Computer-aided architectural design (CAAD) software programs are the repository of accurate and comprehensive records of buildings and are used by architects and architectural companies for architectural design and architectural engineering . As the latter often involve floor plan designs CAAD software greatly simplifies this task.
112-449: The first attempts to computerize the architectural design date back to the 1960s: The first attempts to separate the CAAD from generic CAD were made in the 1970s. The practical commercial tools for architecture design and building information modeling appeared a decade later, in the 1980s. Due to availability of the tools, computerized design in architecture became a distinct field within
224-707: A file of punched cards ." In February 1950, in a Radio Corporation of America (RCA) advertisement in Popular Science magazine describing a new "memory" vacuum tube it had developed, RCA stated: "the results of countless computations can be kept 'on file' and taken out again. Such a 'file' now exists in a 'memory' tube developed at RCA Laboratories. Electronically it retains figures fed into calculating machines, holds them in storage while it memorizes new ones – speeds intelligent solutions through mazes of mathematics." In 1952, "file" denoted, among other things, information stored on punched cards . In early use,
336-475: A database with geometric and other properties of objects; they all have some kind of graphic user interface to manipulate a visual representation rather than the database; and they are all more or less concerned with assembling designs from standard and non-standard pieces. Currently, the main distinction which causes one to speak of CAAD rather than CAD lies in the domain knowledge (architecture-specific objects, techniques, data, and process support) embedded in
448-462: A hard disk . Hard disks have been the ubiquitous form of non-volatile storage since the early 1960s. Where files contain only temporary information, they may be stored in RAM . Computer files can be also stored on other media in some cases, such as magnetic tapes , compact discs , Digital Versatile Discs , Zip drives , USB flash drives , etc. The use of solid state drives is also beginning to rival
560-428: A link to the file. There can be many links to a file, but when they are all removed, the kernel considers that file's memory space free to be reallocated. This free space is commonly considered a security risk (due to the existence of file recovery software ). Any secure-deletion program uses kernel-space (system) functions to wipe the file's data. File moves within a file system complete almost immediately because
672-904: A white paper entitled "Building Information Modeling," and other software vendors also started to assert their involvement in the field. By hosting contributions from Autodesk, Bentley Systems and Graphisoft, plus other industry observers, in 2003, Jerry Laiserin helped popularize and standardize the term as a common name for the digital representation of the building process. As some BIM software developers have created proprietary data structures in their software, data and files created by one vendor's applications may not work in other vendor solutions. To achieve interoperability between applications, neutral, non-proprietary or open standards for sharing BIM data among different software applications have been developed. Poor software interoperability has long been regarded as an obstacle to industry efficiency in general and to BIM adoption in particular. In August 2004
784-560: A 1992 paper by G.A. van Nederveen and F. P. Tolman. However, the terms 'Building Information Model' and 'Building Information Modeling' (including the acronym "BIM") did not become popularly used until some 10 years later. Facilitating exchange and interoperability of information in digital format was variously with differing terminology: by Graphisoft as "Virtual Building" or "Single Building Model", Bentley Systems as "Integrated Project Models", and by Autodesk or Vectorworks as "Building Information Modeling". In 2002, Autodesk released
896-454: A FAT extension allowing long file names). File manager programs are utility programs that allow users to manipulate files directly. They allow you to move, create, delete and rename files and folders, although they do not actually allow you to read the contents of a file or store information in it. Every computer system provides at least one file-manager program for its native file system. For example, File Explorer (formerly Windows Explorer)
1008-431: A US National Institute of Standards and Technology ( NIST ) report conservatively estimated that $ 15.8 billion was lost annually by the U.S. capital facilities industry due to inadequate interoperability arising from "the highly fragmented nature of the industry, the industry’s continued paper-based business practices, a lack of standardization, and inconsistent technology adoption among stakeholders". An early BIM standard
1120-546: A building model for drawing production and other uses. These different views are automatically consistent, being based on a single definition of each object instance. BIM software also defines objects parametrically; that is, the objects are defined as parameters and relations to other objects so that if a related object is amended, dependent ones will automatically also change. Each model element can carry attributes for selecting and ordering them automatically, providing cost estimates as well as material tracking and ordering. For
1232-400: A built asset. BIM software is used by individuals, businesses and government agencies who plan, design , construct , operate and maintain buildings and diverse physical infrastructures , such as water, refuse, electricity, gas, communication utilities, roads, railways, bridges, ports and tunnels. The concept of BIM has been in development since the 1970s, but it only became an agreed term in
SECTION 10
#17327907410551344-410: A current word and was a common topic of commercial modernization. CAAD has two types of structures in its program. The first system is surface structure which provides a graphics medium to represent three-dimensional objects using two-dimensional representations. Also algorithms that allow the generation of patterns and their analysis using programmed criteria, and data banks that store information about
1456-427: A device, no space will have been freed up on the source device or partition. The user would need to merge the remaining files from the source, including the incompletely written (truncated) last file. With the individual deletion method, the file moving software also does not need to cumulatively keep track of all files finished transferring for the case that a user manually aborts the file transfer. A file manager using
