82-678: The Pacific DC Intertie (also called Path 65 ) is an electric power transmission line that transmits electricity from the Pacific Northwest to the Los Angeles area using high voltage direct current (HVDC). The line capacity is 3.1 gigawatts , which is enough to serve two to three million Los Angeles households and represents almost half of the Los Angeles Department of Water and Power (LADWP) electrical system's peak capacity. The intertie originates near

164-733: A bridge circuit . The cathode-ray oscilloscope works by amplifying the voltage and using it to deflect an electron beam from a straight path, so that the deflection of the beam is proportional to the voltage. A common voltage for flashlight batteries is 1.5 volts (DC). A common voltage for automobile batteries is 12 volts (DC). Common voltages supplied by power companies to consumers are 110 to 120 volts (AC) and 220 to 240 volts (AC). The voltage in electric power transmission lines used to distribute electricity from power stations can be several hundred times greater than consumer voltages, typically 110 to 1200 kV (AC). The voltage used in overhead lines to power railway locomotives

246-639: A flashover and loss of supply. Oscillatory motion of the physical line is termed conductor gallop or flutter depending on the frequency and amplitude of oscillation. Electric power can be transmitted by underground power cables . Underground cables take up no right-of-way, have lower visibility, and are less affected by weather. However, cables must be insulated. Cable and excavation costs are much higher than overhead construction. Faults in buried transmission lines take longer to locate and repair. In some metropolitan areas, cables are enclosed by metal pipe and insulated with dielectric fluid (usually an oil) that

328-409: A generating site, such as a power plant , to an electrical substation . The interconnected lines that facilitate this movement form a transmission network . This is distinct from the local wiring between high-voltage substations and customers, which is typically referred to as electric power distribution . The combined transmission and distribution network is part of electricity delivery , known as

410-430: A generator ). On a macroscopic scale, a potential difference can be caused by electrochemical processes (e.g., cells and batteries), the pressure-induced piezoelectric effect , and the thermoelectric effect . Since it is the difference in electric potential, it is a physical scalar quantity . A voltmeter can be used to measure the voltage between two points in a system. Often a common reference potential such as

492-505: A static electric field , it corresponds to the work needed per unit of charge to move a positive test charge from the first point to the second point. In the International System of Units (SI), the derived unit for voltage is the volt (V) . The voltage between points can be caused by the build-up of electric charge (e.g., a capacitor ), and from an electromotive force (e.g., electromagnetic induction in

574-1096: A few centimetres in diameter), much of the current flow is concentrated near the surface due to the skin effect . The center of the conductor carries little current but contributes weight and cost. Thus, multiple parallel cables (called bundle conductors ) are used for higher capacity. Bundle conductors are used at high voltages to reduce energy loss caused by corona discharge . Today, transmission-level voltages are usually 110 kV and above. Lower voltages, such as 66 kV and 33 kV, are usually considered subtransmission voltages, but are occasionally used on long lines with light loads. Voltages less than 33 kV are usually used for distribution . Voltages above 765 kV are considered extra high voltage and require different designs. Overhead transmission wires depend on air for insulation, requiring that lines maintain minimum clearances. Adverse weather conditions, such as high winds and low temperatures, interrupt transmission. Wind speeds as low as 23 knots (43 km/h) can permit conductors to encroach operating clearances, resulting in

656-575: A much smaller benefit than the squared reduction provided by multiplying the voltage. Long-distance transmission is typically done with overhead lines at voltages of 115 to 1,200 kV. At higher voltages, where more than 2,000 kV exists between conductor and ground, corona discharge losses are so large that they can offset the lower resistive losses in the line conductors. Measures to reduce corona losses include larger conductor diameter, hollow cores or conductor bundles. Factors that affect resistance and thus loss include temperature, spiraling, and

738-444: A network might otherwise result in synchronization problems and cascading failures . Electricity is transmitted at high voltages to reduce the energy loss due to resistance that occurs over long distances. Power is usually transmitted through overhead power lines . Underground power transmission has a significantly higher installation cost and greater operational limitations, but lowers maintenance costs. Underground transmission

