Misplaced Pages

Fex

Article snapshot taken from Wikipedia with creative commons attribution-sharealike license. Give it a read and then ask your questions in the chat. We can research this topic together.

The Cisco Nexus series switches are modular and fixed port network switches designed for the data center. Cisco Systems introduced the Nexus Series of switches on January 28, 2008. The first chassis in the Nexus 7000 family is a 10-slot chassis with two supervisor engine slots and eight I/O module slots at the front, as well as five crossbar switch fabric modules at the rear. Beside the Nexus 7000 there are also other models in the Nexus range.

#887112

37-607: (Redirected from FEX ) Fex or FEX may refer to: Fabric extenders, in Cisco Nexus switches#Nexus 2000 series Fex (band) , German new wave and post-punk band Fexofenadine , an antihistamine pharmaceutical drug Foreign Extemporaneous Speaking , speech delivery style Val Fex , a valley in the Upper Engadine in Switzerland Topics referred to by

74-412: A Network Analysis Module to be run. The Nexus 2000 series are fabric extenders (FEX): 'top of rack' 1 U high system that can be used in combination with higher end Nexus switches like the 5000 , 6000 or 7000 series: the 2000 series is not a 'stand-alone' switch but needs to be connected to a parent and should be seen as a 'module' or 'remote line card' but then installed in a 19" rack instead of in

111-402: A device conforms to a smaller than 9.5-inch width so that these "half rack width" appliances may be used in a chassis system that fits the traditional 19-inch rack space, but allows for these 8.4-inch-wide "half rack width" appliances to be inserted and removed easily without tools or the need to remove adjacent hardware. This "half rack width" concept is popular in applications where IT equipment

148-556: A disagreement between Dell and Cisco, Cisco stopped development of the FEX for the M1000e in 2010 The Nexus B22FEX offer 16 x 10 Gbase-KR internal 10 Gbit/s link to each blade-server interface and up to 8 SFP+ ports for uplink with a Nexus 5010, 5548 or 5596 switch. The maximum distance between the FEX and the mother-switch is 3 kilometer when it is only used for TCP/IP traffic and 300 meter when carrying also FCoE traffic. The model 3064

185-406: A main switch-enclosure. The interconnection between this 'remote line card' and the 5000 or 7000 parent switch uses either proprietary interfaces (CX-1 for copper or the short or long range Cisco Fabric Extender Transceiver (FET) interfaces), or standard interfaces (Cisco SFP+ SR and LR fibre interface modules or SFP+ Twinax cables). In combination with the 5000/6000/7000 mother-switch you can create

222-404: A modified Nexus operating system (Nexus OS ACI). The Nexus 9000 has many models: Rack unit A rack unit (abbreviated U or RU ) is a unit of measure defined as 1 + 3 ⁄ 4 inches (44.45 mm). It is most frequently used as a measurement of the overall height of 19-inch and 23-inch rack frames , as well as the height of equipment that mounts in these frames, whereby

259-450: A rack unit is defined as 1 + 3 ⁄ 4 inches (44.45 mm), a front panel or filler panel in a rack is not an exact multiple of this height. To allow space between adjacent rack-mounted components, a panel is 1 ⁄ 32 inches (0.03125 in or 0.794 mm) less in height than the full number of rack units would imply. Thus, a 1U front panel would be 1 23 ⁄ 32 inches (1.71875 in or 43.66 mm) tall. If n

296-450: A so-called Distributed Modular System. The 2000 series consists of 4 different models. Three models offer 24 or 48 Gbit/s only or Gigabit or Fast Ethernet copper interfaces and up to four 10 Gigabit uplink interfaces on copper or fibre. The Nexus 2232PP offers thirty-two 1/10 Gbit/s Ethernet and Fibre Channel over Ethernet (FCoE) interfaces. The Nexus 2248PQ offers forty-eight 1/10 Gbit/s Ethernet and FCoE interfaces. For

333-449: A telephone company central office . A typical full-size rack is 42U, which means it holds just over 6 feet (180 cm) of equipment, and a typical "half-height" rack is 18–22U, which is around 3 feet (91 cm) high. The mounting-hole distance (as shown to the right) differs for 19-inch racks and 23-inch racks: 19-inch racks use uneven spacings (as shown to the right) while 23-inch racks use evenly spaced mounting holes. Although it