1568-524: A directory and a file. In environments in which a file is named, a file's name and the path to the file's directory must uniquely identify it among all other files in the computer system—no two files can have the same name and path. Where a file is anonymous, named references to it will exist within a namespace. In most cases, any name within the namespace will refer to exactly zero or one file. However, any file may be represented within any namespace by zero, one or more names. Any string of characters may be
1680-847: A dot (period) at the end of a file name, followed by a few letters to identify the type of file. An extension of .txt identifies a text file; a .doc extension identifies any type of document or documentation, commonly in the Microsoft Word file format ; and so on . Even when extensions are used in a computer system, the degree to which the computer system recognizes and heeds them can vary; in some systems, they are required, while in other systems, they are completely ignored if they are presented. Many modern computer systems provide methods for protecting files against accidental and deliberate damage. Computers that allow for multiple users implement file permissions to control who may or may not modify, delete, or create files and folders. For example,
1792-514: A given user may be granted only permission to read a file or folder, but not to modify or delete it; or a user may be given permission to read and modify files or folders, but not to execute them. Permissions may also be used to allow only certain users to see the contents of a file or folder. Permissions protect against unauthorized tampering or destruction of information in files, and keep private information confidential from unauthorized users. Another protection mechanism implemented in many computers
1904-567: A graphical approach. Only this form of expression serves as a basis for work and discussion. Therefore, the designer should have maximum visual control over the processes taking place within the design continuum. Further questions occur about navigation, associative information access, programming and communication within very large data sets. Several organisations are active in education and research in CAAD: Building information modeling Building information modeling ( BIM )
2016-446: A later point through overwriting. There are many ways by which a file can become corrupted. Most commonly, the issue happens in the process of writing the file to a disk . For example, if an image-editing program unexpectedly crashes while saving an image, that file may be corrupted because the program could not save its entirety. The program itself might warn the user that there was an error, allowing for another attempt at saving
2128-420: A low level, on a file. Only the kernel deals with files, and it handles all user-space interaction with files in a manner that is transparent to the user-space programs. The operating system provides a level of abstraction , which means that interaction with a file from user-space is simply through its filename (instead of its inode ). For example, rm filename will not delete the file itself, but only
2240-482: A model during design. One of the challenges to the proper maintenance and management of existing facilities is understanding how BIM can be utilized to support a holistic understanding and implementation of building management practices and " cost of ownership " principles that support the full product lifecycle of a building. An American National Standard entitled APPA 1000 – Total Cost of Ownership for Facilities Asset Management incorporates BIM to factor in
2352-406: A name of its own, but also a path, which identifies the folder or folders in which a file or folder resides. In the path, some sort of special character—such as a slash—is used to separate the file and folder names. For example, in the illustration shown in this article, the path /Payroll/Salaries/Managers uniquely identifies a file called Managers in a folder called Salaries , which in turn
SECTION 20
#17327907410552464-576: A national key research and application project in "12th Five-Year" Science and Technology Development Planning. Therefore, the year 2011 was described as "The First Year of China's BIM" . In 2006 the Hong Kong Housing Authority introduced BIM, and then set a target of full BIM implementation in 2014/2015. BuildingSmart Hong Kong was inaugurated in Hong Kong SAR in late April 2012. The Government of Hong Kong mandates
2576-418: A number of bytes , that indicates how much storage is occupied by the file. In most modern operating systems the size can be any non-negative whole number of bytes up to a system limit. Many older operating systems kept track only of the number of blocks or tracks occupied by a file on a physical storage device. In such systems, software employed other methods to track the exact byte count (e.g., CP/M used
2688-443: A payroll file might contain information concerning all the employees in a company and their payroll details; each record in the payroll file concerns just one employee, and all the records have the common trait of being related to payroll—this is very similar to placing all payroll information into a specific filing cabinet in an office that does not have a computer. A text file may contain lines of text, corresponding to printed lines on
2800-429: A piece of paper. Alternatively, a file may contain an arbitrary binary image (a blob ) or it may contain an executable . The way information is grouped into a file is entirely up to how it is designed. This has led to a plethora of more or less standardized file structures for all imaginable purposes, from the simplest to the most complex. Most computer files are used by computer programs which create, modify or delete
2912-569: A relative scale with the entire facility or group of facilities. BIM also prevents errors by enabling conflict or 'clash detection' whereby the computer model visually highlights to the team where parts of the building (e.g.:structural frame and building services pipes or ducts) may wrongly intersect. BIM can bridge the information loss associated with handing a project from design team, to construction team and to building owner/operator, by allowing each group to add to and reference back to all information they acquire during their period of contribution to
