In systems involving heat transfer , a condenser is a heat exchanger used to condense a gaseous substance into a liquid state through cooling. In doing so, the latent heat is released by the substance and transferred to the surrounding environment. Condensers are used for efficient heat rejection in many industrial systems. Condensers can be made according to numerous designs and come in many sizes ranging from rather small (hand-held) to very large (industrial-scale units used in plant processes). For example, a refrigerator uses a condenser to get rid of heat extracted from the interior of the unit to the outside air.

#505494

74-466: Condensers are used in air conditioning , industrial chemical processes such as distillation , steam power plants , and other heat-exchange systems. The use of cooling water or surrounding air as the coolant is common in many condensers. The earliest laboratory condenser, a " Gegenstromkühler " (counter-flow condenser), was invented in 1771 by the Swedish-German chemist Christian Weigel . By

148-521: A compressor to raise the pressure of the refrigerant and move it along, and a fan for blowing outside air through the heat exchanger section to cool the refrigerant inside. A typical configuration of such a condenser unit is as follows: The heat exchanger section wraps around the sides of the unit with the compressor inside. In this heat exchanger section, the refrigerant goes through multiple tube passes, which are surrounded by heat transfer fins through which cooling air can circulate from outside to inside

222-420: A crankcase , crankshaft , piston rod , piston , piston ring , cylinder head and valves. This compressor uses two interleaving scrolls to compress the refrigerant. it consists of one fixed and one orbiting scrolls. This type of compressor is more efficient because it has 70 percent less moving parts than a reciprocating compressor. This compressor use two very closely meshing spiral rotors to compress

296-457: A liquid . Examples include the Liebig condenser , Graham condenser , and Allihn condenser . This is not to be confused with a condensation reaction which links two fragments into a single molecule by an addition reaction and an elimination reaction. In laboratory distillation , reflux , and rotary evaporators , several types of condensers are commonly used. The Liebig condenser is simply

370-420: A temperature lower than its critical temperature , which means that the vapor can be condensed to a liquid by increasing the pressure on it without reducing the temperature of the vapor. A vapor is different from an aerosol . An aerosol is a suspension of tiny particles of liquid, solid, or both within a gas. For example, water has a critical temperature of 647 K (374 °C; 705 °F), which

444-501: A "wired thermostat," is a device that controls an air conditioner by switching heating or cooling on or off. It uses different sensors to measure temperatures and actuate control operations. Mechanical thermostats commonly use bimetallic strips , converting a temperature change into mechanical displacement, to actuate control of the air conditioner. Electronic thermostats, instead, use a thermistor or other semiconductor sensor, processing temperature change as electronic signals to control

518-534: A 1939 architecture graduate from the University of Texas at Austin , developed the first experimental "suburb" with inbuilt air conditioning in each house. 22 homes were developed on a flat, treeless track in northwest Austin, Texas , and the community was christened the 'Austin Air-Conditioned Village.' The residents were subjected to a year-long study of the effects of air conditioning led by

592-570: A 24-hour period. The value is equal to 12,000 BTU IT per hour, or 3,517 watts . Residential central air systems are usually from 1 to 5 tons (3.5 to 18 kW) in capacity. The efficiency of air conditioners is often rated by the seasonal energy efficiency ratio (SEER), which is defined by the Air Conditioning, Heating and Refrigeration Institute in its 2008 standard AHRI 210/240, Performance Rating of Unitary Air-Conditioning and Air-Source Heat Pump Equipment . A similar standard

666-453: A barrier such as the wall of a heat exchanger tube. The vapor gives up its latent heat and condenses to a liquid, while the liquid absorbs this heat and undergoes a temperature rise. The entering vapor and liquid typically contain a single condensable substance, such as a water spray being used to cool air and adjust its humidity. For an ideal single-pass condenser whose coolant has constant density, constant heat capacity, linear enthalpy over

740-405: A cooling tower on its condenser side. An air source heat pump shares many components with an air conditioning system, but includes a reversing valve , which allows the unit to be used to heat as well as cool a space. Air conditioning equipment will reduce the absolute humidity of the air processed by the system if the surface of the evaporator coil is significantly cooler than the dew point of