820-426: A practice that later became known as distributed generation using large numbers of small generators. Transmission of alternating current (AC) became possible after Lucien Gaulard and John Dixon Gibbs built what they called the secondary generator, an early transformer provided with 1:1 turn ratio and open magnetic circuit, in 1881. The first long distance AC line was 34 kilometres (21 miles) long, built for

902-437: A total of 42 valves in each converter. The valves had a width of 7.1 feet (2.15 m), a height of 10 feet (3.2 m) and a length of 11 feet (3.5 m) and weighed 14,000 pounds (6,400 kg). Each valve contained 1.1 litres (37 US fl oz) mercury, with a weight of 33 pounds (14.9 kg). Electric power transmission Electric power transmission is the bulk movement of electrical energy from

SECTION 10

#1732772858458

984-537: A transformer and alternating current lighting system led Westinghouse to begin installing AC systems later that year. In 1888 the first designs for an AC motor appeared. These were induction motors running on polyphase current, independently invented by Galileo Ferraris and Nikola Tesla . Westinghouse licensed Tesla's design. Practical three-phase motors were designed by Mikhail Dolivo-Dobrovolsky and Charles Eugene Lancelot Brown . Widespread use of such motors were delayed many years by development problems and

1066-423: A well-defined voltage between nodes in the circuit, since the electric force is not a conservative force in those cases. However, at lower frequencies when the electric and magnetic fields are not rapidly changing, this can be neglected (see electrostatic approximation ). The electric potential can be generalized to electrodynamics, so that differences in electric potential between points are well-defined even in

1148-591: A wide area reduced costs. The most efficient plants could be used to supply varying loads during the day. Reliability was improved and capital costs were reduced, because stand-by generating capacity could be shared over many more customers and a wider area. Remote and low-cost sources of energy, such as hydroelectric power or mine-mouth coal, could be exploited to further lower costs. The 20th century's rapid industrialization made electrical transmission lines and grids critical infrastructure . Interconnection of local generation plants and small distribution networks

1230-490: Is a network of power stations , transmission lines, and substations . Energy is usually transmitted within a grid with three-phase AC . Single-phase AC is used only for distribution to end users since it is not usable for large polyphase induction motors . In the 19th century, two-phase transmission was used but required either four wires or three wires with unequal currents. Higher order phase systems require more than three wires, but deliver little or no benefit. While

1312-468: Is a well-defined voltage across the inductor's terminals. This is the reason that measurements with a voltmeter across an inductor are often reasonably independent of the placement of the test leads. The volt (symbol: V ) is the derived unit for electric potential , voltage, and electromotive force . The volt is named in honour of the Italian physicist Alessandro Volta (1745–1827), who invented

1394-548: Is affected by thermodynamics. The quantity measured by a voltmeter is the negative of the difference of the electrochemical potential of electrons ( Fermi level ) divided by the electron charge and commonly referred to as the voltage difference, while the pure unadjusted electrostatic potential (not measurable with a voltmeter) is sometimes called Galvani potential . The terms "voltage" and "electric potential" are ambiguous in that, in practice, they can refer to either of these in different contexts. The term electromotive force

1476-406: Is also ideal for connecting two AC systems that are not synchronized with each other. HVDC lines can help stabilize a power grid against cascading blackouts since power flow through the line is controllable. The Pacific Intertie takes advantage of differing power demand patterns between the northwestern and southwestern US. During winter, the northern region operates electrical heating devices while

1558-427: Is between 12 kV and 50 kV (AC) or between 0.75 kV and 3 kV (DC). Inside a conductive material, the energy of an electron is affected not only by the average electric potential but also by the specific thermal and atomic environment that it is in. When a voltmeter is connected between two different types of metal, it measures not the electrostatic potential difference, but instead something else that