3024-400: A single environment, better coordination and development of designs, enhanced clash avoidance and detection, and improved time and cost decision-making. "BIM wash" or "BIM washing" is a term sometimes used to describe inflated, and/or deceptive, claims of using or delivering BIM services or products. Use of BIM goes beyond the planning and design phase of the project, extending throughout
3136-433: A special control character, Ctrl-Z , to signal the end of text files). The general definition of a file does not require that its size have any real meaning, however, unless the data within the file happens to correspond to data within a pool of persistent storage. A special case is a zero byte file ; these files can be newly created files that have not yet had any data written to them, or may serve as some kind of flag in
3248-738: A timetable for the introduction of mandatory BIM for German road and rail projects from the end of 2020. Speaking in April 2016, he said digital design and construction must become standard for construction projects in Germany, with Germany two to three years behind The Netherlands and the UK in aspects of implementing BIM. BIM was piloted in many areas of German infrastructure delivery and in July 2022 Volker Wissing , Federal Minister for Digital and Transport , announced that, from 2025, BIM will be used as standard in
3360-438: A tree-like structure in which one "master folder" (or "root folder" — the name varies from one operating system to another) can contain any number of levels of other folders and files. Folders can be named just as files can (except for the root folder, which often does not have a name). The use of folders makes it easier to organize files in a logical way. When a computer allows the use of folders, each file and folder has not only
3472-469: A variety of critical requirements and costs over the life-cycle of the building, including but not limited to: replacement of energy, utility, and safety systems; continual maintenance of the building exterior and interior and replacement of materials; updates to design and functionality; and recapitalization costs. BIM in green building , or "green BIM", is a process that can help architecture, engineering and construction firms to improve sustainability in
Computer-aided architectural design - Misplaced Pages Continue
3584-419: A well-formed name for a file or a link depending upon the context of application. Whether or not a name is well-formed depends on the type of computer system being used. Early computers permitted only a few letters or digits in the name of a file, but modern computers allow long names (some up to 255 characters) containing almost any combination of Unicode letters or Unicode digits, making it easier to understand
3696-444: A written message, a document, a spreadsheet , an image , a video , a program , or any wide variety of other kinds of data. Certain files can store multiple data types at once. By using computer programs, a person can open, read, change, save, and close a computer file. Computer files may be reopened, modified, and copied an arbitrary number of times. Files are typically organized in a file system , which tracks file locations on
3808-560: A year. Computer files In computing , a computer file is a resource for recording data on a computer storage device , primarily identified by its filename . Just as words can be written on paper, so too can data be written to a computer file. Files can be shared with and transferred between computers and mobile devices via removable media , networks , or the Internet . Different types of computer files are designed for different purposes. A file may be designed to store
3920-436: Is a read-only flag. When this flag is turned on for a file (which can be accomplished by a computer program or by a human user), the file can be examined, but it cannot be modified. This flag is useful for critical information that must not be modified or erased, such as special files that are used only by internal parts of the computer system. Some systems also include a hidden flag to make certain files invisible; this flag
4032-482: Is also associated with BIM. COBie was devised by Bill East of the United States Army Corps of Engineers in 2007, and helps capture and record equipment lists, product data sheets, warranties, spare parts lists, and preventive maintenance schedules. This information is used to support operations, maintenance and asset management once a built asset is in service. In December 2011, it was approved by
4144-460: Is an approach involving the generation and management of digital representations of the physical and functional characteristics of buildings and other physical assets. BIM is supported by various tools, processes, technologies and contracts. Building information models (BIMs) are computer files (often but not always in proprietary formats and containing proprietary data) which can be extracted, exchanged or networked to support decision-making regarding
4256-479: Is an area of memory which is manipulated to establish a filename etc. and then passed to the operating system as a parameter; it was used by older IBM operating systems and early PC operating systems including CP/M and early versions of MS-DOS . A file handle is generally either an opaque data type or an integer; it was introduced in around 1961 by the ALGOL-based Burroughs MCP running on
4368-403: Is being popular thanks to the developments in graphic cards. The exact distinction of what properly belongs to CAAD is not always clear. Specialized software, for example for calculating structures by means of the finite element method , is used in architectural design and in that sense may fall under CAAD. On the other hand, such software is seldom used to create new designs. In 1974 Caad became
4480-420: Is contained in a folder called Payroll . The folder and file names are separated by slashes in this example; the topmost or root folder has no name, and so the path begins with a slash (if the root folder had a name, it would precede this first slash). Many computer systems use extensions in file names to help identify what they contain, also known as the file type. On Windows computers, extensions consist of
4592-464: Is corrupted. There are services that provide on demand file corruption, which essentially fill a given file with random data so that it cannot be opened or read, yet still seems legitimate. One of the most effective countermeasures for unintentional file corruption is backing up important files. In the event of an important file becoming corrupted, the user can simply replace it with the backed up version. When computer files contain information that
Computer-aided architectural design - Misplaced Pages Continue
