (and other radiology units) with SI units since 1969. However, the only related CIPM decision shown in the appendix are with regards to the curie in 1964. The NIST brochures defined the roentgen as 2.58 × 10 C/kg, to be employed with exposures of x or γ radiation, but did not state the medium to be ionized. The CIPM's current SI brochure excludes the roentgen from the tables of non-SI units accepted for use with
1085-413: The same term [REDACTED] This disambiguation page lists articles associated with the title Roentgen . If an internal link led you here, you may wish to change the link to point directly to the intended article. Retrieved from " https://en.wikipedia.org/w/index.php?title=Roentgen&oldid=1244986216 " Category : Disambiguation pages Hidden categories: Short description
Roentgen - Misplaced Pages Continue
1120-532: The units of measure that could be used "for ... public health ... purposes". The directive included the curie , rad , rem , and roentgen as permissible units, but required that the use of the rad, rem and roentgen be reviewed before 31 December 1977. This document defined the roentgen as exactly 2.58 × 10 C/kg, as per the ICRU recommendation. Directive 80/181/EEC , published in December 1979, which replaced directive 71/354/EEC, explicitly catalogued
1155-404: Was J/kg. This was confirmed in 1975 by the 15th CGPM, and the unit was named the "gray" in honour of Louis Harold Gray, who had died in 1965. The gray was equal to 100 rad. The definition of the roentgen had had the attraction of being relatively simple to define for photons in air, but the gray is independent of the primary ionizing radiation type, and can be used for both kerma and absorbed dose in
1190-437: Was also extended to gamma rays, but later capped at 3 MeV in 1950. The USSR all-union committee of standards (GOST) had meanwhile adopted a significantly different definition of the roentgen in 1934. GOST standard 7623 defined it as "the physical dose of X-rays which produces charges each of one electrostatic unit in magnitude per cm of irradiated volume in air at 0 °C and normal atmospheric pressure when ionization
1225-542: Was used under different names ( e , R , and German unit of radiation ) for the next 20 years. In the meantime, the French Roentgen was given a different definition which amounted to 0.444 German R. In 1928, the International Congress of Radiology (ICR) defined the roentgen as "the quantity of X-radiation which, when the secondary electrons are fully utilised and the wall effect of the chamber