814-422: A defrosting cycle to be performed. The icing problem becomes much more severe with lower outdoor temperatures, so heat pumps are sometimes installed in tandem with a more conventional form of heating, such as an electrical heater, a natural gas , heating oil , or wood-burning fireplace or central heating , which is used instead of or in addition to the heat pump during harsher winter temperatures. In this case,

SECTION 10

#1732780277506

888-654: A family of systems and techniques that provide heating, ventilation, and air conditioning (HVAC) . Heat pumps are similar in many ways to air conditioners, but use a reversing valve to allow them both to heat and to cool an enclosed space. Air conditioners, which typically use vapor-compression refrigeration , range in size from small units used in vehicles or single rooms to massive units that can cool large buildings. Air source heat pumps , which can be used for heating as well as cooling , are becoming increasingly common in cooler climates. Air conditioners can reduce mortality rates due to higher temperature. According to

962-778: A gap between the two walls to encourage air flow, were found in the ancient city of Hamoukar , in modern Syria . Ancient Egyptian buildings also used a wide variety of passive air-conditioning techniques. These became widespread from the Iberian Peninsula through North Africa, the Middle East, and Northern India. Passive techniques remained widespread until the 20th century when they fell out of fashion and were replaced by powered air conditioning. Using information from engineering studies of traditional buildings, passive techniques are being revived and modified for 21st-century architectural designs. Air conditioners allow

1036-472: A jacket for the water. Larger condensers are also used in industrial-scale distillation processes to cool distilled vapor into liquid distillate. Commonly, the coolant flows through the tube side and distilled vapor through the shell side with distillate collecting at or flowing out the bottom. A condenser unit used in central air conditioning systems typically has a heat exchanger section to cool down and condense incoming refrigerant vapor into liquid,

1110-432: A liquid or solid is not affected by the amount of contact with the liquid or solid interface. The normal boiling point of a liquid is the temperature at which the vapor pressure is equal to normal atmospheric pressure . For two-phase systems (e.g., two liquid phases), the vapor pressure of the individual phases are equal. In the absence of stronger inter-species attractions between like-like or like-unlike molecules,

1184-456: A patent in 1851, but following the death of his main backer, he was not able to realize his invention. In 1851, James Harrison created the first mechanical ice-making machine in Geelong, Australia , and was granted a patent for an ether vapor-compression refrigeration system in 1855 that produced three tons of ice per day. In 1860, Harrison established a second ice company. He later entered

1258-425: A quantity of gas from discharge to the suction side. The compressor will keep operating at the same speed, but due to the bypass, the refrigerant mass flow circulating with the system is reduced, and thus the cooling capacity. This naturally causes the compressor to run uselessly during the periods when the bypass is operating. The turn down capacity varies between 0 and 100%. Several compressors can be installed in

1332-405: A remote control to the air conditioner. The output of the infrared LED (like that of any infrared remote) is invisible to the human eye because its wavelength is beyond the range of visible light (940 nm). This system is commonly used on mini-split air conditioners because it is simple and portable. Some window and ducted central air conditioners uses it as well. A wired controller, also called

1406-460: A single or a few rooms of a building, without ducts and in a decentralized manner. Multi-zone or multi-split systems are a common application of ductless systems and allow up to eight rooms (zones or locations) to be conditioned independently from each other, each with its indoor unit and simultaneously from a single outdoor unit. The first mini-split system was sold in 1961 by Toshiba in Japan, and

1480-438: A split central system, and deliver air, possibly through ducts, to the spaces to be cooled. Depending on their construction they may be outdoors or indoors, on roofs ( rooftop units ), draw the air to be conditioned from inside or outside a building and be water or air-cooled. Often, outdoor units are air-cooled while indoor units are liquid-cooled using a cooling tower. medium (large capacity) This compressor consists of

1554-402: A state of equilibrium . The term gas refers to a compressible fluid phase. Fixed gases are gases for which no liquid or solid can form at the temperature of the gas, such as air at typical ambient temperatures. A liquid or solid does not have to boil to release a vapor. Vapor is responsible for the familiar processes of cloud formation and condensation . It is commonly employed to carry out

