Misplaced Pages

Weatherhead

Article snapshot taken from Wikipedia with creative commons attribution-sharealike license. Give it a read and then ask your questions in the chat. We can research this topic together.

A weatherhead , also called a weathercap , service head , service entrance cap , or gooseneck (slang) is a weatherproof service drop entry point where overhead power or telephone wires enter a building, or where wires transition between overhead and underground cables. At a building the wires enter a conduit , a protective metal pipe, and the weatherhead is a waterproof cap on the end of the conduit that allows the wires to enter without letting in water. It is shaped like a hood , with the surface where the wires enter facing down at an angle of at least 45°, to shield it from precipitation. A rubberized gasket makes for a tight seal against the wires . Before they enter the weatherhead, a drip loop is left in the overhead wires , which permits rain water that collects on the wires to drip off before reaching the weatherhead.

#53946

7-451: A weatherhead termination is only used at low voltages (up to 600 volts), since higher distribution voltages require more insulation between conductors and metal enclosures. Higher-voltage connections are made through a pothead . Weatherheads are required by electrical codes or building codes . They are also used on utility poles where overhead power lines enter a conduit to pass underground. This article about electric power

14-408: A weatherhead is used. The device consists of a molded plastic housing that attaches to the end of an electrical conduit that carries the underground cables up the utility pole to the crossarm . Multiple bushing insulators project from the plastic body, each ending at an electrical terminal. Each overhead wire is connected to a bushing terminal from which the current passes through a rod down

21-402: Is IEEE Std 48–2020. What was once called a pothead is now called a "Class I High-Voltage Cable Termination," which must meet these requirements: Formerly, medium- and high-voltage cables (from about 2.5 kV and above) were terminated with hand-made "stress cones" composed of multiple layers of insulating tape, semi-conductive tape, and insulating putty. By tapering the layers of tape carefully,

28-697: Is a stub . You can help Misplaced Pages by expanding it . Pothead A pothead is a type of insulated electrical terminal used for transitioning between overhead line and underground high-voltage cable or for connecting overhead wiring to equipment like transformers . Its name comes from the process of potting or encapsulation of the conductors inside the terminal's insulating bushing . Potheads are used where higher-voltage power lines go underground, generally voltages of 600 volts or greater. They are used mostly for service drops for commercial and industrial buildings. For lower voltages such as those used for residential service drops, another weather seal called

35-400: The center of the bushing to the interior of the housing, where it is connected to a wire from the conduit. Thus the device allows the overhead conductors to pass into the conduit while serving as a seal to keep out water. The purpose of the bushings, which have corrugations moulded into their surfaces, is to provide enough creepage distance along their surface to prevent leakage current from

42-468: The high voltage terminal from flowing to the grounded metal conduit. Pothead was once defined in Institute of Electrical and Electronics Engineers (IEEE) Std 48-1962 "Standards for Potheads." This standard was superseded by IEEE Std 48-1975 "IEEE Standard Test Procedures and Requirements for High-Voltage Alternating-Current Cable Terminations," and "pothead" was dropped from usage. The current standard

49-408: The potential gradient from the inside of the cable to free air was reduced so as not to cause electrical breakdown and tracking along the surface of the termination. Current practice for these terminations is to use a pre-molded rubber stress cone, which can be slipped over the cable end and shrunk to fit snugly around the exposed cable insulation. This saves considerable installation labor and reduces

#53946