4704-613: Is extremely important, a back-up process is used to protect against disasters that might destroy the files. Backing up files simply means making copies of the files in a separate location so that they can be restored if something happens to the computer, or if they are deleted accidentally. There are many ways to back up files. Most computer systems provide utility programs to assist in the back-up process, which can become very time-consuming if there are many files to safeguard. Files are often copied to removable media such as writable CDs or cartridge tapes. Copying files to another hard disk in
4816-956: Is not currently active, IBIMA aims to share knowledge resources to support construction engineering management decision-making. BIM implementation is targeted towards BIM Stage 2 by the year 2020 led by the Construction Industry Development Board (CIDB Malaysia). Under the Construction Industry Transformation Plan (CITP 2016–2020), it is hoped more emphasis on technology adoption across the project life-cycle will induce higher productivity. The Building and Construction Authority (BCA) has announced that BIM would be introduced for architectural submission (by 2013), structural and M&E submissions (by 2014) and eventually for plan submissions of all projects with gross floor area of more than 5,000 square meters by 2015. The BCA Academy
4928-409: Is retained by a design build team on the client's behalf from the pre-design phase onwards to develop and to track the object-oriented BIM against predicted and measured performance objectives, supporting multi-disciplinary building information models that drive analysis, schedules, take-off and logistics. Companies are also now considering developing BIMs in various levels of detail, since depending on
5040-498: Is the typical statement, which is to develop a computer based functionality that maps as closely as possible into a corresponding manual design activity, for example, drafting of stairs, checking spatial conflict between building systems, and generating perspectives from orthogonal views. The architectural design processes tend to integrate models isolated so far. Many different kinds of expert knowledge, tools, visualization techniques, and media are to be combined. The design process covers
5152-583: Is training students in BIM. The Ministry of Land, Infrastructure and Transport (MLIT) has announced "Start of BIM pilot project in government building and repairs" (by 2010). Japan Institute of Architects (JIA) released the BIM guidelines (by 2012), which showed the agenda and expected effect of BIM to architects. MLIT announced " BIM will be mandated for all of its public works from the fiscal year of 2023, except those having particular reasons". The works subject to WTO Government Procurement Agreement shall comply with
5264-435: Is used by the computer system to hide essential system files that users should not alter. Any file that has any useful purpose must have some physical manifestation. That is, a file (an abstract concept) in a real computer system must have a real physical analogue if it is to exist at all. In physical terms, most computer files are stored on some type of data storage device. For example, most operating systems store files on
5376-431: Is used to share data across a project or asset lifecycle, supporting collaboration across a whole project team. The concept of a CDE overlaps with enterprise content management , ECM, but with a greater focus on BIM issues. Building information models span the whole concept-to-occupation time-span. To ensure efficient management of information processes throughout this span, a BIM manager might be appointed. The BIM manager
5488-627: The mv command for instance, the former method is used when selecting files individually, possibly with the use of wildcards (example: mv -n sourcePath/* targetPath , while the latter method is used when selecting entire directories (example: mv -n sourcePath targetPath ). Microsoft Windows Explorer uses the former method for mass storage file moves, but the latter method using Media Transfer Protocol , as described in Media Transfer Protocol § File move behavior . The former method (individual deletion from source) has
5600-468: The Burroughs B5000 but is now ubiquitous. When a file is said to be corrupted, it is because its contents have been saved to the computer in such a way that they cannot be properly read, either by a human or by software. Depending on the extent of the damage, the original file can sometimes be recovered , or at least partially understood. A file may be created corrupt, or it may be corrupted at
5712-648: The Facility Condition Index (FCI), or using 3D laser-scanning surveys and photogrammetry techniques (separately or in combination) or digitizing traditional building surveying methodologies by using mobile technology to capture accurate measurements and operation-related information about the asset that can be used as the basis for a model. Trying to retrospectively model a building constructed in, say 1927, requires numerous assumptions about design standards, building codes, construction methods, materials, etc, and is, therefore, more complex than building
SECTION 50
#17327907410555824-619: The NTFS file system that is the normal file system for recent versions of Windows. Each system has its own advantages and disadvantages. Standard FAT allows only eight-character file names (plus a three-character extension) with no spaces, for example, whereas NTFS allows much longer names that can contain spaces. You can call a file " Payroll records " in NTFS, but in FAT you would be restricted to something like payroll.dat (unless you were using VFAT ,
5936-495: The 1970s. The first software tools developed for modeling buildings emerged in the late 1970s and early 1980s, and included workstation products such as Chuck Eastman 's Building Description System and GLIDE, RUCAPS , Sonata , Reflex and Gable 4D Series . The early applications, and the hardware needed to run them, were expensive, which limited widespread adoption. The pioneering role of applications such as RUCAPS, Sonata and Reflex has been recognized by Laiserin as well as
6048-470: The BIM model. Enabling an effective handover of information from design and construction (including via IFC or COBie) can thus yield benefits to the facility owner or operator. BIM-related processes relating to longer-term asset management are also covered in ISO-19650 Part 3. For example, a building owner may find evidence of a water leak in a building. Rather than exploring the physical building,