370-490: Is 1U high and half the depth of a 4-post rack (such as a network switch , router , KVM switch , or server ), such that two units can be mounted in 1U of space (one mounted at the front of the rack and one at the rear). When used to describe the rack enclosure itself, the term "half-rack" typically means a rack enclosure that is half the height (22U tall). There is also a "half rack width" size being used in IT applications where

407-490: Is a range of 5 models 1U or 2U rack-switches offering 20 to 96 interfaces running on 1 or 10 Gbit/s Ethernet and 10 Gbit/s FCoE interfaces. They can be used with the above-mentioned Nexus 2000 series fabric extender. The 5000-series offer carrier-grade layer2 and layer3 switching as well as FCoE capabilities The Nexus 5000 has 5 models: A two rack-unit high switch with 40 fixed 10 Gbit/s supporting Ethernet, FCoE and DCB and two expansion ports each offering one of

SECTION 10

#1732787350888

444-428: Is as such not a physical box but a software application that interacts with the hypervisor so you can virtualize the networking environment and be able to configure your system as if all virtual servers have connections to a physical switch and include the capabilities that a switch offers such as multiple VLANs per virtual interface, layer-3 options, security features etc. Per infrastructure/cluster you have one VM running

481-448: Is called a 19-inch rack unit, the actual mounting dimensions of a 19-inch rack unit are 18 5 ⁄ 16 inches (18.3125 in or 465.1 mm) wide, center to center. Rack units are universally the same, but the type of thread can vary depending on the rack. Mounting rails can be No. 10-32 tapped ( Unified Thread Standard ), No. 12-24 tapped, metric M6 threaded or universal square holes. Universal square holes are becoming

518-503: Is capable of building a route-table with up to 16000 prefixes, 8000 host-entries and 4000 multicast routes and up to 4096 VLANs are supported. On top of that a high number of ingress or egress ACLs can be configured. The 3064 has a single fan tray, two replaceable power-supplies on board and two separate out of band management interfaces. To connect the 3064 to the rest of the network the use of proprietary EtherChannel or Link aggregation using industry-standard LACP or IEEE 802.3ad

555-488: Is currently the only Nexus switch in the 3000-series utilizing merchant silicon. The 1U rack-switch with 1, 10 and 40 Gbit/s Ethernet interfaces is designed for use in colo center . Offers layer 2 and layer 3 capabilities at wire-speed for all 64 interfaces running in 10 Gbit/s. Layer3 routing protocols supported include static routes, RIP v2 , OSPF and BGP-4 . The switch-fabric can switch 2.28 Tbit/s and forward up to 950 million packets per second. The switch

592-505: Is different from Wikidata All article disambiguation pages All disambiguation pages Cisco Nexus switches#Nexus 2000 series All switches in the Nexus range run the modular NX-OS firmware/operating system on the fabric. NX-OS has some high-availability features compared to the well-known Cisco IOS . This platform is optimized for high-density 10 Gigabit Ethernet . Cisco Nexus OS Software Defined Networking (SDN) allows

629-444: Is number of rack units, the ideal formula for panel height is h = (1.75 n − 0.031) for calculating in inches, and h = (44.45 n − 0.794) for calculating in millimetres. Manufacturing allows for dimensions with less precision. The 19-inch rack format with rack units of 1.75 inches (44.45 mm) was established as a standard by AT&T around 1922 in order to reduce the space required for repeater and termination equipment in

666-730: Is supported with up to 32 port-channels with each up to 16 physical interfaces. The switch holds of 48 SFP+ for 1 Gbit/s or 10 Gbit/s Ethernet interfaces and four QSFP+ each handling 4 x 10 Gbit/s interfaces allowing for 40 Gbit/s over a single fibre-pair The Nexus 4000 series consists of only the model 4001: a blade -switch module for IBM BladeCenter that has all 10 Gbit FCoE interfaces. This blade switch had 14 server-facing downlinks running on 1 Gbit/s or 10 Gbit/s and six uplinks using 10 Gbit/s SFP+ modules. For out-of-band management, three Ethernet interfaces are available: one external 10/100/1000 bit/s copper interface, one internal management interface for