1640-668: Is either static or circulated via pumps. If an electric fault damages the pipe and leaks dielectric, liquid nitrogen is used to freeze portions of the pipe to enable draining and repair. This extends the repair period and increases costs. The temperature of the pipe and surroundings are monitored throughout the repair period. Underground lines are limited by their thermal capacity, which permits less overload or re-rating lines. Long underground AC cables have significant capacitance , which reduces their ability to provide useful power beyond 50 miles (80 kilometres). DC cables are not limited in length by their capacitance. Commercial electric power

1722-473: Is improved at higher voltage and lower current. The reduced current reduces heating losses. Joule's first law states that energy losses are proportional to the square of the current. Thus, reducing the current by a factor of two lowers the energy lost to conductor resistance by a factor of four for any given size of conductor. The optimum size of a conductor for a given voltage and current can be estimated by Kelvin's law for conductor size, which states that size

SECTION 20

#1732772858458

1804-482: Is known as the base load and is generally served by large facilities with constant operating costs, termed firm power . Such facilities are nuclear, coal or hydroelectric, while other energy sources such as concentrated solar thermal and geothermal power have the potential to provide firm power. Renewable energy sources, such as solar photovoltaics, wind, wave, and tidal, are, due to their intermittency, not considered to be firm. The remaining or peak power demand,

1886-420: Is more common in urban areas or environmentally sensitive locations. Electrical energy must typically be generated at the same rate at which it is consumed. A sophisticated control system is required to ensure that power generation closely matches demand. If demand exceeds supply, the imbalance can cause generation plant(s) and transmission equipment to automatically disconnect or shut down to prevent damage. In

1968-401: Is optimal when the annual cost of energy wasted in resistance is equal to the annual capital charges of providing the conductor. At times of lower interest rates and low commodity costs, Kelvin's law indicates that thicker wires are optimal. Otherwise, thinner conductors are indicated. Since power lines are designed for long-term use, Kelvin's law is used in conjunction with long-term estimates of

2050-540: Is owned and operated by Bonneville Power Administration, while the line in Nevada and California is owned and operated by Los Angeles Department of Water and Power. The transition is at the Oregon–Nevada border, at 41°59′47″N 119°57′44″W  /  41.9964°N 119.9623°W  / 41.9964; -119.9623  ( Pacific Intertie ownership boundary ) . This is one of two HVDC lines serving Los Angeles;

2132-406: Is partially dependent on the physical orientation of the lines with respect to each other. Three-phase lines are conventionally strung with phases separated vertically. The mutual inductance seen by a conductor of the phase in the middle of the other two phases is different from the inductance seen on the top/bottom. Unbalanced inductance among the three conductors is problematic because it may force

2214-998: Is produced at a relatively low voltage between about 2.3 kV and 30 kV, depending on the size of the unit. The voltage is then stepped up by the power station transformer to a higher voltage (115 kV to 765 kV AC) for transmission. In the United States, power transmission is, variously, 230 kV to 500 kV, with less than 230 kV or more than 500 kV as exceptions. The Western Interconnection has two primary interchange voltages: 500 kV AC at 60 Hz, and ±500 kV (1,000 kV net) DC from North to South ( Columbia River to Southern California ) and Northeast to Southwest (Utah to Southern California). The 287.5 kV ( Hoover Dam to Los Angeles line, via Victorville ) and 345 kV ( Arizona Public Service (APS) line) are local standards, both of which were implemented before 500 kV became practical. Transmitting electricity at high voltage reduces

2296-472: Is sometimes used in railway electrification systems . DC technology is used for greater efficiency over longer distances, typically hundreds of miles. High-voltage direct current (HVDC) technology is also used in submarine power cables (typically longer than 30 miles (50 km)), and in the interchange of power between grids that are not mutually synchronized. HVDC links stabilize power distribution networks where sudden new loads, or blackouts, in one part of

