HUD USER is an information source containing reports and reference documents for the U.S. Department of Housing and Urban Development (HUD). HUD USER was established by the HUD's Office of Policy Development and Research (PD&R) in 1978.
26-526: HUD USER contains over 800 documents, comprising a variety of reference material for researchers and policy makers . In addition to published works, HUD User hosts data sets and a bibliographic database . Most of the material can be downloaded for free or purchased in print-form. HUD USER publishes at regular intervals, the Research Works newsletter , the Breakthrough e-newsletter ,
52-465: A statistical significance test for evidence of differences between units of the candidate CRM. For the simple balanced design above, this typically uses an F test following ANOVA . A check for trends with production order is also recommended. This approach is not taken in ISO Guide 35:2017; rather, emphasis is placed on deciding whether the between-unit standard deviation is sufficiently small for
78-461: A candidate reference material typically involves replicated measurements on multiple units or subsamples of the material. Homogeneity tests for CRMs follow planned experimental designs . Because the experiment is intended to test for (or estimate the size of) variation in value between different CRM units, the designs are chosen to allow separation of variation in results due to random measurement error and variation due to differences between units of
104-489: A certified reference material that satisfies additional NIST -specific criteria. In addition, commercial producers adhering to criteria and protocols defined by NIST may use the trademark "NIST traceable reference material" to designate certified reference materials with a well-defined traceability linkage to existing NIST standards for chemical measurements. ILAC describes the following five types of reference material: The preparation of certified reference materials
130-499: A charter to establish a network of mutual recognition agreements among accreditation bodies that would fulfil this aim. The ultimate aim of the ILAC is increased use and acceptance by industry as well as government of the results from accredited laboratories, including results from laboratories in other countries. In this way, the free-trade goal of a 'product tested once and accepted everywhere' can be realised. This article about
156-421: A naturally occurring material followed by measurement of each analyte. Due to the difficulty in production and value assignment, these are usually produced by national or transnational metrology institutes like NIST (USA), BAM (Germany), KRISS (Korea) and EC JRC ( European Commission Joint Research Centre). For natural materials, homogenization is often critical; natural materials are rarely homogeneous on
182-455: Is a significant change in measured value over time. Accelerated studies have been in use since at least the mid-1950s, at least for biological reference materials. CRMs are typically monitored at a range of temperatures and the results are used to predict the rate of change at a proposed, usually low, storage temperature. Often, the prediction uses a well known degradation model such as an Arrhenius model . The advantage over real-time studies
208-547: Is among the essential properties of a CRM (see definitions above), and stability assessment is accordingly required for certified reference materials. Stability under long term storage and also under conditions of transport are both expected to be assessed. "Assessment" is not synonymous with "testing"; some materials - for example, many minerals and metal alloys - may be so stable that experimental tests are not considered necessary. Other reference materials will usually undergo experimental tests of stability at some point prior to
234-495: Is described in general in ISO Guide 17034 and in more detail in ISO Guide 35. Preparation of biological reference standards is described in WHO Guidance. General steps required in production of a certified reference material typically include: In addition it may be important to assess the commutability of a reference material; this is especially important for biological materials. Detailed sample preparation depends on
260-462: Is limited. Reference Materials that do not meet all the criteria for certified reference materials are more widely available: the principal difference is the additional evidence of metrological traceability and statement of measurement uncertainty provided on the certificate for certified reference materials. ISO REMCO, the ISO committee responsible for guidance on reference materials within ISO, defines
286-439: Is more stable than the natural material it is prepared from. For example, stabilizing agents such as antioxidants or antimicrobial agents may be added to prevent degradation, liquids containing certified concentrations of trace metals may have pH adjusted to keep metals in solution, and clinical reference materials may be freeze-dried for long term storage if they can be reconstituted successfully. Homogeneity testing for
SECTION 10
#1732779663776312-464: Is that reference materials, like any other material, can degrade for unexpected reasons over time, or can degrade following different kinetic models ; predictions can then become unreliable. In most stability studies, real-time or accelerated, a few units of the reference material are tested at intervals. If the measurement system used for testing the materials is not perfectly stable, this can generate imprecise data or can be mistaken for instability of
338-451: Is that results are available sooner and predictions of stability over a much longer period than the stability study can be defended. For some applications, accelerated studies have been described as the only practical approach: In the absence of a reference method or a higher order standard, ... accelerated studies under stress conditions provide the only approach for assessment of stability The principal disadvantage of accelerated studies