6160-574: The Korean government has been gradually increasing the scope of BIM-mandated projects. McGraw Hill published a detailed report in 2012 on the status of BIM adoption and implementation in South Korea. Dubai Municipality issued a circular (196) in 2014 mandating BIM use for buildings of a certain size, height or type. The one page circular initiated strong interest in BIM and the market responded in preparation for more guidelines and direction. In 2015
6272-477: The Municipality issued another circular (207) titled 'Regarding the expansion of applying the (BIM) on buildings and facilities in the emirate of Dubai' which made BIM mandatory on more projects by reducing the minimum size and height requirement for projects requiring BIM. This second circular drove BIM adoption further with several projects and organizations adopting UK BIM standards as best practice. In 2016,
6384-491: The UAE's Quality and Conformity Commission set up a BIM steering group to investigate statewide adoption of BIM. Austrian standards for digital modeling are summarized in the ÖNORM A 6241, published on 15 March 2015. The ÖNORM A 6241-1 (BIM Level 2), which replaced the ÖNORM A 6240-4, has been extended in the detailed and executive design stages, and corrected in the lack of definitions. The ÖNORM A 6241-2 (BIM Level 3) includes all
6496-510: The UK's Royal Academy of Engineering ; former GMW employee Jonathan Ingram worked on all three products. What became known as BIM products differed from architectural drafting tools such as AutoCAD by allowing the addition of further information (time, cost, manufacturers' details, sustainability, and maintenance information, etc.) to the building model. As Graphisoft had been developing such solutions for longer than its competitors, Laiserin regarded its ArchiCAD application as then "one of
6608-504: The US-based National Institute of Building Sciences as part of its National Building Information Model (NBIMS-US) standard. COBie has been incorporated into software, and may take several forms including spreadsheet, IFC, and ifcXML. In early 2013 BuildingSMART was working on a lightweight XML format, COBieLite, which became available for review in April 2013. In September 2014, a code of practice regarding COBie
6720-524: The application of BIM, more or less detail is needed, and there is varying modeling effort associated with generating building information models at different levels of detail. Participants in the building process are constantly challenged to deliver successful projects despite tight budgets, limited staffing, accelerated schedules, and limited or conflicting information. The significant disciplines such as architectural , structural and MEP designs should be well-coordinated, as two things can't take place at
6832-793: The architecture. The intervening years were characterized by the rapid growth in the research: the Design Methods conference (1962) had put the design research on the map, the 1st International Congress on Performance (1972) discussed the early approaches to computerizing the building performance simulations. New research journals had focused on the subject in the 1990s and 2000s: Automation in Construction (1992), International Journal of Architectural Computing (2003), Journal of Building Performance Simulation (2008). Architectural Design and Design Studies, established in 1979, gradually moved to CAAD. Computer-aided design also known as CAD
SECTION 60
#17327907410556944-410: The archive file are to lower the number of files for easier transfer, to reduce storage usage, or just to organize outdated files. The archive file must often be unpacked before next using. The most basic operations that programs can perform on a file are: Files on a computer can be created, moved, modified, grown, shrunk ( truncated ), and deleted. In most cases, computer programs that are executed on
7056-407: The benefit that space is released from the source device or partition imminently after the transfer has begun, meaning after the first file is finished. With the latter method, space is only freed after the transfer of the entire selection has finished. If an incomplete file transfer with the latter method is aborted unexpectedly, perhaps due to an unexpected power-off, system halt or disconnection of
7168-456: The building life cycle. The supporting processes of building lifecycle management include cost management , construction management , project management , facility operation and application in green building . A 'Common Data Environment' (CDE) is defined in ISO 19650 as an: A CDE workflow describes the processes to be used while a CDE solution can provide the underlying technologies. A CDE
7280-399: The built asset from initial planning through to construction and then throughout its operational life. BIM authoring tools present a design as combinations of "objects" – vague and undefined, generic or product-specific, solid shapes or void-space oriented (like the shape of a room), that carry their geometry, relations, and attributes. BIM applications allow extraction of different views from
7392-464: The built environment. It can allow architects and engineers to integrate and analyze environmental issues in their design over the life cycle of the asset. China began its exploration on informatisation in 2001. The Ministry of Construction announced BIM was as the key application technology of informatisation in "Ten new technologies of construction industry" (by 2010). The Ministry of Science and Technology (MOST) clearly announced BIM technology as
7504-430: The cluster is to develop an innovative digital construction environment as well as VDC new product development , Grid and e-construction portal to increase the international competitiveness and sales of Estonian businesses in the construction field. The cluster is equally co-funded by European Structural and Investment Funds through Enterprise Estonia and by the members of the cluster with a total budget of 600 000 euros for
7616-426: The complete life cycle of the building. The areas that are covered are construction, operations, reorganization, as well as destruction. Considering the shared use of digital design tools and the exchange of information and knowledge between designers and across different projects, we speak of a design continuum. An architect's work involves mostly visually represented data. Problems are often outlined and dealt with in
7728-559: The computer handle these operations, but the user of a computer can also manipulate files if necessary. For instance, Microsoft Word files are normally created and modified by the Microsoft Word program in response to user commands, but the user can also move, rename , or delete these files directly by using a file manager program such as Windows Explorer (on Windows computers) or by command lines (CLI). In Unix-like systems, user space programs do not operate directly, at