SECTION 20

#1732780277506

1628-817: A straight tube within a cooling water jacket and is the simplest (and relatively least expensive) form of condenser. The Graham condenser is a spiral tube within a water jacket, and the Allihn condenser has a series of large and small constrictions on the inside tube, each increasing the surface area upon which the vapor constituents may condense. Being more complex shapes to manufacture, these latter types are also more expensive to purchase. These three types of condensers are laboratory glassware items since they are typically made of glass. Commercially available condensers usually are fitted with ground glass joints and come in standard lengths of 100, 200, and 400 mm. Air-cooled condensers are unjacketed, while water-cooled condensers contain

1702-541: A thin film of ice formed on the surface of the thermometer's bulb and that the ice mass was about 6 mm ( 1 ⁄ 4  in) thick when they stopped the experiment upon reaching −14 °C (7 °F). Franklin concluded: "From this experiment, one may see the possibility of freezing a man to death on a warm summer's day." The 19th century included many developments in compression technology. In 1820, English scientist and inventor Michael Faraday discovered that compressing and liquefying ammonia could chill air when

1776-424: A window frame or on a wall opening. The unit usually has an internal partition separating its indoor and outdoor sides, which contain the unit's condenser and evaporator, respectively. PTAC systems may be adapted to provide heating in cold weather, either directly by using an electric strip, gas , or other heaters, or by reversing the refrigerant flow to heat the interior and draw heat from the exterior air, converting

1850-407: Is highly dependent on operating conditions, especially absolute temperature and relative temperature between sink and system, and is often graphed or averaged against expected conditions. Air conditioner equipment power in the U.S. is often described in terms of " tons of refrigeration ", with each approximately equal to the cooling power of one short ton (2,000 pounds (910 kg) of ice melting in

1924-443: Is one in which condensing medium and vapors are physically separated and used when direct contact is not desired. It is a shell and tube heat exchanger installed at the outlet of every steam turbine in thermal power stations . Commonly, the cooling water flows through the tube side and the steam enters the shell side where the condensation occurs on the outside of the heat transfer tubes. The condensate drips down and collects at

1998-503: Is rejected to the environment and an internal heat exchanger (the evaporator , or Fan Coil Unit, FCU) with the piped refrigerant being circulated between the two. The FCU is then connected to the spaces to be cooled by ventilation ducts . Floor standing air conditioners are similar to this type of air conditioner but sit within spaces that need cooling. Large central cooling plants may use intermediate coolant such as chilled water pumped into air handlers or fan coil units near or in

2072-469: Is the European seasonal energy efficiency ratio (ESEER). Efficiency is strongly affected by the humidity of the air to be cooled. Dehumidifying the air before attempting to cool it can reduce subsequent cooling costs by as much as 90 percent. Thus, reducing dehumidifying costs can materially affect overall air conditioning costs. This type of controller uses an infrared LED to relay commands from

2146-431: Is the highest temperature at which liquid water can exist at any pressure. In the atmosphere at ordinary temperatures gaseous water (known as water vapor ) will condense into a liquid if its partial pressure is increased sufficiently. A vapor may co-exist with a liquid (or a solid). When this is true, the two phases will be in equilibrium, and the gas-partial pressure will be equal to the equilibrium vapor pressure of

2220-408: Is the process of removing heat from an enclosed space to achieve a more comfortable interior temperature (sometimes referred to as 'comfort cooling') and in some cases also strictly controlling the humidity of internal air. Air conditioning can be achieved using a mechanical 'air conditioner' or by other methods, including passive cooling and ventilative cooling . Air conditioning is a member of

2294-518: The International Energy Agency (IEA) 1.6 billion air conditioning units were used globally in 2016. The United Nations called for the technology to be made more sustainable to mitigate climate change and for the use of alternatives, like passive cooling, evaporative cooling , selective shading, windcatchers , and better thermal insulation . Air conditioning dates back to prehistory. Double-walled living quarters, with