364-466: The public housing population. In addition to the resources noted above, the HUD USER also hosts smaller, content-specific sections, including specialized clearing houses , housing , and community developments . HUD USER also hosts a case studies section highlighting development projects. Reference material Certified reference materials ( CRMs ) are 'controls' or standards used to check
390-627: The CRM. Among the simplest designs recommended for this purpose is a simple balanced nested design (see schematic). Typically 10-30 CRM units are taken from the batch at random; stratified random sampling is recommended so that the selected units are spread across the batch. An equal number of subsamples (usually two or three) is then taken from each CRM unit and measured. Subsamples are measured in random order. Other designs, such as randomized block designs , have also been used for CRM certification. Data processing for homogeneity tests usually involves
416-417: The cost of delaying results until the end of the stability study period. International Laboratory Accreditation Cooperation The International Laboratory Accreditation Cooperation or ILAC started as a conference in 1977 to develop international cooperation for facilitating trade by promoting the acceptance of accredited test and calibration results. In 1996, ILAC became a formal cooperation with
442-456: The following classes of reference material: Other bodies may define classes of reference material differently. WHO guidelines for biological reference materials provide the terms: For chemical substances some pharmacopoeias use the WHO terms The United States National Institute of Standards and Technology (NIST) uses the trade marked term Standard Reference Material (SRM) to denote
468-603: The intended end use. If statistical tests are used, however, the homogeneity experiment should be capable of detecting important heterogeneity, ISO Guide 35:2017 in turn requiring a sufficient combination of precision of the measurement procedure, number of RM units and number of replicates per unit. Statistical power calculations can assist in ensuring a sufficiently effective test . In extreme cases, such as microanalysis, materials must be checked for homogeneity on sub-micron scales; this may involve much larger numbers of observations and adjustments to statistical analysis. Stability
494-449: The material at intervals. Accelerated studies use a range of more stringent conditions, most commonly increased temperature, to test whether the material is likely to be stable over longer time scales. Real-time stability studies simply hold a set of RM units at a proposed storage temperature and test a proportion of them at regular intervals. The results are usually assessed by inspection and by linear regression to determine whether there
520-426: The material being distributed for sale. Where reference materials are certified for more than one property, stability is expected to be demonstrated for every certified property. There are two important strategies for CRM stability testing; simple real-time studies and accelerated testing. Real-time studies simply keep units of the material at their planned storage temperature for a suitable period of time and observe
546-405: The material. To overcome these difficulties, it is often possible to move RM units, at intervals, to some reference temperature where they remain stable, and then test all the accumulated units - which have undergone different exposure times - at the same time. This is referred to as an isochronous study. This strategy has the advantage of improving the precision of data used in assessing stability at
SECTION 20
#1732779663776572-606: The quality and metrological traceability of products, to validate analytical measurement methods, or for the calibration of instruments. A certified reference material is a particular form of measurement standard . Reference materials are particularly important for analytical chemistry and clinical analysis. Since most analytical instrumentation is comparative, it requires a sample of known composition (reference material) for accurate calibration. These reference materials are produced under stringent manufacturing procedures and differ from laboratory reagents in their certification and
598-400: The scale of grams so production of a solid natural matrix reference material typically involves processing to a fine powder or paste. Homogenization can have adverse effects, for example on proteins, so producers must take care not to over-process materials. Stability of a certified reference material is also important, so a range of strategies may be used to prepare a reference material that
624-429: The traceability of the data provided. Quality management systems involving laboratory accreditation under national and international accreditation/certification standards such as ISO/IEC 17025 require metrological traceability to Certified Reference Materials (where possible) when using reference materials for calibration . Whilst Certified Reference Materials are preferred where available, their availability
650-543: The tri-quarterly Cityscape journal and a quarterly report on U.S. housing market conditions. HUD USER provides researchers with access to the original data sets generated by PD&R-sponsored data collection efforts. These data sets include the American Housing Survey , HUD median family income limits, microdata from research initiatives, the HUD-insured multifamily housing stock, and
676-404: The type of material. Pure standards are most likely to be prepared by chemical synthesis and purification and characterized by determination of remaining impurities. This is often done by commercial producers. Natural matrix CRMs (often shortened to 'matrix CRMs') contain an analyte or analytes in a natural sample (for, example, lead in fish tissue). These are typically produced by homogenization of
#775224