7840-496: The construction of federal trunk roads in addition to the rail sector. In November 2017, Ireland's Department for Public Expenditure and Reform launched a strategy to increase use of digital technology in delivery of key public works projects, requiring the use of BIM to be phased in over the next four years. Through the new D.l. 50, in April 2016 Italy has included into its own legislation several European directives including 2014/24/EU on Public Procurement. The decree states among
7952-410: The data content does not need to be rewritten. Only the paths need to be changed. There are two distinct implementations of file moves. When moving files between devices or partitions, some file managing software deletes each selected file from the source directory individually after being transferred, while other software deletes all files at once only after every file has been transferred. With
8064-706: The disk and enables user access. The word "file" derives from the Latin filum ("a thread, string"). "File" was used in the context of computer storage as early as January 1940. In Punched Card Methods in Scientific Computation , W. J. Eckert stated, "The first extensive use of the early Hollerith Tabulator in astronomy was made by Comrie . He used it for building a table from successive differences, and for adding large numbers of harmonic terms". "Tables of functions are constructed from their differences with great efficiency, either as printed tables or as
8176-440: The document file is arranged in a format that the word-processing program understands, the user is able to choose the name and location of the file and provide the bulk of the information (such as words and text) that will be stored in the file. Many applications pack all their data files into a single file called an archive file , using internal markers to discern the different types of information contained within. The benefits of
8288-617: The early 2000s. The development of standards and the adoption of BIM has progressed at different speeds in different countries. Developed by buildingSMART , Industry Foundation Classes (IFCs) – data structures for representing information – became an international standard, ISO 16739, in 2013, and BIM process standards developed in the United Kingdom from 2007 onwards formed the basis of an international standard, ISO 19650, launched in January 2019. The concept of BIM has existed since
8400-403: The existence of directory hierarchies, i.e., directories containing sub-directories. A name that refers to a file within a directory must be typically unique. In other words, there must be no identical names within a directory. However, in some operating systems, a name may include a specification of type that means a directory can contain an identical name for more than one type of object such as
8512-414: The file and the son is the current copy. The way a computer organizes, names, stores and manipulates files is globally referred to as its file system . Most computers have at least one file system. Some computers allow the use of several different file systems. For instance, on newer MS Windows computers, the older FAT-type file systems of MS-DOS and old versions of Windows are supported, in addition to
8624-414: The file system) file-specific data outside of the file format, but linked to the file, for example extended attributes or forks . On other file systems this can be done via sidecar files or software-specific databases. All those methods, however, are more susceptible to loss of metadata than container and archive file formats. At any instant in time, a file has a specific size, normally expressed as
8736-526: The file system, or are accidents (the results of aborted disk operations). For example, the file to which the link /bin/ls points in a typical Unix-like system probably has a defined size that seldom changes. Compare this with /dev/null which is also a file, but as a character special file , its size is not meaningful. Information in a computer file can consist of smaller packets of information (often called " records " or "lines") that are individually different but share some common traits. For example,
8848-423: The file. Some other examples of reasons for which files become corrupted include: Although file corruption usually happens accidentally, it may also be done on purpose as a mean of procrastination , as to fool someone else into thinking an assignment was ready at an earlier date, potentially gaining time to finish said assignment or making experiments, with the purpose of documenting the consequences when such file
8960-402: The files for their own use on an as-needed basis. The programmers who create the programs decide what files are needed, how they are to be used and (often) their names. In some cases, computer programs manipulate files that are made visible to the computer user. For example, in a word-processing program , the user manipulates document files that the user personally names. Although the content of
9072-472: The functionalities that are found at the surface. Another advantage to CAAD is the two way mapping of activities and functionalities. The two instances of mapping are indicated to be between the surface structures and the deep structures. These mappings are abstractions that are introduced in order to discuss the process of design and deployment of CAAD systems. In designing the systems the system developers usually consider surface structures. A one-to-one mapping
9184-439: The hard disk drive. In Unix-like operating systems, many files have no associated physical storage device. Examples are /dev/null and most files under directories /dev , /proc and /sys . These are virtual files: they exist as objects within the operating system kernel. As seen by a running user program, files are usually represented either by a file control block or by a file handle . A file control block (FCB)
9296-789: The identification of vulnerabilities in building emergencies. Dynamic information about the building, such as sensor measurements and control signals from the building systems, can also be incorporated within software to support analysis of building operation and maintenance. As such, BIM in facility operation can be related to internet of things approaches; rapid access to data may also be aided by use of mobile devices (smartphones, tablets) and machine-readable RFID tags or barcodes ; while integration and interoperability with other business systems - CAFM , ERP , BMS , IWMS , etc - can aid operational reuse of data. There have been attempts at creating information models for older, pre-existing facilities. Approaches include referencing key metrics such as