Condenser (heat transfer) - Misplaced Pages Continue

2368-534: The West ). Cooling in traditional air conditioner systems is accomplished using the vapor-compression cycle, which uses a refrigerant's forced circulation and phase change between gas and liquid to transfer heat. The vapor-compression cycle can occur within a unitary, or packaged piece of equipment; or within a chiller that is connected to terminal cooling equipment (such as a fan coil unit in an air handler) on its evaporator side and heat rejection equipment such as

2442-400: The condensation of a vapor into a liquid. The vapor typically enters the condenser at a temperature above that of the secondary fluid. As the vapor cools, it reaches the saturation temperature , condenses into liquid, and releases large quantities of latent heat . As this process occurs along the condenser, the quantity of vapor decreases and the quantity of liquid increases; at the outlet of

2516-400: The refrigeration cycle and act as an air source heat pump , thus heating instead of cooling the indoor environment. They are also commonly referred to as "reverse cycle air conditioners". The heat pump is significantly more energy-efficient than electric resistance heating , because it moves energy from air or groundwater to the heated space and the heat from purchased electrical energy. When

2590-500: The Great Hall of Westminster Abbey with an apparatus of troughs and vats. Drebbel's contemporary Francis Bacon , like della Porta a believer in science communication , may not have been present at the demonstration, but in a book published later the same year, he described it as "experiment of artificial freezing" and said that "Nitre (or rather its spirit) is very cold, and hence nitre or salt when added to snow or ice intensifies

2664-410: The air conditioner into a heat pump . They may be installed in a wall opening with the help of a special sleeve on the wall and a custom grill that is flush with the wall and window air conditioners can also be installed in a window, but without a custom grill. Packaged air conditioners (also known as self-contained units) are central systems that integrate into a single housing all the components of

2738-400: The air conditioner. These controllers are usually used in hotel rooms because they are permanently installed into a wall and hard-wired directly into the air conditioner unit, eliminating the need for batteries. * where the typical capacity is in kilowatt as follows: Ductless systems (often mini-split, though there are now ducted mini-split) typically supply conditioned and heated air to

2812-441: The air in his textile mill. Cramer coined the term "air conditioning" in a patent claim which he filed that year, where he suggested that air conditioning was analogous to "water conditioning", then a well-known process for making textiles easier to process. He combined moisture with ventilation to "condition" and change the air in the factories; thus, controlling the humidity that is necessary in textile plants. Willis Carrier adopted

2886-440: The atmosphere even in liquid-cooled chillers through the use of cooling towers . Chillers may be air- or liquid-cooled. A portable system has an indoor unit on wheels connected to an outdoor unit via flexible pipes, similar to a permanently fixed installed unit (such as a ductless split air conditioner). Hose systems, which can be monoblock or air-to-air , are vented to the outside via air ducts. The monoblock type collects

2960-617: The biggest increases in India and China . Between 1995 and 2004, the proportion of urban households in China with air conditioners increased from 8% to 70%. As of 2015, nearly 100 million homes, or about 87% of US households, had air conditioning systems. In 2019, it was estimated that 90% of new single-family homes constructed in the US included air conditioning (ranging from 99% in the South to 62% in

3034-410: The bottom, often in a built-in pan called a hotwell . The shell side often operates at a vacuum or partial vacuum, produced by the difference in specific volume between the steam and condensate. Conversely, the vapor can be fed through the tubes with the coolant water or air flowing around the outside. In chemistry , a condenser is the apparatus that cools hot vapors , causing them to condense into

Condenser (heat transfer) - Misplaced Pages Continue

3108-411: The building they are trying to cool, with tubing between the unit and building, one for vapor refrigerant entering and another for liquid refrigerant leaving the unit. Of course, an electric power supply is needed for the compressor and fan inside the unit. In a direct-contact condenser , hot vapor and cool liquid are introduced into a vessel and allowed to mix directly, rather than being separated by

3182-626: The building's indoor environment to remain relatively constant, largely independent of changes in external weather conditions and internal heat loads. They also enable deep plan buildings to be created and have allowed people to live comfortably in hotter parts of the world. In 1558, Giambattista della Porta described a method of chilling ice to temperatures far below its freezing point by mixing it with potassium nitrate (then called "nitre") in his popular science book Natural Magic . In 1620, Cornelis Drebbel demonstrated "Turning Summer into Winter" for James I of England , chilling part of