2378-410: Is stepped down before the current is sent to smaller substations. Subtransmission circuits are usually arranged in loops so that a single line failure does not stop service to many customers for more than a short time. Voltage Voltage , also known as (electrical) potential difference , electric pressure , or electric tension is the difference in electric potential between two points. In

2460-666: Is supplied by peaking power plants , which are typically smaller, faster-responding, and higher cost sources, such as combined cycle or combustion turbine plants typically fueled by natural gas. Long-distance transmission (hundreds of kilometers) is cheap and efficient, with costs of US$ 0.005–0.02 per kWh, compared to annual averaged large producer costs of US$ 0.01–0.025 per kWh, retail rates upwards of US$ 0.10 per kWh, and multiples of retail for instantaneous suppliers at unpredicted high demand moments. New York often buys over 1000 MW of low-cost hydropower from Canada. Local sources (even if more expensive and infrequently used) can protect

2542-411: Is swapped at specially designed transposition towers at regular intervals along the line using various transposition schemes . Subtransmission runs at relatively lower voltages. It is uneconomical to connect all distribution substations to the high main transmission voltage, because that equipment is larger and more expensive. Typically, only larger substations connect with this high voltage. Voltage

Pacific DC Intertie - Misplaced Pages Continue

2624-530: Is the intensity of the electric field. In this case, the voltage increase from point A to point B is equal to the work done per unit charge, against the electric field, to move the charge from A to B without causing any acceleration. Mathematically, this is expressed as the line integral of the electric field along that path. In electrostatics, this line integral is independent of the path taken. Under this definition, any circuit where there are time-varying magnetic fields, such as AC circuits , will not have

2706-450: Is the sum of the voltage between A and B and the voltage between B and C . The various voltages in a circuit can be computed using Kirchhoff's circuit laws . When talking about alternating current (AC) there is a difference between instantaneous voltage and average voltage. Instantaneous voltages can be added for direct current (DC) and AC, but average voltages can be meaningfully added only when they apply to signals that all have

2788-478: Is the voltage that can be directly measured with a voltmeter. The Galvani potential that exists in structures with junctions of dissimilar materials is also work per charge but cannot be measured with a voltmeter in the external circuit (see § Galvani potential vs. electrochemical potential ). Voltage is defined so that negatively charged objects are pulled towards higher voltages, while positively charged objects are pulled towards lower voltages. Therefore,

2870-465: The I 2 R {\displaystyle I^{2}R} losses are still reduced ten-fold using the higher voltage. While power loss can also be reduced by increasing the wire's conductance (by increasing its cross-sectional area), larger conductors are heavier and more expensive. And since conductance is proportional to cross-sectional area, resistive power loss is only reduced proportionally with increasing cross-sectional area, providing

2952-668: The Columbia River at the Celilo Converter Station of Bonneville Power Administration 's grid outside The Dalles, Oregon and is connected to the Sylmar Converter Station north of Los Angeles , which is owned by five utility companies and managed by LADWP . The Intertie can transmit power in either direction, but power flows mostly from north to south. The section of the line in Oregon

3034-403: The conventional current in a wire or resistor always flows from higher voltage to lower voltage. Historically, voltage has been referred to using terms like "tension" and "pressure". Even today, the term "tension" is still used, for example within the phrase " high tension " (HT) which is commonly used in thermionic valve ( vacuum tube ) based and automotive electronics. In electrostatics ,

3116-573: The electrical grid . Efficient long-distance transmission of electric power requires high voltages . This reduces the losses produced by strong currents . Transmission lines use either alternating current (AC) or direct current (DC). The voltage level is changed with transformers . The voltage is stepped up for transmission, then reduced for local distribution. A wide area synchronous grid , known as an interconnection in North America, directly connects generators delivering AC power with

3198-480: The ground of the system is used as one of the points. In this case, voltage is often mentioned at a point without completely mentioning the other measurement point. A voltage can be associated with either a source of energy or the loss, dissipation, or storage of energy. The SI unit of work per unit charge is the joule per coulomb , where 1 volt = 1 joule (of work) per 1 coulomb of charge. The old SI definition for volt used power and current ; starting in 1990,