703-561: Is wire-speed at layer2 and 1.28 Tbit/s for layer3 operation. The 2nd model in the Nexus 6000 series is a modular chassis, 4 Rack units high. The basic chassis offers 48 fixed QSFP+ ports at 40 Gbit/s each, each can be split in 4 x 10 Gbit/s SFP+ ports. Besides the 48 QSFP+ ports the chassis can hold up to 4 expansion modules - each offering 12 additional 40 Gbit/s QSFP+ ports - thus in total up to 96 QSFP+ ports or 384 SFP+/10 Gbit/s ports and when aggregating FEX up to 1536 (blade)server ports at 1 or 10 Gbit/s. As with

740-701: The AMM or Advanced Management Module and one in-band interface using the VLAN interface option. And this blade-switch also has a serial console cable for direct access to the CLI At present only switches for the IBM blade systems are available. When the Nexus 4000 series were announced in 2009 it was expected that there would be Nexus 4001 series for IBM and Dell (and not HP) but in February 2010 it became clear that Cisco canceled

777-565: The 6001 layer 2/layer 3 operation is at line-rate and total switching capacity of a chassis is 7,68 Tbit/s. The Nexus 6004-EF switch is a modular device which provides the same features as the 6004 but with the use of expansion modules in all slots of the switch. The base configuration of the 6004-EF must have 2 x 12 port 40GbE expansion modules, delivering 24 ports of 40GbE or 96 ports of 10GbE. Additional capacity can be provided by installing further expansion modules. For layer3 and FCoE operation additional licences are required Cisco released

SECTION 20

#1732787350888

814-703: The Fabric Extenders (FEX) for different blade-server systems. Both models support either front to back or back to front airflow and they do support Fibre Channel over Ethernet in combination with a 'full' FCoE switch (e.g. Nexus 5500 or Brocade 8000 switch (which is same as Dell PowerConnect 8000e or blade version PCM 8428-k )). The Nexus 6001 is a fixed 1 RU switch with 48 x 10 Gbit/s and 4 x 40 Gbit/s interfaces for uplinks. It can operate as both layer2 and as layer3 switch and in combination with FEX (fabric extenders) you can aggregate up to 1152 ports at 1 Gbit/s or 10 Gbit/s. System speed

851-777: The HP BladeSystem C3000 and C7000 server blade chassis, the Cisco Nexus B22HP fabric extender exists. (October 2011) The Fujitsu PRIMERGY BX400 and BX900 blade server chassis uses the B22F fabric extender. (July 2012) For the Dell M1000e blade server chassis, the Cisco Nexus B22Dell fabric extender was released in January 2013, which is 2.5 years after the initially planned release. Due to

888-593: The NX-OS interface to configure, manage and monitor the virtual switch it also supports LACP link aggregation where the standard virtual switches only support static LAGs The configuration of VEMs is done via the VSM NX-OS Command-line interface . The Virtual Supervisor Module or VSM would normally run as a virtual appliance in an ESX/ESXi cluster but it is possible to run the VSM on dedicated hardware:

925-655: The Nexus 1000v as virtual appliance , this is the VSM or Virtual Supervisor Module and then on each node you would have a 'client' or Virtual Ethernet Module (VEM) a vSwitch which replaces the standard vSwitch. The VEM uses the vDS API , which was developed by VMware and Cisco together VMware announced in May 2017, vDS API support will be removed from vSphere 6.5 Update 2 and later. Therefore Nexus 1000v can no longer be used. VMware KB https://kb.vmware.com/s/article/2149722 https://www.theregister.co.uk/2017/03/31/vmware_to_end_support_for_thirdparty_virtual_switches/ Besides offering

962-507: The Nexus 1010, 1010x and 1100. For organisations where there is a very strict boundary between network management and server management, network administrators can avoid the dependency on the VSM running as virtual machine within the ESX cluster. The capabilities and limitations of a VSM running on a Nexus1010 are the same as a VSM running as virtual appliance under ESX. A Nexus 1100 can host up to 14 VSMs and it also allows additional services such as