3256-416: The building. Variable refrigerant flow indoor units can also be turned off individually in unused spaces. The lower start-up power of VRF's DC inverter compressors and their inherent DC power requirements also allow VRF solar-powered heat pumps to be run using DC-providing solar panels. Split-system central air conditioners consist of two heat exchangers , an outside unit (the condenser ) from which heat

3330-518: The cold of the latter, the nitre by adding to its cold, but the salt by supplying activity to the cold of the snow." In 1758, Benjamin Franklin and John Hadley , a chemistry professor at the University of Cambridge , conducted experiments applying the principle of evaporation as a means to cool an object rapidly. Franklin and Hadley confirmed that the evaporation of highly volatile liquids (such as alcohol and ether ) could be used to drive down

3404-400: The compression. There are several ways to modulate the cooling capacity in refrigeration or air conditioning and heating systems . The most common in air conditioning are: on-off cycling, hot gas bypass, use or not of liquid injection, manifold configurations of multiple compressors, mechanical modulation (also called digital), and inverter technology. Hot gas bypass involves injecting

3478-505: The condenser, only liquid remains. Some condenser designs contain an additional length to subcool this condensed liquid below the saturation temperature. Countless variations exist in condenser design, with design variables including the working fluid, the secondary fluid, the geometry, and the material. Common secondary fluids include water, air, refrigerants , or phase-change materials . Condensers have two significant design advantages over other cooling technologies: A surface condenser

3552-738: The debate over competing against the American advantage of ice-refrigerated beef sales to the United Kingdom. Electricity made the development of effective units possible. In 1901, American inventor Willis H. Carrier built what is considered the first modern electrical air conditioning unit. In 1902, he installed his first air-conditioning system, in the Sackett-Wilhelms Lithographing & Publishing Company in Brooklyn, New York . His invention controlled both

3626-565: The evaporator and the condenser into the same air path; the air first passes over the evaporator coil, where it is cooled and dehumidified before passing over the condenser coil, where it is warmed again before it is released back into the room. Free cooling can sometimes be selected when the external air is cooler than the internal air. Therefore, the compressor does not need to be used, resulting in high cooling efficiencies for these times. This may also be combined with seasonal thermal energy storage . Some air conditioning systems can reverse

3700-441: The first automobile manufacturer to offer an air conditioning unit in its cars in 1939. Innovations in the latter half of the 20th century allowed more ubiquitous air conditioner use. In 1945, Robert Sherman of Lynn, Massachusetts , invented a portable, in-window air conditioner that cooled, heated, humidified, dehumidified, and filtered the air. The first inverter air conditioners were released in 1980–1981. In 1954, Ned Cole,

3774-636: The first wall-mounted mini-split air conditioner was sold in 1968 in Japan by Mitsubishi Electric , where small home sizes motivated their development. The Mitsubishi model was the first air conditioner with a cross-flow fan . In 1969, the first mini-split air conditioner was sold in the US. Multi-zone ductless systems were invented by Daikin in 1973, and variable refrigerant flow systems (which can be thought of as larger multi-split systems) were also invented by Daikin in 1982. Both were first sold in Japan. Variable refrigerant flow systems when compared with central plant cooling from an air handler , eliminate

SECTION 50

#1732780277506

3848-400: The gas. The gas enters at the suction side and moves through the threads as the screws rotate. The meshing rotors force the gas through the compressor, and the gas exits at the end of the screws. The working area is the inter-lobe volume between the male and female rotors. It is larger at the intake end, and decreases along the length of the rotors until the exhaust port. This change in volume is

3922-408: The heat pump is in heating mode, the indoor evaporator coil switches roles and becomes the condenser coil, producing heat. The outdoor condenser unit also switches roles to serve as the evaporator and discharges cold air (colder than the ambient outdoor air). Most air source heat pumps become less efficient in outdoor temperatures lower than 4 °C or 40 °F. This is partly because ice forms on