3280-528: The international electricity exhibition in Frankfurt . A 15 kV transmission line, approximately 175 km long, connected Lauffen on the Neckar and Frankfurt. Transmission voltages increased throughout the 20th century. By 1914, fifty-five transmission systems operating at more than 70 kV were in service. The highest voltage then used was 150 kV. Interconnecting multiple generating plants over

3362-533: The quantum Hall and Josephson effect were used, and in 2019 physical constants were given defined values for the definition of all SI units. Voltage is denoted symbolically by Δ V {\displaystyle \Delta V} , simplified V , especially in English -speaking countries. Internationally, the symbol U is standardized. It is used, for instance, in the context of Ohm's or Kirchhoff's circuit laws . The electrochemical potential

Pacific DC Intertie - Misplaced Pages Continue

3444-712: The resistance define the impedance ) constitute reactive power flow, which transmits no power to the load. These reactive currents, however, cause extra heating losses. The ratio of real power transmitted to the load to apparent power (the product of a circuit's voltage and current, without reference to phase angle) is the power factor . As reactive current increases, reactive power increases and power factor decreases. For transmission systems with low power factor, losses are higher than for systems with high power factor. Utilities add capacitor banks, reactors and other components (such as phase-shifters ; static VAR compensators ; and flexible AC transmission systems , FACTS) throughout

3526-399: The resistive losses . For example, raising the voltage by a factor of 10 reduces the current by a corresponding factor of 10 and therefore the I 2 R {\displaystyle I^{2}R} losses by a factor of 100, provided the same sized conductors are used in both cases. Even if the conductor size (cross-sectional area) is decreased ten-fold to match the lower current,

3608-506: The skin effect . Resistance increases with temperature. Spiraling, which refers to the way stranded conductors spiral about the center, also contributes to increases in conductor resistance. The skin effect causes the effective resistance to increase at higher AC frequencies. Corona and resistive losses can be estimated using a mathematical model. US transmission and distribution losses were estimated at 6.6% in 1997, 6.5% in 2007 and 5% from 2013 to 2019. In general, losses are estimated from

3690-430: The voltaic pile , possibly the first chemical battery . A simple analogy for an electric circuit is water flowing in a closed circuit of pipework , driven by a mechanical pump . This can be called a "water circuit". The potential difference between two points corresponds to the pressure difference between two points. If the pump creates a pressure difference between two points, then water flowing from one point to

3772-528: The 1884 International Exhibition of Electricity in Turin, Italy . It was powered by a 2 kV, 130 Hz Siemens & Halske alternator and featured several Gaulard transformers with primary windings connected in series, which fed incandescent lamps. The system proved the feasibility of AC electric power transmission over long distances. The first commercial AC distribution system entered service in 1885 in via dei Cerchi, Rome, Italy , for public lighting. It

3854-466: The AC grid. These stopgaps were slowly replaced as older systems were retired or upgraded. The first transmission of single-phase alternating current using high voltage came in Oregon in 1890 when power was delivered from a hydroelectric plant at Willamette Falls to the city of Portland 14 miles (23 km) down river. The first three-phase alternating current using high voltage took place in 1891 during

3936-401: The ability to link all the loads. These included single phase AC systems, poly-phase AC systems, low voltage incandescent lighting, high-voltage arc lighting, and existing DC motors in factories and street cars. In what became a universal system, these technological differences were temporarily bridged via the rotary converters and motor-generators that allowed the legacy systems to connect to

4018-413: The circuit are not negligible, then their effects can be modelled by adding mutual inductance elements. In the case of a physical inductor though, the ideal lumped representation is often accurate. This is because the external fields of inductors are generally negligible, especially if the inductor has a closed magnetic path . If external fields are negligible, we find that is path-independent, and there