9408-620: The late 1990s, with inputs from Georgia Tech , and was approved by the American Institute of Steel Construction as its data exchange format for structural steel in 2000. BIM is often associated with Industry Foundation Classes (IFCs) and aecXML – data structures for representing information – developed by buildingSMART . IFC is recognised by the ISO and has been an official international standard, ISO 16739, since 2013. Construction Operations Building information exchange ( COBie )
9520-418: The latter (afterwards deletion) method will have to only delete the files from the source directory that have already finished transferring. In modern computer systems, files are typically accessed using names ( filenames ). In some operating systems, the name is associated with the file itself. In others, the file is anonymous, and is pointed to by links that have names. In the latter case, a user can identify
9632-451: The main goals of public procurement the "rationalization of designing activities and of all connected verification processes, through the progressive adoption of digital methods and electronic instruments such as Building and Infrastructure Information Modelling". A norm in 8 parts is also being written to support the transition: UNI 11337-1, UNI 11337-4 and UNI 11337-5 were published in January 2017, with five further chapters to follow within
9744-478: The matured definition of 'BIM' specified only about one and a half decade later". The term 'building model' (in the sense of BIM as used today) was first used in papers in the mid-1980s: in a 1985 paper by Simon Ruffle eventually published in 1986, and later in a 1986 paper by Robert Aish – then at GMW Computers Ltd , developer of RUCAPS software – referring to the software's use at London's Heathrow Airport . The term 'Building Information Model' first appeared in
9856-400: The model before beginning construction, with opportunities to pre-fabricate or pre-assemble some systems off-site. Waste can be minimised on-site and products delivered on a just-in-time basis rather than being stock-piled on-site. Quantities and shared properties of materials can be extracted easily. Scopes of work can be isolated and defined. Systems, assemblies and sequences can be shown in
9968-517: The most mature BIM solutions on the market." Following its launch in 1987, ArchiCAD became regarded by some as the first implementation of BIM , as it was the first CAD product on a personal computer able to create both 2D and 3D geometry, as well as the first commercial BIM product for personal computers. However, Graphisoft founder Gábor Bojár has acknowledged to Jonathan Ingram in an open letter, that Sonata "was more advanced in 1986 than ArchiCAD at that time", adding that it "surpassed already
10080-413: The name of the link with the file itself, but this is a false analogue, especially where there exists more than one link to the same file. Files (or links to files) can be located in directories. However, more generally, a directory can contain either a list of files or a list of links to files. Within this definition, it is of paramount importance that the term "file" includes directories. This permits
10192-430: The owner may turn to the model and see that a water valve is located in the suspect location. The owner could also have in the model the specific valve size, manufacturer, part number, and any other information ever researched in the past, pending adequate computing power. Such problems were initially addressed by Leite and Akinci when developing a vulnerability representation of facility contents and threats for supporting
10304-549: The period 2016–2018. The French arm of buildingSMART , called Mediaconstruct (existing since 1989), is supporting digital transformation in France. A building transition digital plan – French acronym PTNB – was created in 2013 (mandated since 2015 to 2017 and under several ministries). A 2013 survey of European BIM practice showed France in last place, but, with government support, in 2017 it had risen to third place with more than 30% of real estate projects carried out using BIM. PTNB
10416-420: The problem at hand and the standards and regulations that applies to it. The second system is deep structure which means that the operations performed by the computer have natural limitations. Computer hardware and machine languages that are supported by these make it easy to perform arithmetical operations quickly and accurately. Also an almost illogical number of layers of symbolic processing can be built enabling
10528-518: The professionals involved in a project, BIM enables a virtual information model to be shared by the design team ( architects , landscape architects , surveyors , civil , structural and building services engineers , etc.), the main contractor and subcontractors , and the owner/operator. Each professional adds discipline-specific data to the shared model – commonly, a 'federated' model which combines several different disciplines' models into one. Combining models enables visualisation of all models in
10640-512: The prospect of integrating BIM with complementary international standards based classification systems being developed for the Power Plant sector. ISO 19650-1:2018 defines BIM as: The US National Building Information Model Standard Project Committee has the following definition: Traditional building design was largely reliant upon two-dimensional technical drawings (plans, elevations, sections, etc.). Building information modeling extends
10752-564: The published ISO standards related to BIM such as ISO19650 series as determined by the Article 10 (Technical Specification) of the Agreement. Small BIM-related seminars and independent BIM effort existed in South Korea even in the 1990s. However, it was not until the late 2000s that the Korean industry paid attention to BIM. The first industry-level BIM conference was held in April 2008, after which, BIM has been spread very rapidly. Since 2010,
10864-518: The purpose of a file at a glance. Some computer systems allow file names to contain spaces; others do not. Case-sensitivity of file names is determined by the file system . Unix file systems are usually case sensitive and allow user-level applications to create files whose names differ only in the case of characters. Microsoft Windows supports multiple file systems, each with different policies regarding case-sensitivity. The common FAT file system can have multiple files whose names differ only in case if