3996-400: The heat pump is used efficiently during milder temperatures, and the system is switched to the conventional heat source when the outdoor temperature is lower. The coefficient of performance (COP) of an air conditioning system is a ratio of useful heating or cooling provided to the work required. Higher COPs equate to lower operating costs. The COP usually exceeds 1; however, the exact value

4070-465: The liquefied ammonia was allowed to evaporate. In 1842, Florida physician John Gorrie used compressor technology to create ice, which he used to cool air for his patients in his hospital in Apalachicola, Florida . He hoped to eventually use his ice-making machine to regulate the temperature of buildings. He envisioned centralized air conditioning that could cool entire cities. Gorrie was granted

4144-418: The liquid (or solid). Vapor refers to a gas phase at a temperature where the same substance can also exist in the liquid or solid state, below the critical temperature of the substance. (For example, water has a critical temperature of 374 °C (647 K), which is the highest temperature at which liquid water can exist.) If the vapor is in contact with a liquid or solid phase, the two phases will be in

4218-475: The mid-19th century, German chemist Justus von Liebig would provide his own improvements on the preceding designs of Weigel and Johann Friedrich August Göttling , with the device becoming known as the Liebig condenser . A condenser is designed to transfer heat from a working fluid (e.g. water in a steam power plant) to a secondary fluid or the surrounding air. The condenser relies on the efficient heat transfer that occurs during phase changes, in this case during

4292-403: The most common type of individual room air conditioner: one designed to sit on a window ledge. The units went on sale in 1932 at US$ 10,000 to $ 50,000 (the equivalent of $ 200,000 to $ 1,100,000 in 2023.) A year later, the first air conditioning systems for cars were offered for sale. Chrysler Motors introduced the first practical semi-portable air conditioning unit in 1935, and Packard became

4366-718: The nation’s premier air conditioning companies, builders, and social scientists. In addition, researchers from UT’s Health Service and Psychology Department studied the effects on the "artificially cooled humans." One of the more amusing discoveries was that each family reported being troubled with scorpions, the leading theory being that scorpions sought cool, shady places. Other reported changes in lifestyle were that mothers baked more, families ate heavier foods, and they were more apt to choose hot drinks. Air conditioner adoption tends to increase above around $ 10,000 annual household income in warmer areas. Global GDP growth explains around 85% of increased air condition adoption by 2050, while

4440-404: The need for large cool air ducts, air handlers, and chillers; instead cool refrigerant is transported through much smaller pipes to the indoor units in the spaces to be conditioned, thus allowing for less space above dropped ceilings and a lower structural impact, while also allowing for more individual and independent temperature control of spaces. The outdoor and indoor units can be spread across

4514-430: The outdoor unit's heat exchanger coil, which blocks air flow over the coil. To compensate for this, the heat pump system must temporarily switch back into the regular air conditioning mode to switch the outdoor evaporator coil back to the condenser coil, to heat up and defrost. Therefore, some heat pump systems will have electric resistance heating in the indoor air path that is activated only in this mode to compensate for

SECTION 60

#1732780277506

4588-420: The physical processes of distillation and headspace extraction from a liquid sample prior to gas chromatography . The constituent molecules of a vapor possess vibrational, rotational, and translational motion. These motions are considered in the kinetic theory of gases . The vapor pressure is the equilibrium pressure from a liquid or a solid at a specific temperature. The equilibrium vapor pressure of

4662-498: The remaining 15% can be explained by climate change . As of 2016 an estimated 1.6 billion air conditioning units were used worldwide, with over half of them in China and USA , and a total cooling capacity of 11,675 gigawatts. The International Energy Agency predicted in 2018 that the number of air conditioning units would grow to around 4 billion units by 2050 and that the total cooling capacity would grow to around 23,000 GW, with

4736-415: The spaces to be cooled which then duct or deliver cold air into the spaces to be conditioned, rather than ducting cold air directly to these spaces from the plant, which is not done due to the low density and heat capacity of air, which would require impractically large ducts. The chilled water is cooled by chillers in the plant, which uses a refrigeration cycle to cool water, often transferring its heat to