4100-431: The device with respect to a common reference point (or ground ). The voltage drop is the difference between the two readings. Two points in an electric circuit that are connected by an ideal conductor without resistance and not within a changing magnetic field have a voltage of zero. Any two points with the same potential may be connected by a conductor and no current will flow between them. The voltage between A and C

4182-551: The discrepancy between power produced (as reported by power plants) and power sold; the difference constitutes transmission and distribution losses, assuming no utility theft occurs. As of 1980, the longest cost-effective distance for DC transmission was 7,000 kilometres (4,300 miles). For AC it was 4,000 kilometres (2,500 miles), though US transmission lines are substantially shorter. In any AC line, conductor inductance and capacitance can be significant. Currents that flow solely in reaction to these properties, (which together with

SECTION 50

#1732772858458

4264-446: The electric field in the region exterior to each component is conservative, and voltages between nodes in the circuit are well-defined, where as long as the path of integration does not pass through the inside of any component. The above is the same formula used in electrostatics. This integral, with the path of integration being along the test leads, is what a voltmeter will actually measure. If uncontained magnetic fields throughout

4346-428: The electric field, rather than to differences in electric potential. In this case, the voltage rise along some path P {\displaystyle {\mathcal {P}}} from r A {\displaystyle \mathbf {r} _{A}} to r B {\displaystyle \mathbf {r} _{B}} is given by: However, in this case the "voltage" between two points depends on

4428-413: The entire conductor as opposed to AC current which only penetrates to the skin depth . For the same conductor size, the effective resistance is greater with AC than DC, hence more power is lost as heat with AC. In general, the total cost for HVDC is less than an AC line if the line length is over 500–600 miles, and with advances in conversion technology, this distance has been reduced considerably. A DC line

4510-582: The first practical series AC transformer in 1885. Working with the support of George Westinghouse , in 1886 he demonstrated a transformer-based AC lighting system in Great Barrington, Massachusetts . It was powered by a steam engine-driven 500 V Siemens generator. Voltage was stepped down to 100 volts using the Stanley transformer to power incandescent lamps at 23 businesses over 4,000 feet (1,200 m). This practical demonstration of

4592-409: The fraction of energy lost to Joule heating , which varies by conductor type, the current, and the transmission distance. For example, a 100 miles (160 km) span at 765 kV carrying 1000 MW of power can have losses of 0.5% to 1.1%. A 345 kV line carrying the same load across the same distance has losses of 4.2%. For a given amount of power, a higher voltage reduces the current and thus

4674-400: The maximum reliable capacity of each line (ordinarily less than its physical or thermal limit) to ensure that spare capacity is available in the event of a failure in another part of the network. High-voltage overhead conductors are not covered by insulation. The conductor material is nearly always an aluminum alloy, formed of several strands and possibly reinforced with steel strands. Copper

4756-451: The middle line to carry a disproportionate amount of the total power transmitted. Similarly, an unbalanced load may occur if one line is consistently closest to the ground and operates at a lower impedance. Because of this phenomenon, conductors must be periodically transposed along the line so that each phase sees equal time in each relative position to balance out the mutual inductance seen by all three phases. To accomplish this, line position

4838-519: The other is Path 27 . The idea of sending hydroelectric power to Southern California had been proposed as early as the 1930s, but was opposed and scrapped. By 1961, US president John F. Kennedy authorized a large public works project, using new high voltage direct current technology from Sweden . The project was undertaken as a close collaboration between General Electric of the US and ASEA of Sweden. Private California power companies had opposed

4920-407: The other will be able to do work, such as driving a turbine . Similarly, work can be done by an electric current driven by the potential difference provided by a battery . For example, the voltage provided by a sufficiently-charged automobile battery can "push" a large current through the windings of an automobile's starter motor . If the pump is not working, it produces no pressure difference, and

5002-424: The path taken. In circuit analysis and electrical engineering , lumped element models are used to represent and analyze circuits. These elements are idealized and self-contained circuit elements used to model physical components. When using a lumped element model, it is assumed that the effects of changing magnetic fields produced by the circuit are suitably contained to each element. Under these assumptions,