10976-559: The requirements for the BIM Level 3 (iBIM). The Czech BIM Council, established in May 2011, aims to implement BIM methodologies into the Czech building and designing processes, education, standards and legislation. In Estonia digital construction cluster (Digitaalehituse Klaster) was formed in 2015 to develop BIM solutions for the whole life-cycle of construction. The strategic objective of
11088-513: The rules for how the bytes must be organized and interpreted meaningfully. For example, the bytes of a plain text file ( .txt in Windows) are associated with either ASCII or UTF-8 characters, while the bytes of image, video, and audio files are interpreted otherwise. Most file types also allocate a few bytes for metadata , which allows a file to carry some basic information about itself. Some file systems can store arbitrary (not interpreted by
11200-402: The same computer protects against failure of one disk, but if it is necessary to protect against failure or destruction of the entire computer, then copies of the files must be made on other media that can be taken away from the computer and stored in a safe, distant location. The grandfather-father-son backup method automatically makes three back-ups; the grandfather file is the oldest copy of
11312-419: The same place and time. BIM additionally is able to aid in collision detection, identifying the exact location of discrepancies. The BIM concept envisages virtual construction of a facility prior to its actual physical construction, in order to reduce uncertainty, improve safety, work out problems, and simulate and analyze potential impacts. Sub-contractors from every trade can input critical information into
11424-511: The system. A CAAD system differs from other CAD systems in two respects: In a more general sense, CAAD also refers to the use of any computational technique in the field of architectural design other than by means of architecture-specific software. For example, software which is specifically developed for the computer animation industry (e.g. Maya and 3DStudio Max), is also used in architectural design. These programs can produce photo realistic 3d renders and animations. Nowadays real-time rendering
11536-436: The three primary spatial dimensions (width, height and depth), incorporating information about time (so-called 4D BIM), cost (5D BIM), asset management, sustainability, etc. BIM therefore covers more than just geometry. It also covers spatial relationships, geospatial information, quantities and properties of building components (for example, manufacturers' details), and enables a wide range of collaborative processes relating to
11648-611: The underlying hardware, rather than the contents stored on it, was denominated a "file". For example, the IBM 350 disk drives were denominated "disk files". The introduction, c. 1961 , by the Burroughs MCP and the MIT Compatible Time-Sharing System of the concept of a " file system " that managed several virtual "files" on one storage device is the origin of the contemporary denotation of
11760-403: The use of BIM for all government projects over HK$ 30M since 1 January 2018. India Building Information Modelling Association (IBIMA) is a national-level society that represents the entire Indian BIM community. In India BIM is also known as VDC: V irtual D esign and C onstruction. Due to its population and economic growth, India has an expanding construction market. In spite of this, BIM usage
11872-580: The user uses a disk editor to edit the file names in the directory entries . User applications, however, will usually not allow the user to create multiple files with the same name but differing in case. Most computers organize files into hierarchies using folders, directories, or catalogs. The concept is the same irrespective of the terminology used. Each folder can contain an arbitrary number of files, and it can also contain other folders. These other folders are referred to as subfolders. Subfolders can contain still more files and folders and so on, thus building
11984-402: The word. Although the contemporary " register file " demonstrates the early concept of files, its use has greatly decreased. On most modern operating systems , files are organized into one-dimensional arrays of bytes . The format of a file is defined by its content since a file is solely a container for data. On some platforms the format is indicated by its filename extension , specifying
12096-664: Was issued as a British Standard: BS 1192-4. In January 2019, ISO published the first two parts of ISO 19650, providing a framework for building information modelling, based on process standards developed in the United Kingdom. UK BS and PAS 1192 specifications form the basis of further parts of the ISO 19650 series, with parts on asset management (Part 3) and security management (Part 5) published in 2020. The IEC/ISO 81346 series for reference designation has published 81346-12:2018, also known as RDS-CW (Reference Designation System for Construction Works). The use of RDS-CW offers
12208-404: Was originally the type of program that architects used, but since CAD could not offer all the tools that architects needed to complete a project, CAAD developed as a distinct class of software . Use of terms in the field of computer design is not consistent. Caetano et al. analyzed the language of architectural research publications and noted the following trends: All CAD and CAAD systems employ
12320-566: Was reported by only 22% of respondents in a 2014 survey. In 2019, government officials said BIM could help save up to 20% by shortening construction time, and urged wider adoption by infrastructure ministries. The Iran Building Information Modeling Association (IBIMA) was founded in 2012 by professional engineers from five universities in Iran, including the Civil and Environmental Engineering Department at Amirkabir University of Technology . While it
12432-577: Was superseded in 2018 by Plan BIM 2022, administered by an industry body, the Association for the Development of Digital in Construction (AND Construction), founded in 2017, and supported by a digital platform, KROQI, developed and launched in 2017 by CSTB (France's Scientific and Technical Centre for Building ). In December 2015, the German minister for transport Alexander Dobrindt announced
12544-562: Was the CIMSteel Integration Standard, CIS/2, a product model and data exchange file format for structural steel project information (CIMsteel: Computer Integrated Manufacturing of Constructional Steelwork). CIS/2 enables seamless and integrated information exchange during the design and construction of steel framed structures. It was developed by the University of Leeds and the UK's Steel Construction Institute in
#54945