4810-427: The surrounding air. An air conditioner designed for an occupied space will typically achieve a 30% to 60% relative humidity in the occupied space. Most modern air-conditioning systems feature a dehumidification cycle during which the compressor runs. At the same time, the fan is slowed to reduce the evaporator temperature and condense more water. A dehumidifier uses the same refrigeration cycle but incorporates both

4884-409: The system to provide the peak cooling capacity. Each compressor can run or not in order to stage the cooling capacity of the unit. The turn down capacity is either 0/33/66 or 100% for a trio configuration and either 0/50 or 100% for a tandem. Vapor In physics, a vapor ( American English ) or vapour ( Commonwealth English ; see spelling differences ) is a substance in the gas phase at

4958-412: The temperature and humidity, which helped maintain consistent paper dimensions and ink alignment at the printing plant. Later, together with six other employees, Carrier formed The Carrier Air Conditioning Company of America , a business that in 2020 employed 53,000 people and was valued at $ 18.6 billion. In 1906, Stuart W. Cramer of Charlotte, North Carolina , was exploring ways to add moisture to

5032-437: The temperature of an object past the freezing point of water. They experimented with the bulb of a mercury-in-glass thermometer as their object. They used a bellows to speed up the evaporation . They lowered the temperature of the thermometer bulb down to −14 °C (7 °F) while the ambient temperature was 18 °C (64 °F). Franklin noted that soon after they passed the freezing point of water 0 °C (32 °F),

5106-995: The temperature range, perfect cross-sectional heat transfer, and zero longitudinal heat transfer, and whose tubing has constant perimeter, constant thickness, and constant heat conductivity, and whose condensible fluid is perfectly mixed and at a constant temperature, the coolant temperature varies along its tube according to: Θ ( x ) = T H − T ( x ) T H − T ( 0 ) = e − N T U = e − h P x m ˙ c = e − G x m ˙ c L {\displaystyle \Theta (x)={\frac {T_{H}-T(x)}{T_{H}-T(0)}}=e^{-NTU}=e^{-{\frac {hPx}{{\dot {m}}c}}}=e^{-{\frac {Gx}{{\dot {m}}cL}}}} where: Air conditioning Air conditioning , often abbreviated as A/C (US) or air con (UK),

5180-405: The temporary indoor air cooling, which would otherwise be uncomfortable in the winter. Newer models have improved cold-weather performance, with efficient heating capacity down to −14 °F (−26 °C). However, there is always a chance that the humidity that condenses on the heat exchanger of the outdoor unit could freeze, even in models that have improved cold-weather performance, requiring

5254-646: The term and incorporated it into the name of his company. Domestic air conditioning soon took off. In 1914, the first domestic air conditioning was installed in Minneapolis in the home of Charles Gilbert Gates . It is, however, possible that the considerable device (c. 2.1 m × 1.8 m × 6.1 m; 7 ft × 6 ft × 20 ft) was never used, as the house remained uninhabited (Gates had already died in October 1913.) In 1931, H.H. Schultz and J.Q. Sherman developed what would become

5328-406: The unit. This also increases the surface area. There is a motorized fan inside the condenser unit near the top, which is covered by some grating to keep any objects from accidentally falling inside on the fan. The fan is used to pull outside cooling air in through the heat exchanger section at the sides and blow it out the top through the grating. These condenser units are located on the outside of

5402-424: The vapor pressure follows Raoult's law , which states that the partial pressure of each component is the product of the vapor pressure of the pure component and its mole fraction in the mixture. The total vapor pressure is the sum of the component partial pressures. E-cigarettes produce aerosols , not vapors. Since it is in the gas phase, the amount of vapor present is quantified by the partial pressure of

5476-537: The water in a bucket or tray and stops when full. The air-to-air type re-evaporates the water, discharges it through the ducted hose, and can run continuously. Many but not all portable units draw indoor air and expel it outdoors through a single duct, negatively impacting their overall cooling efficiency. Many portable air conditioners come with heat as well as a dehumidification function. The packaged terminal air conditioner (PTAC), through-the-wall, and window air conditioners are similar. These units are installed on