SECTION 60

#1732772858458

5084-430: The points across which the voltage is measured. When using a voltmeter to measure voltage, one electrical lead of the voltmeter must be connected to the first point, one to the second point. A common use of the term "voltage" is in describing the voltage dropped across an electrical device (such as a resistor). The voltage drop across the device can be understood as the difference between measurements at each terminal of

5166-528: The power supply from weather and other disasters that can disconnect distant suppliers. Hydro and wind sources cannot be moved closer to big cities, and solar costs are lowest in remote areas where local power needs are nominal. Connection costs can determine whether any particular renewable alternative is economically realistic. Costs can be prohibitive for transmission lines, but high capacity, long distance super grid transmission network costs could be recovered with modest usage fees. At power stations , power

5248-414: The presence of time-varying fields. However, unlike in electrostatics, the electric field can no longer be expressed only in terms of the electric potential. Furthermore, the potential is no longer uniquely determined up to a constant, and can take significantly different forms depending on the choice of gauge . In this general case, some authors use the word "voltage" to refer to the line integral of

5330-467: The price of copper and aluminum as well as interest rates. Higher voltage is achieved in AC circuits by using a step-up transformer . High-voltage direct current (HVDC) systems require relatively costly conversion equipment that may be economically justified for particular projects such as submarine cables and longer distance high capacity point-to-point transmission. HVDC is necessary for sending energy between unsynchronized grids. A transmission grid

5412-514: The price of generating capacity is high, energy demand is variable, making it often cheaper to import needed power than to generate it locally. Because loads often rise and fall together across large areas, power often comes from distant sources. Because of the economic benefits of load sharing, wide area transmission grids may span countries and even continents. Interconnections between producers and consumers enables power to flow even if some links are inoperative. The slowly varying portion of demand

5494-587: The project but their technical objections were rebutted by Uno Lamm of ASEA at an IEEE meeting in New York in 1963. When completed in 1970 the combined AC and DC transmission system was estimated to save consumers in Los Angeles approximately US$ 600,000 per day by use of cheaper electric power from dams on the Columbia River . One advantage of direct current over AC is that DC current penetrates

5576-415: The same frequency and phase. Instruments for measuring voltages include the voltmeter , the potentiometer , and the oscilloscope . Analog voltmeters , such as moving-coil instruments, work by measuring the current through a fixed resistor, which, according to Ohm's law , is proportional to the voltage across the resistor. The potentiometer works by balancing the unknown voltage against a known voltage in

5658-559: The same relative frequency to many consumers. North America has four major interconnections: Western , Eastern , Quebec and Texas . One grid connects most of continental Europe . Historically, transmission and distribution lines were often owned by the same company, but starting in the 1990s, many countries liberalized the regulation of the electricity market in ways that led to separate companies handling transmission and distribution. Most North American transmission lines are high-voltage three-phase AC, although single phase AC

5740-580: The scarcity of polyphase power systems needed to power them. In the late 1880s and early 1890s smaller electric companies merged into larger corporations such as Ganz and AEG in Europe and General Electric and Westinghouse Electric in the US. These companies developed AC systems, but the technical difference between direct and alternating current systems required a much longer technical merger. Alternating current's economies of scale with large generating plants and long-distance transmission slowly added

5822-517: The scheme, completed in May 1970, used only mercury-arc valves in the converters . The valves were series connected in three six-pulse valve bridges for each pole. The blocking voltage of the valves was 133 kV with a maximum current of 1,800 amperes , for a transmission rating of 1,440 MW with a symmetrical voltage of 400 kV with respect to earth. Each converter station housed six mercury arc valves groups, consisting each of seven valves, for

5904-517: The southern portion uses relatively little electricity. In summer, the north uses little electricity while the south reaches peak demand due to air conditioning usage. Any time the Intertie demand lessens, the excess is distributed elsewhere on the western power grid (states west of the Great Plains, including Colorado and New Mexico ). The Pacific Intertie consists of: The first phase of