999-622: The Nexus 2000 Fabric Extenders can act as a remote line card on the 7000 series. 70xx and 77xx linecards and supervisor modules are not compatible. The Nexus 9000 series is a range of many models 2U to 21U rack-switches offering 60 to 2304 interfaces running on 100Mb , 1Gb , 10Gb , 25Gb , 40Gb , 100Gb , 400Gb Ethernet, 10/25/40 Gb FCoE interfaces. They can be used with the above-mentioned Nexus 2000 series fabric extender. The 9000 series provides converged Active Directory (AD), Network Standard Execution, (NSX) and Application Centric Infrastructure (ACI) using Software Defined Networking (SDN) in

1036-415: The Nexus 2000 fabric extender to the 5500 range, the Nexus 7000 is the real modular switch in the Nexus family with six versions: one 4 slot, one 9 slot, two 10 slot and two 18 slot switches. Unlike the other Nexus models, the 7000 series switches are the modular switches for campus core and data center access, aggregation and core. Some details on the models are detailed below. As with the Nexus 5000 series

1073-622: The Nexus 4001d for the Dell M1000e For the HP blade system Cisco released a Fabric Extender, which compares with the Nexus 2000 top of rack devices, but then in a blade-form factor. The FEX that was developed for the Dell blade system, which was due to be released in the summer of 2010 was dropped at the same time as the Nexus 4001d in February of that year The Nexus 5000 series, a.k.a. N5K,

1110-484: The Nexus 6004X switch and renamed it to the Nexus 5696Q. Previously, the Nexus 6000 series was meant to be focused on the Cisco 40G aggregation products, and the 5500 and 5600 series on 10G. However, these switches mostly shared common hardware components, ASICs, and the same software images, so recently the Cisco decided to merge the product portfolios. Although the Nexus 5000 had some modular capabilities and you can attach

1147-464: The height of the frame or equipment is expressed as multiples of rack units. For example, a typical full-size rack cage is 42U high, while equipment is typically 1U, 2U, 3U, or 4U high. The rack unit size is based on a standard rack specification as defined in EIA -310. The Eurocard specifies a standard rack unit as the unit of height; it also defines a similar unit, horizontal pitch (HP), used to measure

Fex - Misplaced Pages Continue

1184-588: The modules The 5548 comes in two sub-models: the 5548P and 5548UP The 5596 comes in two sub-models the UP and the T: Next to the expansion modules all three Nexus 55xx switches offer the capability to insert a 160 Gbit/s layer-3 routing engine The 5672UP comes in two variants, with 16 or 24 unified ports: The Cisco Nexus 6000 range contains two models, the 6001 model and the 6004 model. They can be used as layer2 and layer3 switches and can aggregate traffic from

1221-402: The most common as these allow the insertion of replaceable cage nuts for the type of thread needed. This prevents stripping of the threading on the rails and allows for more flexibility. Whereas there is no formal specification for "half rack", the term half-rack can have different separate meanings: It can describe equipment that fits in a certain number of rack units, but occupy only half

1258-443: The same policies that govern Identity and Access Management (IAM) to dictate levels of access to applications and data through a totally converged infrastructure not possible with legacy network and system access methods. The Nexus 9000 is the high-end model in the Nexus range of datacenter switches. Other models are: The 1000v is a virtual switch for use in virtual environments including both VMware vSphere and Microsoft Hyper-V It

1295-403: The same term [REDACTED] This disambiguation page lists articles associated with the title Fex . If an internal link led you here, you may wish to change the link to point directly to the intended article. Retrieved from " https://en.wikipedia.org/w/index.php?title=Fex&oldid=1256870144 " Category : Disambiguation pages Hidden categories: Short description

1332-405: The width of a 19-inch rack (9.5 inches (241.30 mm)). These are commonly used when a piece of equipment does not require full rack width, but may require more than 1U of height. For example, a "4U half-rack" DVCAM deck occupies 4U (7 in) height × 9.5 in width, and in theory, two 4U half-rack decks could be mounted side by side and occupy the 4U space. It can also describe a unit that

1369-460: The width of rack-mounted equipment. The standard was adopted worldwide as IEC 60297 Mechanical structures for electronic equipment – Dimensions of mechanical structures of the 482.6 mm (19 in) series , and defines the sizes for rack, subrack (a shelf-like chassis in which cards can be inserted), and the pitch of printed circuit boards /cards providing physical compatibility of technological equipment, typically in telecommunications. While

#887112