5986-409: The system help to compensate for the reactive power flow, reduce the losses in power transmission and stabilize system voltages. These measures are collectively called 'reactive support'. Current flowing through transmission lines induces a magnetic field that surrounds the lines of each phase and affects the inductance of the surrounding conductors of other phases. The conductors' mutual inductance

6068-401: The turbine will not rotate. Likewise, if the automobile's battery is very weak or "dead" (or "flat"), then it will not turn the starter motor. The hydraulic analogy is a useful way of understanding many electrical concepts. In such a system, the work done to move water is equal to the " pressure drop" (compare p.d.) multiplied by the volume of water moved. Similarly, in an electrical circuit,

6150-548: The voltage increase from point r A {\displaystyle \mathbf {r} _{A}} to some point r B {\displaystyle \mathbf {r} _{B}} is given by the change in electrostatic potential V {\textstyle V} from r A {\displaystyle \mathbf {r} _{A}} to r B {\displaystyle \mathbf {r} _{B}} . By definition, this is: where E {\displaystyle \mathbf {E} }

6232-465: The work done to move electrons or other charge carriers is equal to "electrical pressure difference" multiplied by the quantity of electrical charges moved. In relation to "flow", the larger the "pressure difference" between two points (potential difference or water pressure difference), the greater the flow between them (electric current or water flow). (See " electric power ".) Specifying a voltage measurement requires explicit or implicit specification of

6314-500: The worst case, this may lead to a cascading series of shutdowns and a major regional blackout . The US Northeast faced blackouts in 1965 , 1977 , 2003 , and major blackouts in other US regions in 1996 and 2011 . Electric transmission networks are interconnected into regional, national, and even continent-wide networks to reduce the risk of such a failure by providing multiple redundant , alternative routes for power to flow should such shutdowns occur. Transmission companies determine

6396-617: Was first used by Volta in a letter to Giovanni Aldini in 1798, and first appeared in a published paper in 1801 in Annales de chimie et de physique . Volta meant by this a force that was not an electrostatic force, specifically, an electrochemical force. The term was taken up by Michael Faraday in connection with electromagnetic induction in the 1820s. However, a clear definition of voltage and method of measuring it had not been developed at this time. Volta distinguished electromotive force (emf) from tension (potential difference):

6478-452: Was initially transmitted at the same voltage used by lighting and mechanical loads. This restricted the distance between generating plant and loads. In 1882, DC voltage could not easily be increased for long-distance transmission. Different classes of loads (for example, lighting, fixed motors, and traction/railway systems) required different voltages, and so used different generators and circuits. Thus, generators were sited near their loads,

6560-648: Was powered by two Siemens & Halske alternators rated 30 hp (22 kW), 2 kV at 120 Hz and used 19 km of cables and 200 parallel-connected 2 kV to 20 V step-down transformers provided with a closed magnetic circuit, one for each lamp. A few months later it was followed by the first British AC system, serving Grosvenor Gallery . It also featured Siemens alternators and 2.4 kV to 100 V step-down transformers – one per user – with shunt-connected primaries. Working to improve what he considered an impractical Gaulard-Gibbs design, electrical engineer William Stanley, Jr. developed

6642-464: Was sometimes used for overhead transmission, but aluminum is lighter, reduces yields only marginally and costs much less. Overhead conductors are supplied by several companies. Conductor material and shapes are regularly improved to increase capacity. Conductor sizes range from 12 mm (#6 American wire gauge ) to 750 mm (1,590,000  circular mils area), with varying resistance and current-carrying capacity . For large conductors (more than

6724-426: Was spurred by World War I , when large electrical generating plants were built by governments to power munitions factories. These networks use components such as power lines, cables, circuit breakers , switches and transformers . The transmission network is usually administered on a regional basis by an entity such as a regional transmission organization or transmission system operator . Transmission efficiency